INSTaLLaTION
Specification
22
| EIL Premium
www.stiebel-eltron.com
15.2.3 EIL 7 Premium
2/PE ~ 380-400 V
L
L
L
p >
L
ϑ
V >
D
00000
35
30
9
1
2
3
1 Safety pressure limiter
2 Pressure differential switch
3 PCB with outlet temperature sensor
15.3 Temperature increase
At 230 V / 400 V, the following water temperature increases occur:
20,0
25,0
30,0
35,0
40,0
45,0
50,0
55,0
1,0
1,5
2,0
2,5
3,0
3,5
1
2
3
4
D
00000
82
71
9
X Flow rate in l/min
Y Temperature increase in K
1 3.5 kW - 230 V
2 4.4 kW - 230 V
3 5.7 kW - 230 V
4 6.5 kW - 400 V
Example EIL 3 Premium with 3.5 kW
Flow rate
l/min
2.0
Temperature increase
K
25
Cold water supply temperature
°C
12
Maximum possible outlet temperature
°C
37