On  first  start  up  all  LEDs  will  light  up. A  beep  should 
sound.  The  fan  shall  then  start  running  for  around  5 
seconds. If, after this, 2 red LEDs flash for 8 seconds 
you may have a calibration issue and the unit should be 
returned to Sterling. If 2 solid red LEDs are on at the top 
or bottom then you either have high or low input voltage 
(respectively) - check your voltages.

Changing charging profile during startup

After the initial start up an LED on the left panel shall 
light up for 5 seconds, this shall indicate the battery type 
selected  - 

default  is  sealed  lead  acid

.  This  is  your 

window of opportunity to change the charging profile. If 
you have missed the opportunity, you can wait for the 
unit  to  go  in  to  normal  operation  and  follow  the 
instructions on the right of the page or restart the device.

Hold  down  both  buttons  on  the  front  panel  (SELECT 
and  SETUP/ENTER)  for  more  than  10  seconds  (less 
than 20 seconds!). All LEDs on the left column shall now 
flash.  By  using  these  two  buttons  toggle  through  the 
various profiles (see below). The right button is up the 
column and the left button takes you down the column. 
The LED shall light up demonstrating which profile you 
have selected. When the LED has illuminated at your 
desired profile simply hold both buttons for a couple of 
seconds or simply just leave the charger alone for 30 
seconds  and  it  will  change.  The  chosen  profile  LED 
shall  then  flash.  The  unit  shall  then  restart  and  go 
through the starting cycle again. 

Note

 - if you can only see LEDs on the right column the 

chances are you are in an error mode. This could be 
down  to:  Very  low  output  voltages  (<5V),  no  output 
connection,  reverse  polarity  or  the  device  is  not 
detecting  a  valid  operational  mode  as  the  connector 
wire  is  either  not  connected  or  the  connection 
configuration is wrong. Please refer to previous page. 

Left and right meter readings.

During normal operation

Out of range voltage values

If  voltage  exceeds  the  meter’s  range  the  upper  right 
LED shall flash. If the voltage falls short of the meter’s 
range  the  lower  LED  shall  flash.  If  two  neighbouring 
LEDs, on the voltmeter, are on simultaneously then the 
real  voltage  is  between  these  two  parameters. 
Example, if LEDs at 14.6V and 14.2V were on then the 
approximate voltage shall be ~14.4V.

Low or high output voltages

If the output voltage is below 1V (2V at 24V) or reverse 
polarity  then  the  low  output  voltage  LED  will  flash 
(number 23). Similarly, if the output voltage is above 
15.5V (31.0V at 24V) the high voltage LED shall flash 
(number  16).  To  resurrect  these  problems,  bring  the 
voltage  above  1V  on  the  output  and  below  15.5V, 
correct the polarity and then restart the device. 

Return  to  factory  default: 

This  shall  irreversibly 

erase all previously entered settings

. Press and hold 

both  buttons  for  30    and  let  go.  The  LED 
columns  shall  alternatively  flash.  To  confirm  factory 
default press BOTH buttons again for 2 seconds. Once 
confirmed,  3  green  LEDs  on  both  columns  shall  flash. 
Then, LEDs on the front panel shall light up in a clockwise 
pattern.  The  unit  should  then  reboot  with  the  default 
settings. To reject factory default settings, simply let the 
LED columns continue alternatively flashing. 

To view charger’s status:

Simply hold the SELECT button for 1 second and the right 
LED should flash indicating the status of the charger. This 
shall  flash  for  8  seconds.  To  return  quickly,  press  the 
SETUP/ENTER button once.

After unit has gone through its startup sequence the 
LEDs displayed should be the input voltage on the left 
column  and  the  output  voltage  on  the  right  column. 
Also, the top left LED (number 12) should be on solid 
which is the fast charge (bulk) LED. 

15.4 V
15.0 V
14.6 V
14.2 V
13.8 V
13.4 V
13.0 V
12.6 V
12.2 V

   Input voltage

    

   (x2 for 24V)

     Output voltage

              (x2 for 24V)

Bulk / Boost         Absorb             Cond.     Float (s) / Standby (fl)

IUOU

Battery charge
          progress

Charge state ->

Remember

 it is the voltages which are more important 

than our battery types. After installation test the voltage 
from the unit is the desired voltage. 

Ensure you remove 

at least 1 wire from the battery temperature sensor as 
the product voltage may be higher ( if in cold climate ) 
or lower ( if in warm climate ) than the preconceived 
voltage.

 

The  voltage  requirements  of  the  battery 

company will override our recommendations as it is them 
who are supporting the battery warranty.

Changing charging profile during operation.

While the unit is running, simply hold down the SETUP 
and SELECT buttons for 10-20 seconds and let go. The 
LEDs  on  the  left  column  shall  light  up.  The  procedure 
hereafter is the same as above. 

*Lithium  profile  has  reverse  polarity  protection 
disabled. **All voltages shall be 0.1V higher for the 
first 3 minutes of the chargers operation.

           Output V

oltage

15.4V
15.0V
14.6V
14.2V
13.8V
13.4V
13.0V
12.6V
12.2V

16
14
12
10

8
6
4
2
0

840
720
600
480
360
240
120

30

0

High Volt in (fl) / out (S)
High temp trip (fl)

No Fault (S) / P.Pack (fl)

Regen timer off (S) / on (fl)

Batt. Sense on (S)

Volt drop sense (fl)
1/2 power (S) / night (fl)  

Low Volt in (fl) / out (S)

                     
                     Bulk / Abs.    Cond.   Float     Min | Abs. | Max   

Volts
14.00
14.10
14.40
14.40
14.60
14.80
15.10
15.50
14.40
      Custom Charging Profile

Volts
13.70
13.40
13.60
13.80
13.70
13.30
13.60
--------
13.80

Mins

60
60

120
720

60
60
60

240

30

Mins

600
480
480

1440

480
480
360
240

30

Volts
13.85
13.75
14.15
14.00
14.10
14.00
14.30
--------
13.80

Options
1) Gel I
2) AGM I
3) Sealed
4) Gel II
5) AGM II
6) Open
7) Calcium
8) De-sulphation
9) LiFePO

4

10) Custom

 First Time Use (when wiring up)

If 

battery 

temperature 

sensor 

is 
connected 

then 

all 
voltages 

are 

based 

on 

20 

Deg 

C. 
If 

sensor 

senses less than 20DegC = increased voltage. 

Higher 

than 

20DegC 


decrease 

voltage. 

The 

further 

from 

20DegC 

in 
either 

direction 

leads 

to 

p

ro

p

o

rt

io

n

a

in

c

re

a

s

e

 

o

d

e

c

re

a

s

e

 

in

 

th

voltage.  

 (x2 

for 
24V 

| x3 
for 
36V 

| x4 
for 
48V)

High bat temp (fl) SVEM (S)

9

Содержание BB1230

Страница 1: ...e Float In Unit Out Rem Batt V 12 2 Temp Menu Change Volts Select Audible alarm on off hold 3 sec On Off hold 3 sec Fault Absorption Cond Optional Remote Instructions inside technology 4 DU L R A A T...

Страница 2: ...ustomise Operational Voltages Detailed Installation guide Page 8 Remote Control Operations Page 13 Operational m odes 1 2 3 Comprehensive breakdow n of remote functions Installation diagram Fault Find...

Страница 3: ...rrent limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARNING Nev...

Страница 4: ...tage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7 6 5 4 3 12 14 15 16 17 18 23 24 19 21 17 High temp trip if flashing then high unit temperature trip 18 No...

Страница 5: ...required Models BB1260 BB122470 BB123670 BB124870 BB242435 BB241235 Models BB1230 Front Panel II 8 2 3 4 7 10 11 12 13 9 5 14 5 3 4 BB122470 BB123670 BB124870 BB1260 BB242435 BB241235 4 60 73 00 4 60...

Страница 6: ...signal the BBC shall start charging again Use BMS 2 if your BMS trips to a ve voltage 2V 17V then use BMS 2 This shall result in the BBC turning off when this voltage is received Once the BMS removes...

Страница 7: ...2 seconds to confirm 2 x 3 sets of green LEDs shall flash to confirm Press Length s Action 0 1 Change to status fault display back to Voltage display mode 5 10 Toggles between 1 2 and 1 1 full power...

Страница 8: ...24V then the unit will simply start charging If the voltage drops below 13 0V the unit shall turn off With a caveat read on However if the input voltage has exceeded 13 2V 2x for 24V for 5 seconds the...

Страница 9: ...old both buttons for 30 seconds and let go The LED columns shall alternatively flash To confirm factory default press BOTH buttons again for 2 seconds Once confirmed 3 green LEDs on both columns shall...

Страница 10: ...auto regen timer starts to count If the voltage does not rise above 13 2V the timer will not reset and the unit will switch off however as soon as the voltage rises above 13 2V the auto regen timer w...

Страница 11: ...red custom values make a note Boost bulk absorption V ________ Conditioning V ________ Float V ________ AbsorptionTime Factor 0 18 ________ Absorption Minimum 0 960 minutes ________ Absorption Maximum...

Страница 12: ...ck mode constant voltage full current accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of...

Страница 13: ...e display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a note of th...

Страница 14: ...ltage is 0 13V starter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no...

Страница 15: ...does not apply for shipping organised by yourself Please do not throw out any shipping or packaging materials All returns for any reason will require a proof of purchase with the purchase date The pr...

Отзывы: