Technical daTa

2

1

     TECHNICAL DATA

2-4 

     PACK CONTENTS

     PRE-INSTALLATION INFO

6-11 

     FAUCET INSTALLATION

12-14            SETTINGS ADJUSTMENT

15 

     MAINTENANCE

Filters cleaning instructions 

Care and cleaning of chrome and special finishes 

16                 BATTERY REPLACEMENT

17-19       SPARE PARTS LIST

20 

     TROUBLESHOOTING

21 

     LIMITED WARRANTY

iNDeX

TechNical DaTa

Power supply

D28 model -

 

6x1.5V batteries

D28 Box B model - 9V Lithium battery

D28 Dual Power B model -9V Alkaline battery

D28E models - 9V transformer 

Recommended water 

pressure

0.5-8.0 bar (7-116 PSI) With water pressure of more than 

8 bars, use a pressure reducing valve for reduction.

Preset sensor range

Self-adjusting sensor

Minimum sensor range

35mm / 1.38”

Maximum sensor 

range

300mm / 11.81”

Security time

90 seconds. Can be reduced with optional 

remote control.

hot water temperature

Max 70°C

352000

D28

352100

D28E

352300

D28 DUAL POWER B

352400

D28 DUAL POWER E

352200

D28 BOx B

352500

D28 BOx E

the information in this document reflects products at the date of printing. stern engineering ltd  reserves the right,  subject to all applicable laws, at any time, at its sole discretion, 

and without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the 

forgoing from the market. all information in this document is provided “as is” without warranty of any kind, either expressed or implied, including but not limited to any implied 

warranties of merchantability, fitness for a particular purpose, or non-infringement. stern engineering ltd  assumes no responsibility for errors or omissions in the information 

presented in this document. In no event shall stern engineering ltd  be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever 

arising out of or in connection with the use or performance of this information. the tradenames, trademarks, logos and service marks presented in this document, including their 

design, are the property of stern engineering ltd or other third parties and you are not permitted to use them without the prior written consent of stern engineering ltd  or such 

third party as may own them.

Содержание D28 BOX

Страница 1: ...1 1 Installation and maintenance guide D28 series Wall mounted electronic faucet for cold or premixed water D28 D28E d28 dual power b d28 dual power E d28 box D28 E Box...

Страница 2: ...ing Stern Engineering Ltd reserves the right subject to all applicable laws at any time at its sole discretion and without notice to discontinue or change the features designs materials and other spec...

Страница 3: ...cl electronic unit M 4 x 4 set screw 1 x Wall rosette 1 x D28 base 1 x Corrugated Tube 1 x Dual power input box with inlet nipple and filter b VERSIONS E VERSIONS 1 x Dual power input box with inlet n...

Страница 4: ...of the sensor 1 x Box assembly with concealed solenoid valve 1 x Mud guard cover 1 x Spout and attachments incl electronic unit M 4 x 4 set screw 1 x D28 base 1 x Wall rosette 1 x Panel Screw M 3 x 6...

Страница 5: ...sor range for the specific location will be set automatically Installation Installation D28 D28 E D28 D28 E Before proceeding to step 3 check that no objects are in front of the sensor besides the was...

Страница 6: ...the flexible tube through the corrugated tube 10 Connect the flexible tube to the solenoid valve body integrated in the dual power input box See FIG 3 11 Connect the water tube coming from the faucet...

Страница 7: ...tube at the D28 base to the transformer See FIG 5 12 Connect the solenoid valve cable and the power supply cable from the spout to those at the D28 base 13 Fix the D28 spout by inserting the nipple i...

Страница 8: ...ntil a quick flashing of the LED in the sensor eye is perceived Then press to increase the range and to reduce it Every push will increase or decrease one level Note Once you have changed the detectio...

Страница 9: ...change the delay in time for flush valves for urinals or toilets only If required the delay in time can also be modified in faucets as follows Press the IN button Wait until a quick flashing of the LE...

Страница 10: ...w 9V battery Lithium battery is recommended Close the box and re assemble the wall cover panel Important D28 is supplied with a self adjusting sensor The ideal sensor range for the specific location w...

Страница 11: ...06530080 9V Transformer EU plug 06522091 Remote Control 13B Optional 07100005 Soap Water Remote Control Optional 07100014 Spare pares d28 dual power Seals Screws Kit 07210102 10 Pack Sensor Kit 08004...

Страница 12: ...r aerator is clogged Water flow diminished Troubleshooting Security Mode If the sensor is covered for more than 90 sec the faucet will automatically shut off water flow To return to normal operation r...

Страница 13: ...12 19 015352000 D 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Отзывы: