2.4.2 Unbalanced Input Connections
When using an unbalanced input source and connector, a jumper must
be added between the negative (-) terminals and the ground terminals.
Once this has been done, the unbalanced source can be connected to
the positive (+) and ground terminals. Please refer to the manual of
your input source in case it does not follow the standard pin-out. For
your convenience, pre-wired connectors are available for purchase, see
the next page for details.
NOTE: A jumper is
required
for connecting an unbalanced
input.
NOTE: The CVA Series of amplifiers do not accept stereo
inputs. Either one side must be selected from the stereo
source or an overload-protected Y-cable must be used to
sum them to mono. It is highly recommended that you
purchase the pre-wired connectors mentioned on the next
page. Damage to source equipment can result from the
Pre-wired unbalanced connectors are available for purchase from Stew-
art Audio. These will allow for a quicker installation with less room for
error when connecting the CVA Series amplifier to an unbalanced
source. The summing adapters will properly sum a stereo source for
use with the mono input on the rear of the amplifier without causing
sound cancellation. Part numbers are found below the diagrams.
2.5 Output Connections
Because of the differences in the way that constant-voltage amplifiers
work as opposed to a typical 8-ohm setup, the wiring procedure and
the gauge of wire used is very different.
Constant voltage systems and speakers use a smaller current flow than
the typical 8ohm systems and thus can use a higher gauge (thinner
diameter) wire. Please refer to the following g chart to choose the ap-
propriate wire gauge for your installation.
Speaker leads connect by means of removable Euro Block connectors
supplied with the unit. Strip speaker leads 1/4” and insert leads into
connector observing proper polarity. With a small, flat-blade screwdriv-
er, tighten the screw until the leads are held securely in place. Inspect
for possible shorts or broken wires.
Distance Wire
Gauge
Up to 500ft
22 AWG
500-1000 ft.
20 AWG
Over 1000ft
18 AWG
ADPT-RCA
Mono
Female RCA
ADPT-SUMRCA
Stereo
Female RCA
ADPT-SUM35
Stereo
Female 3.5mm