Stern D28 BOX Скачать руководство пользователя страница 5

6

7

sTeP 1 - iNsTalliNg The fauceT

1. Shut off the water supply 
2. Drill a hole (26 to 27 mm) at the place where you want to install the faucet spout. 
3. Your model includes an optional anti-rotation pin. Drill a small hole just above the     

    previous one for the anti-rotation pin. 

4. Insert the faucet and its attachments through the wall. The aerator in the faucet 

     spout  must face the washbasin. 
5. Insert the anti-rotation pin into the small hole (if needed) 
6. Fix the base behind the wall with the hexagonal nut and the disk.

sTeP 2 -  coNNecTiNg The waTer suPPly

1.

 fit the flexible pipe coming from the 

faucet

      

    base to the solenoid valve housing. 

2. Fit the water supply inlet to the inlet nipple at 

    the solenoid valve housing. 

note:

 Make sure the filter is located at the 

solenoid inlet. 
3. Connect the cable coming from the electronic 

    unit to the solenoid valve. 

important: 

The faucet was supplied with a self 

adjusting sensor. The ideal sensor range for the 

specific location will be set automatically.

iNsTallaTioN

iNsTallaTioN

D28 | D28 e 

D28 | D28 e 

Before proceeding to step 3 check that no 

objects are in front of the sensor besides 

the washbasin. 

Now, remove the protecting sticker that 

covers the sensor.

sTeP 3 – coNNecTiNg The Power source

1.  For D28: Connect the other cable coming from the electronic unit at the D28 base 

to the battery box. 

2. For D28 E: Connect the other cable coming from the electronic unit at the D28 base 

to the transformer. Plug the transformer into the electricity socket. 

3. After you have connected the power source 

(battery or transformer) wait 15 seconds in 

order to allow the system to set the ideal 

sensor range. As an indication that the self 

adjusting is taking place, a LED in the sensor 

eye will flash continuously. 

The solenoid 

valve will be opened and closed for 

1 second as an indication that the ideal

sensor range was set and the product is 

ready for use. 

4. Turn on the central water supply. Check for leaks. 

5. If the automatically adjusted sensor range is not satisfactory, please refer to the 

section entitled “Settings adjustment”.

Содержание D28 BOX

Страница 1: ...1 1 Installation and maintenance guide D28 series Wall mounted electronic faucet for cold or premixed water D28 D28E d28 dual power b d28 dual power E d28 box D28 E Box...

Страница 2: ...ing Stern Engineering Ltd reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials and other spec...

Страница 3: ...cl electronic unit M 4 x 4 set screw 1 x Wall rosette 1 x D28 base 1 x Corrugated Tube 1 x Dual power input box with inlet nipple and filter b VERSIONS E VERSIONS 1 x Dual power input box with inlet n...

Страница 4: ...of the sensor 1 x Box assembly with concealed solenoid valve 1 x Mud guard cover 1 x Spout and attachments incl electronic unit M 4 x 4 set screw 1 x D28 base 1 x Wall rosette 1 x Panel Screw M 3 x 6...

Страница 5: ...sor range for the specific location will be set automatically Installation Installation D28 D28 E D28 D28 E Before proceeding to step 3 check that no objects are in front of the sensor besides the was...

Страница 6: ...the flexible tube through the corrugated tube 10 Connect the flexible tube to the solenoid valve body integrated in the dual power input box See FIG 3 11 Connect the water tube coming from the faucet...

Страница 7: ...tube at the D28 base to the transformer See FIG 5 12 Connect the solenoid valve cable and the power supply cable from the spout to those at the D28 base 13 Fix the D28 spout by inserting the nipple i...

Страница 8: ...ntil a quick flashing of the LED in the sensor eye is perceived Then press to increase the range and to reduce it Every push will increase or decrease one level Note Once you have changed the detectio...

Страница 9: ...change the delay in time for flush valves for urinals or toilets only If required the delay in time can also be modified in faucets as follows Press the IN button Wait until a quick flashing of the LE...

Страница 10: ...w 9V battery Lithium battery is recommended Close the box and re assemble the wall cover panel Important D28 is supplied with a self adjusting sensor The ideal sensor range for the specific location w...

Страница 11: ...06530080 9V Transformer EU plug 06522091 Remote Control 13B Optional 07100005 Soap Water Remote Control Optional 07100014 Spare pares d28 dual power Seals Screws Kit 07210102 10 Pack Sensor Kit 08004...

Страница 12: ...r aerator is clogged Water flow diminished Troubleshooting Security Mode If the sensor is covered for more than 90 sec the faucet will automatically shut off water flow To return to normal operation r...

Страница 13: ...12 19 015352000 D 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Отзывы: