Stern TUBULAR 1000 B Скачать руководство пользователя страница 20

18

15 Gan Rave Blvd., 81222 Gan Rave, Yavne, Israel

Tel: 972-8-9326000, Fax: 972-8-9326025, [email protected]

www.sternfaucets.com

07.09     015350800

Содержание TUBULAR 1000 B

Страница 1: ...1 INSTALLATION AND MAINTENANCE GUIDE WALL MOUNTED ELECTRONIC FAUCET WITH MIXER TUBULAR 1000 SERIES TUBULAR 1000 SERIES Tubular 1000 B Tubular 1000 E Tubular 1000 B Box Tubular 1000 E Box...

Страница 2: ...000 E 8 11 Tubular 1000 B Box and Tubular 1000 E Box 12 SETTINGS ADJUSTMENT 13 BATTERY REPLACEMENT INSTRUCTIONS To replace the battery at Tubular 1000 B and Tubular 1000 B Box models 14 MAINTENANCE Fi...

Страница 3: ...r electricity versions Recommended water pressure Sensor range Minimum sensor range Maximum sensor range Security time Hot water temperature 9V battery or 6 x 1 5 V AA batteries 9V transformer 0 5 8 0...

Страница 4: ...B 1000 E Spout and attachments incl electronic unit Tubular base Wall rosette M4x6 setscrew 2 x Solenoids and housings with filters and filter adaptors Power splitter IP 67 Battery box Transformer B V...

Страница 5: ...all rosette M4x6 screw TUBULAR 1000 B BOX 1000 E BOX Rigid pipes Box mounting pack incl solenoid valves and filters 4 x Screws Permanent panel Temporary protective cover 2 x Angle supports Battery box...

Страница 6: ...o not attempt to install your electronic faucet until you obtain the missing parts Preparation for installation Flush the water supply lines thoroughly before installing the faucet Do not allow dirt T...

Страница 7: ...nal nut and the disk 5 Connect the cable leading to the solenoid and the cable leading to the power supply at the spout to those at the Tubular base 6 Insert the flexible hoses from inside the wall th...

Страница 8: ...olenoid housings and the water inlets Before proceeding to step 3 check that no objects are in front of the sensor besides the washbasin Remove now the protecting sticker that covers the sensor the so...

Страница 9: ...mer wait about 10 seconds in order to allow the system to set the ideal sensor range Then the product will be ready for use 3 Turn on the central water supply Check for leaks Note Tubular includes a s...

Страница 10: ...re you want to install the spout 3 Insert theTubular boxthrough the wall Connect the water supply pipe to the nipple at the bottom of the Tubular box Installation instructions for TUBULAR 1000 B BOX T...

Страница 11: ...you cut it 7 Assemble the temporary panel to the Tubular box 8 Once the works on electricity plumbing and tiles have been finished cut the temporary protective cover at the proper mark at the wall le...

Страница 12: ...t automatically Check that no objects are in front of the sensor besides the washbasin Remove now the protecting sticker that covers the sensor Step 2 Connecting the power source 1 If your model is Tu...

Страница 13: ...of the water stream simply move the adjustable tilting plate by pressing it smoothly 3 If the automatically adjusted sensor range is not satisfactory to your purposes please refer to the section entit...

Страница 14: ...crease detection range and to decrease the detection range of the sensor Adjusting other settings with the remote control Flow time Security time Press to increase the security time and to decrease it...

Страница 15: ...box 2 For Tubular 1000 B Box Release the screws at the panel and remove it The battery box is located behind the panel Open carefully the battery s box and replace the used battery with a new 9V batt...

Страница 16: ...solenoid valves by opening the nuts c Remove the filters and wash them under running water d Reassemble the filters e Reassemble the solenoid valves f Turn on the regulating valve and adjust the flow...

Страница 17: ...ttery box for 1 x 9V battery IP67 Transformer box with transformer Transformer junction box Transformer junction box exit with 3 meter cable and male connector Mixing valve Cat No 07220056 Cat No 0750...

Страница 18: ...4 The water supply pressure is higher than 8 bar Debris or scale in diaphragm 1 Sensor is dirty or covered 2 Sensor is picking up reflections from the washbasin or another object Filter or aerator is...

Страница 19: ...may arise see Stern Warranty The guarantee does not cover faults or damage caused by incorrect installation and or maintenance wear and tear battery or water composition This includes but is not limi...

Страница 20: ...18 15 Gan Rave Blvd 81222 Gan Rave Yavne Israel Tel 972 8 9326000 Fax 972 8 9326025 export sternfaucets com www sternfaucets com 07 09 015350800...