5. Cleaning, care and maintenance
f
f
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
f
f
Check the taps regularly. Limescale deposits at the tap out-
lets can be removed using commercially available descaling
agents.
f
f
Have the electrical safety of the appliance regularly checked
by a qualified contractor.
f
f
Regularly descale or replace the special aerator (see chapter
"Appliance description / Accessories").
6. Troubleshooting
Problem
Cause
remedy
The appliance will not
start despite the DHW
valve being fully open.
No power at the appli-
ance.
Check the fuse/MCB in
your fuse box/distribu-
tion board.
The aerator in the tap is
scaled up or dirty.
Clean and/or descale the
aerator or replace the
special aerator.
The water supply has
been interrupted.
Vent the appliance and
the cold water inlet line
(see chapter "Settings").
The required tempera-
ture is not being reached.
The maximum tempera-
ture set inside the appli-
ance is too low.
Have your qualified con-
tractor adjust the maxi-
mum temperature.
The appliance has
reached its output limit.
Reduce the flow rate.
If you cannot remedy the fault, notify your qualified contractor.