Sterling Power Products
Copyright
Opportunity to adjust minimum absorption time
factor
Red High Temp LED
will come on constant.
Yellow
Absorption LED
will flash and
will flash
blue Float
(section 2 and 4 on graph). This time, adjust the time
by using the Select and Setup buttons to go up and
down the right LED column (
refer to the brown scale 0-
960
) to select the correct time. Once content, wait 30
seconds, or press both buttons to confirm. The unit
shall then proceed to maximum absorption time factor
(next below).
During this particular setup procedure we have made
the voltage setup LED bar more sensitive so that the
adjustment can be made in 0.1V increments. For
example, for 13.1V the 13V LED is on and the 13.4V
LED is flashing. The same idea for 12.9V. The 13V
LED is on and the 12.6V LED is flashing.
Remember
that you are adjusting the
whilst
Cutoff voltage
simultaneous adjusting the
voltage
,
Charging
Lower voltage trip and the Low voltage trip
.
13.4V
13.4V LED ON
13.3V
13.4V LED ON + 13.0V LED FLASHING
13.2V
13.4V LED ON + 13.0V LED ON
13.1V
13.4V LED FL 13.0V LED ON
13.0V
13.0V LED ON
12.1V
12.2V LED FLASHING
12.0V
12.2V LED FAST FLASHING
To enter the menu press (SETUP/ENTER) &
SELECT for more than 20 seconds.
BOOST
CONDITIONING
,
,
and
ABSORPTION
FLOAT
LEDs will flash to indicate
Cutoff voltage
Setting Menu. At the same time the actual
Cutoff
voltage
will be displayed in the left LED voltage bar
according to the description above. To decrease
voltage press SETUP/ENTER and to increase
voltage press SELECT button.
The
range you can choose is
Cutoff voltage
between 12.0V-14.6V.
Charging voltage is always 0.2V higher.
Lower voltage trip is always 1.1V lower.
Low voltage trip (Mode 3) is always 3.0V lower.
If you do not touch any buttons for 30 seconds the
default voltage of 13.0V shall be restored and saved.
To confirm your custom voltage you must press
both buttons (SETUP/ENTER) and (SELECT)
simultanously for 2 seconds.
The chosen voltage will be saved and the unit will
restart. If you feel unsure do not touch any buttons.
The default value will be restored automatically.
10
If voltage drops
due to heavy
load in excess
off unit current
ability to support
Charging profile Information displayed on top 4 LEDs on main unit
Fast charge
constant current
mode
Stage 1
High absorption
charge rate constant
voltage mode
Stage 2
Lower conditioning
charge rate constant
voltage mode
Stage 3
Float / Power pack
mode, constant
voltage, full current
accessibility
Stage 4
Backlash voltage. If
charger power exceeded
and battery discharge
unit resets to stage 1
Stage 5
Time
(Depending on battery size, type, state of charge and charger battery ratio - Digitally processed)
v
o
l
t
s
Flash
Charging voltage
13.2V
13.0V
Cutoff voltage
Lower voltage trip
12.0V
Volt. trip w/ ign (Mode 3)
10.0V
Adjustment of operational voltages.
The 4 main control voltages below are inextricably linked.
The voltages can only be adjusted as a block (not
individually). For example, if you wish to reduce the
Cutoff
voltage
by 0.2V then all other voltages in the block shall
reduce by 0.2V.
Opportunity to adjust maximum absorption
time factor
Red High Temp LED
will come on constant.
Green
Conditioning LED
will flash and
will flash
blue Float
(section 3 and 4 on graph). This time, adjust the time
by using the Select and Setup buttons to go up and
down the right LED column (
refer to the brown scale
0-960
) to select the correct time. Once content, wait
30 seconds, or press both buttons to confirm.
A
from the middle of each row will flash
green LED
for around 8 seconds to confirm the setup is
completed. The unit will then restart.
regen braking timer
All 4 voltages are always
linked. This block can be
adjusted by changing the
Cutoff voltage
value up and
down. This subsequently
changes the other three
voltages by the same value.
Charging voltage (default 13.2V) (always 0.2V above
Cutoff voltage)
:
At this voltage the charger starts
charging. After 5 seconds above 13.2V the regen braking
timer is set. If the input voltage drops to 11.9V - 13.0V this
timer begins. Timer reset when input voltage is 13.2V+.
Cutoff voltage (default 13.0V):
This voltage is only
relevant after the
charging voltage
has been met and the
charger is charging. When the input voltage drops below
this cutoff voltage the charger stops charging and shall
eventually go to sleep. If the input voltage remains
between 13.0V-13.2V the charger shall continue charging.
The
Cutoff voltage is the parameter that the user
changes.
Cutoff voltage
As noted, by adjusting the
you
change the other three voltages mentioned by the same
amount.
Lower voltage trip (default 11.9V) (always 1.1V below
Cutoff voltage)
:
When the input voltage drops below the
Lower voltage trip
the charger turns off. The 11.9V
threshold is only relevant if the
is
regen braking timer
activated. If not, then the low voltage trip is 13.0V. If in
mode 3, the low voltage trip is 10.0V.
Low voltage trip (default 10.0V) (Mode 3) (always 3.0V
below
:
Only when in operation mode 3
Cutoff voltage)
does the Pro Batt Ultra work down as low at this voltage.
Input voltage
12