connected to a +12 volt power supply and the black and yellow wires should be connected to a
ground. For more information, refer to the data loggers operation manual. For DOTSET and the
Stevens DOT Logger refer to Appendix C.
3.2.2 SDI-12 Hydra Probe Wiring Connections
Table 2.2 and section 2.1 provide important information about the SDI-12 Hydra Probe. Connect
the red wire to a +12 volt DC power supply, connect the black wire to a ground, and connect the
blue wire to the SDI-12 port or the Data Logger. The SDI-12 data port on the Stevens DOT
logger is conveniently located on the right side of front face plate. The advantage of SDI-12
communications is that multiple probes can be connected to a single port on data logger. The
probes may be “daisy chained” together, or they may all be connected to a central terminal
assembly. The single SDI-12 data port on the DOT Logger can accommodate 150 SDI-12
Channels. To have 150 SDI-12 channels means that 50 probes set to measure soil moisture,
conductivity and temperature can all be wired together on a multiplexer with a single data wire
going into the single SDI-12 data port. For more information, refer to the data loggers operation
manual. For more information about the Stevens DOT Logger refer to Appendix C.
For more than 6 Hydra Probes, the user may find it easier to have the terminal assembly in a
separate enclosure from the logger, telemetry and power supply.
3.2.3 RS-485 Hydra Probe wiring Connections
Table 3.1 and section 2.1.4 provide important information about the RS-484 Hydra Probe.
Connect the red wire to a +12 volt DC power supply, and connect the black wire to a ground.
The green and white wires are the data wires.
Power Requirements
9 to 20 VDC (12VDC Ideal)
Red Wire
+Volts Power Input
Black Wire
Ground
White Wire
Data Signal A non-inverting signal
Green Wire
Data Signal B inverting signal
Baud Rate
9600
Power Consumption
<10 mA Idle 30 mA Active
Control system settings
8 DATA BITS
Control system settings
One Stop Bit
Control system settings
NO Parity
Table 3.1 Digital RS-485 Hydra Probe II Information.
Like SDI-12, the RS-485 communication format is also digital, therefore the probes’ data wires
can be “daisy chained” or connected together at a terminal assembly. See Appendix B for
RS-485 command structure.