Service and troubleshooting
Operating instructions (Version 0)
67
ST 1075
7
Note
n
In the event of malfunctions other than those described here, always consult
technical services.
Table 7.9
No battery power
Cause
Solution
No battery power.
Charge the batteries using the mains cable
supplied.
DO NOT USE AN EXTERNAL
BOOSTER CHARGER.
Have the batteries checked by a battery
specialist.
The main fuse has blown.
Check the main fuse above the batteries.
The mains switch is
OFF
.
Set the mains switch to
ON
.
Indicator lights and/or screen defective.
Contact technical services.
Table 7.10
No control voltage
Cause
Solution
Indicator lights and/or screen defective. Lifting
system functioning normally.
Contact technical services.
The lifting system may not be set up properly.
again, contact technical services.
A fuse has cut power to the controller.
The controller has multi-fuse circuit breakers.
After they have cooled down, they switch back
on again automatically. If the fault occurs again,
contact technical services.
The mains switch is
OFF
.
Set the mains switch to
ON
.
Содержание ST1075-FBF
Страница 21: ...Safety Operating instructions Version 0 21 ST 1075 2 Figure 2 2 Safety and warning labels ...
Страница 78: ...Operating instructions Version 0 78 ST 1075 A 2 Hydraulic unit Figure A 2 Hydraulic unit ...
Страница 85: ...List of parts and appendices Operating instructions Version 0 85 ST 1075 A Figure A 5 3 Control box ...
Страница 90: ...Operating instructions Version 0 90 ST 1075 A 9 Label locations Figure A 9 Label locations ...
Страница 100: ...Operating instructions Version 0 100 ST 1075 Date Remarks Name of mechanic Initials of mechanic pass ...