1.
General Operation:
When the system is operating,
one of the three displays may be shown. Pressing
NEXT
will alternate between displays. One of the displays
is always the current time of day. The second display
is one of the following: days remaining or volume
remaining. Days remaining is the number of days left
before the system goes through a regeneration cycle.
Capacity remaining is the gallons that will be treated
before the system goes through a regeneration cycle.
The third display shows the current treated water flow
rate through the system in Gallons Per Minute. The
user can scroll between the displays as desired.
If the system has called for a regeneration that will
occur at the preset time of regeneration, the words
REGEN TODAY will appear on the display.
If a water meter is installed, the word "Softening" or "Filtering" flashes on the display when water
is being treated (i.e. water is flowing through the system).
2.
Regeneration Mode:
Typically a system is set to regenerate at a time of
no water use. If there is a demand for water when the system is
regenerating, untreated water will be delivered. When the system begins to
regenerate, the display will change to include information about the step of
the regeneration process and the time remaining for that step to be
completed. The system runs through the steps automatically and will reset
itself to provide treated water when the regeneration has been completed.
3.
Manual Regeneration:
Sometimes there is a need to
regenerate before the control valve calls for it. This may be
needed if a period of heavy water use is anticipated or when the
system has been operated without salt.
● To initiate a manual regeneration at the preset delayed
regeneration time, press and release
REGEN
. The words
"REGEN TODAY" will flash on the display to indicate that
the system will regenerate at the preset delayed regeneration time.
● If you pressed the
REGEN
button in error, pressing the button again will cancel the
command.
● To initiate a manual regeneration immediately, press and hold the
REGEN
button for three
seconds. The system will begin to regenerate immediately. This command cannot be
cancelled.
4.
Power Loss:
If the power goes out for less than two hours, the
system will automatically reset itself. If an extended power outage
occurs, the time of day will flash on and off which indicated the time
of day should be reset.
The system will remember all other settings.
Error Message:
If the word "ERROR" and a number are alternately
flashing on the display record the number and contact the dealer for help.
This indicates that the control valve was not able to function properly.
MANUAL REGENERATION
POWER LOSS OR ERROR
OPERATING DISPLAYS FOR WATER SOFTENERS & BACKWASHING FILTERS:
GENERAL OPERATION DISPLAYS
MODE
REGENERATION
REGEN TODAY will flash
if a regeneration is
expected "tonight"
10