background image

2.4.2 Unbalanced Input Connections 

 
When using an unbalanced input source and connector, a jumper must 
be added between the negative (-) terminals and the ground terminals. 
Once this has been done, the unbalanced source can be connected to 
the positive (+) and ground terminals. Please refer to the manual of 
your input source in case it does not follow the standard pin-out. For 
your convenience, pre-wired connectors are available for purchase, see 
the next page for details. 

 

NOTE: A jumper is 

required

 for connecting an unbalanced 

input. 

 

NOTE: The CVA Series of amplifiers do not accept stereo 
inputs. Either one side must be selected from the stereo 
source or an overload-protected Y-cable must be used to 
sum them to mono. It is highly recommended that you 
purchase the pre-wired connectors mentioned on the next 
page. Damage to source equipment can result from the 

Pre-wired unbalanced connectors are available for purchase from Stew-
art Audio. These will allow for a quicker installation with less room for 
error when connecting the CVA Series amplifier to an unbalanced 
source. The summing adapters will properly sum a stereo source for 
use with the mono input on the rear of the amplifier without causing 
sound cancellation. Part numbers are found below the diagrams.

 

 
 
 
 
 
 
 
 
 
 
 
2.5 Output Connections 

Because of the differences in the way that constant-voltage amplifiers 
work as opposed to a typical 8-ohm setup, the wiring procedure and 
the gauge of wire used is very different.  
 
Constant voltage systems and speakers use a smaller current flow than 
the typical 8ohm systems and thus can use a higher gauge (thinner 
diameter) wire. Please refer to the following g chart to choose the ap-
propriate wire gauge for your installation. 
 
 
 
 
 
 
 
Speaker leads connect by means of removable Euro Block connectors 
supplied with the unit.  Strip speaker leads 1/4” and insert leads into 
connector observing proper polarity. With a small, flat-blade screwdriv-
er, tighten the screw until the leads are held securely in place. Inspect 
for possible shorts or broken wires. 

Distance Wire 

Gauge 

Up to 500ft 

22 AWG 

500-1000 ft. 

20 AWG 

Over 1000ft 

18 AWG 

ADPT-RCA 

Mono  

Female RCA 

ADPT-SUMRCA 

Stereo 

Female RCA 

ADPT-SUM35 

Stereo 

Female 3.5mm 

Содержание CVA50-1 NET Series

Страница 1: ...CVA50 1 NET Series Owner s Manual June 2012 www stewartaudio com CVA50 1 NET CVA50 1 NET ...

Страница 2: ... sofa or similar surface that impedes airflow across the chassis Airflow around the unit should be unobstructed 4 This amplifier should not be used near water for example near a bathtub in a wet basement near a swimming pool etc This amplifier is intended to be operated in a controlled indoor environment 5 Do not place the amplifier near heat sources such as radiators heat regis ters stoves or oth...

Страница 3: ...s for connection and operation This manual provides you with the information necessary to safely in stall and operate your new CVA Series amplifier in the most common scenarios If you find yourself requiring additional assistance please feel free to contact your Authorized Dealer or you may contact us di rectly using the contact information provided on the back of this manu al Important Safety Ins...

Страница 4: ... which can be used with the AV Pole bracket available from Stewart Audio Two screws are included in the kit which will affix the bracket to the top or side of the unit 2 2 1 Universal Mount Installation The CVA Series also has a universal bracket available which allows the unit to be mounted against a wall or under a table Two screws are included in the kit which will affix the bracket to the top ...

Страница 5: ...r for its input connection This connector will accept both balanced or unbalanced connections however some modifications must be made for an unbalanced connection See the next two sections for instruc tions on connecting your amplifier to its input source 2 4 1 Balanced Input Connections When using a balanced input source and connector you must ensure that the hot cold and ground pins of the conne...

Страница 6: ...for error when connecting the CVA Series amplifier to an unbalanced source The summing adapters will properly sum a stereo source for use with the mono input on the rear of the amplifier without causing sound cancellation Part numbers are found below the diagrams 2 5 Output Connections Because of the differences in the way that constant voltage amplifiers work as opposed to a typical 8 ohm setup t...

Страница 7: ... will not be held responsible for damage to your CVA Series amplifier or connected equip ment if the instructions in this manual are not followed NOTE For additional operating precautions please refer to Important Safety Instructions located on Page 2 2 5 1 Constant Voltage The Euro Block connector on the rear of the amplifier is capable of sup plying output at either 100V or 70V depending on the ...

Страница 8: ...6 Speaker Out Connector CVA50 1 NET COBRANET PRIORITY NET LOC OUTPUT PWR 10V RVC GND MUTE RVC LINE OUT LOCAL IN SIG PWR CLIP LEVEL 100V 70V 1 1 2 3 5 6 7 4 1 Signal Priority Switch 2 CobraNet Connector 3 Channel Level Knob 5 Line Out 6 Remote Volume Control 7 Signal Present Indicator LED 4 Input Connector 8 Power Indicator LED 9 8 10 10 11 11 9 Clip Indicator LEDs 10 10 Power Connector 11 11 Speak...

Страница 9: ...mit the input channels to other Cobra Net devices A No the CVA50 1 NET is designed only to receive audio Q What submap channels do the CVA50 1 NET use A Since the CVA50 1 NET is a 2 channel device only the first two submap channels are valid channels 1 and 2 Data sent on channels 3 8 will be ignored 3 3 2 Using CobraNet Discovery Utility The CobraNet Discovery utility can be downloaded from the Ci...

Страница 10: ...nal If there is no signal detected check signal source and that level controls are set high enough Problem Amplifier overheats and or shuts off Procedure Review section 2 3 on proper cooling procedures Check the clip LED on the rear of the amplifier to see if the signal is overdriv ing the signal light flashes red frequently Overdriving the amplifier for extended periods of time can cause a therma...

Страница 11: ...nding to the fac tory for repair resulting in damage Any of the precautions or instructions found in this manual were not followed Damages resulting to the amplifier which are not covered under this warranty can be factory repaired at cost to the customer Use the con tact information below to initiate the repair process 6 2 Return Procedure This section includes the return procedures which must be...

Страница 12: ...si bility for damaged goods and or accessories that are sent with your unit 6 2 3 Packaging Instructions cont 1 Please write the RA number on three sides of the box Include the Stewart Audio RA number inside the box and a brief description of the problem 2 Do not ship any accessories manuals cords hardware etc with your unit These items are not needed to service your product Stewart Audio will not...

Страница 13: ...mbers shown are Stewart Audio Part Numbers To purchase these accessories or to see the full Stewart Audio product lineup visit us at www stewartaudio com Mounting Brackets AV POLE Pole mount bracket for AV Series amplifiers AV BRACKET Universal mounting bracket for AV Series amplifiers Connection Adapters ADPT RCA Mono Female RCA to male Euroblock ADPT SUMRCA Stereo Female RCA to male Euroblock AD...