background image

8

9

DELAY IN TIME: It is recommended to change the delay in time for 

flush valves for urinals or toilets only. 

If required, the delay in time can also be modified in faucets as 

follows:
Press the IN button. Wait until a quick flashing of the LED in the 

sensor eye is perceived. Then, press + to increase the delay in 

time and – to reduce it.

DELAY OUT TIME: This button allows modifying the water flow 

time after the user removes his hands from the faucet. A delay out 

time close to 0 will save more water. An increased delay out time 

will make the user experience more comfortable.  

If required, the delay out time can be modified as follows:
Press the OUT button. Wait until a quick flashing of the LED in the 

sensor eye is perceived. Then, press + to increase the delay out 

time and – to reduce it.

24 HOUR HYGIENE FLUSH: This model includes a 24 hours hygiene 

flush which is disabled. To activate the hygiene flush, press the 

clock button. Wait until a quick flashing of the LED in the sensor eye 

is perceived. Then press + to activate the hygiene flush. To disable 

it again, press – to deactivate it. 

COMFORT FLUSH: If your model includes a Comfort flush setting, it 

can be activated by pressing the flush button. 
When the button is pressed, one blink of the LED in the sensor eye 

is perceived. The pre-programmed flush cycle will take place then.

The Comfort flush cannot be interrupted or deactivated by pressing 

any button until it is over.

TEMPORARY OFF FUNCTION: This function is ideal to perform any 

kind of activity in front of the sensor without operating the system 

(for example, cleaning). 

The faucet will remain shut for 1 minute when this button is 

pressed once. To cancel this function and to return to normal 

operation press the On/Off button again or wait 1 minute.

RESET BUTTON: This function restores all the factory settings 

except for the sensor range. If required, press the Reset button 

and without releasing it, press the + button once.

note: 

To enter the self adjusting mode, use the ADJ button. To change the sensor 

range, use the RANGE button.

sETTINgs aDjusTmENT

maINTENaNcE

Battery models only

When the battery weakens, the LED will blink at a constant rate when the user’s hands 

are within the sensor range. The battery must be replaced within two weeks.
Always use batteries from a reputable source. Poor quality batteries may affect the 

performance of the product. 

to replace the battery:

Carefully open the dual power input box using the Allen key provided. Remove the old 

battery and replace it with a new 9V battery (Lithium battery is recommended). Close 

the box lid and tighten it with the screw.

important: 

Spent batteries should not be disposed of with normal 

household waste. Contact your local authority for information on waste 

disposal and recycling. 

baTTEry rEPlacEmENT

filter cleaning instructions

This tap is provided with a stainless steel filter preventing foreign particles to enter the 

lines. If the water flow has decreased, this may be because the filter is clogged. The 

filter can be cleaned as follows:
1. Shut-off the water shut off valve. 
2. Disconnect the water supply pipe from the adaptor and disassemble the filter from it. 
3. Wash the filter under running water.
4. Reassemble the parts.
5. Restore the incoming water supply. 
6. Make sure that there is no water leakage. 

Care and cleaning of chrome and special finishes

DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the 

like. Use of any prohibited cleaning or maintenance products or substances could 

damage the surface of the faucet. For surface cleaning of faucet us ONLY soap and 

water, then wipe dry with clean cloth or towel. When cleaning bathroom tile, the faucets 

should be protected from any splattering of harsh cleansers.

If system chemical disinfection is practiced, chlorine can be used (calculated chlorine 

concentration of 50mg/l maximum in water per one hour dwell time) at service interval 

frequency.

Содержание CSABA 1000 B 233020

Страница 1: ...1 I n sta l l at i o n a n d m a i n t e n a n c e g u i d e ELECT RONIC LAVATORY FAUCET csaba series...

Страница 2: ...cument is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular purpose or non infring...

Страница 3: ...ial If any parts are missing do not attempt to install your electronic faucet until you obtain the missing parts Warnings Do not install facing a mirror or any other electronic system operated by an i...

Страница 4: ...Dual Power Input Box 1 nut 2 installation installation STEP 3 Connecting the water supply NOTE Flow direction is denoted by the arrow on the solenoid housing 1 Connect the Nipple and FILTER on the in...

Страница 5: ...nsor range was set and the product is ready for use Security time The Security time prevents continuous running of water due to reflections or vandalism By default if the sensor is covered for more th...

Страница 6: ...red press the Reset button and without releasing it press the button once Note To enter the self adjusting mode use the ADJ button To change the sensor range use the RANGE button SETTINGS adjustment M...

Страница 7: ...ted above In no event shall the liability of Stern Engineering Ltd exceed the purchase price of the product If you believe that you have a warranty claim contact your Stern Distributor Dealer or Plumb...

Страница 8: ...d clean them Use scale remover material if needed When replacing the plunger please make sure that the spring is in vertical position 2 Debris or scale in solenoid Clean the orifice or replace diaphra...

Страница 9: ...14 11 19 01500477 B 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Отзывы: