![Stevens Hydra Probe II Series Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/stevens/hydra-probe-ii-series/hydra-probe-ii-series_manual_1375858049.webp)
<quick>:
Quick mode, 1 character {‘1’ – ‘6’, ‘X’}
<warmup>:
Warmup time, 1-5 digits, 0-65535
<bool>:
Boolean value, 1 character, {‘0’ | ‘1’}
<firmware>:
Firmware, 3 or 4 bytes, formatted like “2.7” or “R2.7” or “2s7”
<text>
:
Printable ASCII text
<float>
:
Decimal number, optionally using a form of scientific notation.
Ex: “+23.54, 0.001, -123.0E5, 45.E-3”
<readings>:
Comma-delimited string of floats. Ex: “+23.54,-42.532,+2342.12”
Hydra Probe Specific RS-485 Commands
Information Commands
Serial Number
Description:
Returns
the factory serial number.
Access Level: Read only
Read Addresses: Broadcast, Exact
Read
Command:
<addr>SN=?<CR><LF>
Read
Response:
<addr><serial><CR><LF>
Firmware Version
Description: Returns the firmware version number.
Access Level: Read only
Read Addresses: Broadcast, Exact
Read
Command:
<addr>FV=?<CR><LF>
Read
Response:
<addr><firmware><CR><LF>
Standard Configuration Commands
Address
Description: Gets/sets the probe address.
Access
Level:
Read/Write
Read Addresses: Broadcast, Exact
Read
Command:
<addr>AD=?<CR><LF>
<addr><CR><LF>
Read Response:
Write Addresses: Exact
Write
Command:
<addr>AD=<serial><new_addr><CR><LF>
Write
Response:
<new_addr><CR><LF>
49