background image

12

TroublEshooTINg

* “Security Mode”: If the sensor is covered for more than 90 sec. the faucet will automatically shut off 

water flow. 

To return to normal operation remove any blockage.
** In this case, the water flow will stop anyway after 90 seconds because of the security time.

soluTIoN

causE

 INDIcaTor

 ProblEm

Replace battery

Low battery.

1. Sensor flashes 

continuously 

when user’s 

hands are within 

the sensor’s 

range.

No water 

coming out 

of the faucet:

Increase the range

1. Range is too short.

2. LED in the 

sensor does not 

flash once when 

user’s hands   

are within the 

sensor’s range.

Decrease the range

2. Range is too long.

The battery must be replaced. 

3. Battery is completely used up 
4. Unit is in “Security Mode”*

Eliminate cause of reflection. 

5. Sensor is picking up reflections from the 

washbasin or another object.

Connect the electronic unit 

connectors to the solenoid.

1. Connectors between the electronic unit 

and solenoid are disconnected.

3. LED in the 

sensor flashes 

once when 

user’s hands 

are within the 

sensor’s range.

Unscrew solenoid, pull out the 

plunger and the spring from 

the solenoid and clean them. 

Use scale remover material if 

needed. When replacing the 

plunger, please make sure that 

the spring is in vertical position. 

2. Debris or scale in solenoid.

Clean the orifice or replace 

diaphragm. 

3. The central orifice in the diaphragm is 

plugged or the diaphragm is torn

Reduce the supply water 

pressure.

4. The water supply pressure is higher than 

8 bar.

Shut off water supply and 

unscrew one of the flexible 

pipes in order to reduce the 

pressure that blocks the 

product.

5. The water supply pressure is under 8 bars 

and yet the pressure in the faucet’s body is 

higher. This situation could be caused by a 

sudden increase in the water supply pressure 

that the back check prevents from dropping, 

even after water supply pressure drops under 

8 bars.

Clean the orifice or replace 

diaphragm. 

1. Debris or scale in diaphragm

1. Sensor flashes 

once when 

user’s hands 

are within the 

sensor’s range. 

Water flow 

from spout 

does not 

stop:

Clean or eliminate case of 

interference.

1. Sensor is dirty or covered.**

2. LED in the 

sensor does not 

flash once when 

user’s hands 

are within the 

sensor’s range.

Decrease the range or eliminate 

cause of reflection. 

2. Sensor is picking up reflections from the 

washbasin or another object.

Remove, clean, re-install

Filter or aerator is clogged

Water flow 

diminished

Содержание CSABA 1000 B 233020

Страница 1: ...1 I n sta l l at i o n a n d m a i n t e n a n c e g u i d e ELECT RONIC LAVATORY FAUCET csaba series...

Страница 2: ...cument is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infring...

Страница 3: ...ial If any parts are missing do not attempt to install your electronic faucet until you obtain the missing parts Warnings Do not install facing a mirror or any other electronic system operated by an i...

Страница 4: ...Dual Power Input Box 1 nut 2 installation installation STEP 3 Connecting the water supply NOTE Flow direction is denoted by the arrow on the solenoid housing 1 Connect the Nipple and FILTER on the in...

Страница 5: ...nsor range was set and the product is ready for use Security time The Security time prevents continuous running of water due to reflections or vandalism By default if the sensor is covered for more th...

Страница 6: ...red press the Reset button and without releasing it press the button once Note To enter the self adjusting mode use the ADJ button To change the sensor range use the RANGE button SETTINGS adjustment M...

Страница 7: ...ted above In no event shall the liability of Stern Engineering Ltd exceed the purchase price of the product If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumb...

Страница 8: ...d clean them Use scale remover material if needed When replacing the plunger please make sure that the spring is in vertical position 2 Debris or scale in solenoid Clean the orifice or replace diaphra...

Страница 9: ...14 11 19 01500477 B 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Отзывы: