3.3 CobraNet 

 

3.3.1  CobraNet FAQ 
 

Q: How do CobraNet devices communicate on the network? Do they 
receive an IP address? 

A: CobraNet devices operate without the need for an IP address. Many 
configuration applications for CobraNet devices will assign an IP ad-
dress for organizational purposes. However, CobraNet devices operate 
using data channels called “bundles”. In order to connect a transmitter 
and a receiver in a CobraNet network, both devices simply need to be 
set to the same bundle number. There is no need for a DHCP server (a 
router for example).  

 

Q: How do I configure the bundles of the CVA50-1 NET+? 

A: Bundle settings should be configured using Cirrus Logic’s CobraNet 
Discovery Utility. Instructions for downloading and operation can be 
found in 

section 3.3.2

 

Q: Why is the CobraNet Discovery Utility not detecting any devices? 

A: First, ensure that your computer has an IP address. If you are operat-
ing without a DHCP server (ie in a switch-only network) then you will 
need to manually set an IP address in the Network Configuration sec-
tion of Windows. Next, go to Tools > Options in the top menu and 
make sure the proper network device is selected in the top dropdown.  

Q: Can the CVA50-1 NET+ transmit the input channels to other Cobra-
Net devices? 

A: No, the CVA50-1 NET+ is designed only to receive audio . 

Q: What submap channels do the CVA50-1 NET+ use? 

A: Since the CVA50-1 NET+ is a 2-channel device, only the first two 
submap channels are valid (channels 1 and 2). Data sent on channels 3-
8 will be ignored. 

  

3.3.2  Using CobraNet Discovery Utility 

 

The CobraNet Discovery utility can be downloaded from the Cirrus Log-
ic website at: http://www.cobranet.info/downloads/disco 
 
Once installed, it should be launched from a computer on the same 
network as the CVA50-1 NET+. After the program launches it will 
search for CobraNet devices. The CVA50-1 NET+ will appear as “Attero 
Tech CobraNet CEP2224”. If this is the first time you are setting up 
this device, or the device has been power cycled, the IP address will 
appear as 0.0.0.0. To set an IP address for easier recognition, right-click 
the device and select “Update IP Address”. To ensure visibility, assign 
it to the same subnet as the computer you are configuring it from. 
 

 

3.3.2  Setting Up Bundles 

 
To open up the bundle configuration window, double-click on the de-
vice listed in the screen above. You will see 2 Tx and 2 Rx bundles 
ready to configure. Do not configure the two Tx bundles. Single-click on 
each of the Rx bundles (shown as 300 and 301 in the screen capture 
on the next page) to make the fields editable. From here you can enter 
a new bundle numbers. 
 

Содержание CVA50-1 NET Series

Страница 1: ...CVA50 1 NET Series Owner s Manual June 2012 www stewartaudio com CVA50 1 NET CVA50 1 NET ...

Страница 2: ... sofa or similar surface that impedes airflow across the chassis Airflow around the unit should be unobstructed 4 This amplifier should not be used near water for example near a bathtub in a wet basement near a swimming pool etc This amplifier is intended to be operated in a controlled indoor environment 5 Do not place the amplifier near heat sources such as radiators heat regis ters stoves or oth...

Страница 3: ...s for connection and operation This manual provides you with the information necessary to safely in stall and operate your new CVA Series amplifier in the most common scenarios If you find yourself requiring additional assistance please feel free to contact your Authorized Dealer or you may contact us di rectly using the contact information provided on the back of this manu al Important Safety Ins...

Страница 4: ... which can be used with the AV Pole bracket available from Stewart Audio Two screws are included in the kit which will affix the bracket to the top or side of the unit 2 2 1 Universal Mount Installation The CVA Series also has a universal bracket available which allows the unit to be mounted against a wall or under a table Two screws are included in the kit which will affix the bracket to the top ...

Страница 5: ...r for its input connection This connector will accept both balanced or unbalanced connections however some modifications must be made for an unbalanced connection See the next two sections for instruc tions on connecting your amplifier to its input source 2 4 1 Balanced Input Connections When using a balanced input source and connector you must ensure that the hot cold and ground pins of the conne...

Страница 6: ...for error when connecting the CVA Series amplifier to an unbalanced source The summing adapters will properly sum a stereo source for use with the mono input on the rear of the amplifier without causing sound cancellation Part numbers are found below the diagrams 2 5 Output Connections Because of the differences in the way that constant voltage amplifiers work as opposed to a typical 8 ohm setup t...

Страница 7: ... will not be held responsible for damage to your CVA Series amplifier or connected equip ment if the instructions in this manual are not followed NOTE For additional operating precautions please refer to Important Safety Instructions located on Page 2 2 5 1 Constant Voltage The Euro Block connector on the rear of the amplifier is capable of sup plying output at either 100V or 70V depending on the ...

Страница 8: ...6 Speaker Out Connector CVA50 1 NET COBRANET PRIORITY NET LOC OUTPUT PWR 10V RVC GND MUTE RVC LINE OUT LOCAL IN SIG PWR CLIP LEVEL 100V 70V 1 1 2 3 5 6 7 4 1 Signal Priority Switch 2 CobraNet Connector 3 Channel Level Knob 5 Line Out 6 Remote Volume Control 7 Signal Present Indicator LED 4 Input Connector 8 Power Indicator LED 9 8 10 10 11 11 9 Clip Indicator LEDs 10 10 Power Connector 11 11 Speak...

Страница 9: ...mit the input channels to other Cobra Net devices A No the CVA50 1 NET is designed only to receive audio Q What submap channels do the CVA50 1 NET use A Since the CVA50 1 NET is a 2 channel device only the first two submap channels are valid channels 1 and 2 Data sent on channels 3 8 will be ignored 3 3 2 Using CobraNet Discovery Utility The CobraNet Discovery utility can be downloaded from the Ci...

Страница 10: ...nal If there is no signal detected check signal source and that level controls are set high enough Problem Amplifier overheats and or shuts off Procedure Review section 2 3 on proper cooling procedures Check the clip LED on the rear of the amplifier to see if the signal is overdriv ing the signal light flashes red frequently Overdriving the amplifier for extended periods of time can cause a therma...

Страница 11: ...nding to the fac tory for repair resulting in damage Any of the precautions or instructions found in this manual were not followed Damages resulting to the amplifier which are not covered under this warranty can be factory repaired at cost to the customer Use the con tact information below to initiate the repair process 6 2 Return Procedure This section includes the return procedures which must be...

Страница 12: ...si bility for damaged goods and or accessories that are sent with your unit 6 2 3 Packaging Instructions cont 1 Please write the RA number on three sides of the box Include the Stewart Audio RA number inside the box and a brief description of the problem 2 Do not ship any accessories manuals cords hardware etc with your unit These items are not needed to service your product Stewart Audio will not...

Страница 13: ...mbers shown are Stewart Audio Part Numbers To purchase these accessories or to see the full Stewart Audio product lineup visit us at www stewartaudio com Mounting Brackets AV POLE Pole mount bracket for AV Series amplifiers AV BRACKET Universal mounting bracket for AV Series amplifiers Connection Adapters ADPT RCA Mono Female RCA to male Euroblock ADPT SUMRCA Stereo Female RCA to male Euroblock AD...

Отзывы: