Installation, Operation and Maintenance Manual – FMA 3000
Ref: 3000/T/6/VH
14
MODEL
3003
3004
3006
3008
3010
GENERAL FEATURES
Diameter Inlet/Outlet
(1)
DN-80 (3”)
DN-100 (4”)
DN-150 (6”)
DN-200 (8”)
DN-250 (10”)
Max./mín. working pressure
2 bar / 10 bar (please consult about others)
Max. fluid temperature
50 ºC
PVC MESH SUPPORT
Maximum flow rate (m
3
/h)
110
180
250
400
550
Gross filtering area (cm
2
)
2,450
4,800
7,200
9,600
12,000
Net filtering area (cm
2
)
1,600
3,200
4,800
6,400
8,000
Dry weight (kg)
60
75
90
131
164
Filtration sizes
1,000, 500, 300, 200, 125,100 microns
STAINLESS STEEL MESH
SUPPORT
Maximum flow rate (m
3
/h)
110
180
250
400
550
Gross filtering area (cm
2
)
2,450
4,800
7,200
9,600
12,000
Net filtering area (cm
2
)
1,600
3,200
4,800
6,400
8,000
Dry weight (kg)
62
80
98
142
179
Filtration sizes
1,000, 500, 300, 200, 125, 100 microns
BACKWASH
Backwash valve
G-2” Thread
Duration of wash cycle
20-40 seconds
Wash flow (m
3
/h)
3
6.5
14
23
28
Water consumption per wash
(liters)
25
49
110
178
238
ELECTRICAL DATA
Operating voltage
4 x 1.5 V LR 14-C batteries / (optional 220 V AC 50 Hz)
Control voltage
6 V DC / (24 V DC optional 220 V AC)
Содержание FMA-3000
Страница 5: ...Installation Operation and Maintenance Manual FMA 3000 Ref 3000 T 6 VH 5 ...
Страница 7: ...Installation Operation and Maintenance Manual FMA 3000 Ref 3000 T 6 VH 7 2 WARRANTY ...
Страница 17: ...Installation Operation and Maintenance Manual FMA 3000 Ref 3000 T 6 VH 17 ...
Страница 38: ...Installation Operation and Maintenance Manual FMA 3000 Ref 3000 T 6 VH 38 ...
Страница 39: ...Installation Operation and Maintenance Manual FMA 3000 Ref 3000 T 6 VH 39 ...