AC input 100-240v 50/60hz 1.5 amp max
Maximum Output Charging Current 5A d/c for 12 v and 2.2 A d/c for 24 v
Max. Power 70 watts
Efficiency >78%
Battery Voltage to Trigger Sot Start Bulk Charge Mode 6V < Vbat<10V
Soft Start Bulk Charge Current Level (Current Limit) 2.5 amps
Protection: Overload, Short Circuit ,
Over Temperature, Reverse Polarity,
No Spark Battery Connected and
Short circuit .
Cooling System Natural Convection
Approvals CE EN55014 EN60335 EN50366
Dimensions (L150 x W60 x D30 mm)
Specifications are subject to change and improvement without prior notice
WARNING
For indoor use only.
Explosion hazard:
A battery being charged could emit explosive gases. Avoid smoking, open sparks or
naked flames in the vicinity of the battery being charged.
Danger of explosion and fire:
While charging, explosive and flammable substances such as fuel or
solvents should not be kept in the vicinity of the charger or the battery. Do not cover the charger while
charging.
Danger of chemical burns:
Battery acid is highly corrosive. lf your skin or eyes come into contact with acid,
immediately rinse the effected part of the body with excessive water and seek medical advice.
Do not charge a frozen battery or non re-chargable batteries.
Do not charge a damaged battery.
Before charging, make sure the input is within rating level, otherwise charging performance may be seriously
effected.
While connecting the charger to the battery, maintain the correct polarity connection and avoid short
circuiting the battery cables.
Disconnect the battery from the charger when the charger is not connected to the a/c power supply. This will
reduce back drain current.
Do not recharge non-rechargeable batteries. only charge batteries for which the charger was designed
During charging, the battery must be placed in a ventilated area.
The supply cord cannot be replaced. lf the cord is damaged the charger should be scrapped.
When charging automotive batteries:
the battery terminal not connected to the chassis has to be
connected first. ( in most case this is the positive ). After charging, disconnect the battery charger trom the
mains. Then remove the chassis connection and then battery connection.
Warrantee: 2 year return to factory, see
or
for return
address
www.sterling-power.com