background image

10

11

9.  Electrical Wiring

 

      

Caution:

 assure that the 

transformer is not connected  

 

to the main power line. 

  Do not perform any electrical wiring  

  under power.

  Connect the power (transformer)    

  to the faucet electrical connector   

      and the soap dispenser electrical

  connector using the power splitter.

 

  Connect the soap dispenser pump  

  connector to its matching connector  

  coming from the electronic unit.    

  Please note that since the connector  

  is waterproof, some friction might  

  have to be applied.

 Important: 

The 4 contacts connector  

  should be connected properly so that  

  the white o-ring is not visible and 

  a clicking sound is heard.

INSTALLATION

INSTALLATION

F1

10.  Powering and Testing the System

Important Note: The 

D28/

TUBULAR/QUADRAT

 faucet 

and soap dispenser system 

include the self-adjusting  

 

sensors. The ideal sensor range 

 

for the specific location will be set  

 automatically.

 

Before proceeding, check that there  

 

are no foreign objects in front of the  

 sensors.

 

Remove the protective stickers that  

 

cover the sensors, both on the faucet  

 

and on the soap dispenser.

 

Plug in the transformer to the main  

 

power line. 

 

Wait about 10 seconds for the faucet  

 

and the soap dispenser sensors to  

 

complete their self-adjustment.

 

Put your hands under the Faucet   

 

and the Soap Dispenser and verify  

 

their functionality.

O-RING VISIBLE – NOT CONNECTED PROPERLY 

ONLY THE GROVES ARE VISIBLE – CONNECTED PROPERLY

10

SECONDS

To Soap Dispenser

To Faucet

To Power

Caution

: If the 4 contacts connectors are not connected properly, the pump 

will work continuously

OBJECT

F2

Содержание D28 500100

Страница 1: ...1 INSTALLATION AND MAINTENANCE GUIDE INSTALLATION AND MAINTENANCE GUIDE D28 TUBULAR QUADRAT SOAP WATER KE SYSTEM D28 TUBULAR QUADRAT...

Страница 2: ...re installing the faucet Do not allow dirt Teflon tape or metal particles to enter the faucet Shut off water supply when done Notes Cautions Cautions 1 PRE INSTALLATION 2 3 PACK CONTENTS 4 TECHNICAL D...

Страница 3: ...VE OPTIONAL QTY QTY 1 1 SOAP BOTTLE SOAP BOTTLE AND BRACKET AND BRACKET QTY QTY 1 1 SCREW ANCHOR SCREW ANCHOR FOR SOAP BOTTLE FOR SOAP BOTTLE BRACKET BRACKET QTY QTY 2 2 DUAL POWER DUAL POWER INPUT BO...

Страница 4: ...ng sensor Adjustable by remote control Sensor range soap dispenser 30 100 mm 10 mm Adjustable by remote control Soap capacity 1 Liter 33 8 oz Soap viscosity 100 3800 CPS Standard soap discharge 1 4 cc...

Страница 5: ...ollowing parts will protrude out of the wall Faucet and Soap Dispenser bases with dust covers C1 NOTE It is recommended to fill the cavities around the base with cement to better secure it inside the...

Страница 6: ...nd one water Inlet flexible tube The soap dispenser has two electrical wires and one soap inlet flexible tube and these wires and pipes will be connected at a later stage 7 Connecting the water supply...

Страница 7: ...esting the System Important Note The D28 TUBULAR QUADRAT faucet and soap dispenser system include the self adjusting sensors The ideal sensor range for the specific location will be set automatically...

Страница 8: ...t of the recommended range too close or too far will not operate The remote control can be used to adjust the following functions 1 SOAP QUANTITY The 1 4 drop keys allow the user to choose the desired...

Страница 9: ...Wait until a quick flashing of the LED in the sensor eye is perceived Then press to increase the range and to reduce it Every push will increase or decrease one level Note Once you have changed the d...

Страница 10: ...Press the IN button Wait until a quick flashing of the LED in the sensor eye is perceived Then press to increase the delay in time and to reduce it DELAY OUT TIME This button allows modifying the wat...

Страница 11: ...e whether performed by a contractor service company or the consumer This warranty does not cover product damage caused by the following Incorrect installation inversions of supply pipes Pressures or t...

Страница 12: ...the sensor does not flash once when user s hands are within the sensor s range No water is coming out of the faucet Decrease the range 2 Range is too long 3 Unit is in Security Mode Eliminate the caus...

Страница 13: ...22 03 20 01500462 B 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com sternusa sternfaucets com...