Opportunity  to  adjust  minimum  absorption  time 
factor

 

Red  High Temp  LED

  will  come  on  constant. 

Yellow 

Absorption  LED

  will  flash  and 

  will  flash 

blue  Float

(section 2 and 4 on graph). This time, adjust the time 
by using the Select and Setup buttons to go up and 
down the right LED column (

refer to the brown scale 0-

960

) to select the correct time. Once content, wait 30 

seconds, or press both buttons to confirm. The unit 
shall then proceed to maximum absorption time factor 
(next below).

During this particular setup procedure we have made 
the voltage setup LED bar more sensitive so that the 
adjustment  can  be  made  in  0.1V  increments.  For 
example, for 13.1V the 13V LED is on and the 13.4V 
LED is flashing. The same idea for 12.9V. The 13V 
LED is on and the 12.6V LED is flashing. 

Remember 

that  you  are  adjusting  the

whilst 

 

Cutoff  voltage 

simultaneous  adjusting  the 

  voltage

Charging

Lower voltage trip and the Low voltage trip

13.4V 

13.4V LED ON

13.3V 

13.4V LED ON + 13.0V LED FLASHING

13.2V 

13.4V LED ON + 13.0V LED ON

13.1V 

13.4V LED FL 13.0V LED ON

13.0V  

13.0V LED ON

12.1V 

12.2V LED FLASHING

12.0V 

12.2V LED FAST FLASHING

To  enter  the  menu  press  (SETUP/ENTER)  & 
SELECT for more than 20 seconds. 

BOOST

CONDITIONING

  and 

ABSORPTION

FLOAT 

LEDs  will  flash  to  indicate 

 

Cutoff  voltage

Setting  Menu.  At  the  same  time  the  actual 

Cutoff 

voltage

 will be displayed in the left LED voltage bar 

according  to  the  description  above.  To  decrease 
voltage  press  SETUP/ENTER  and  to  increase 
voltage press SELECT button.
The 

  range  you  can  choose  is 

Cutoff  voltage

between 12.0V-14.6V. 

Charging voltage is always 0.2V higher.
Lower voltage trip is always 1.1V lower.
Low voltage trip (Mode 3) is always 3.0V lower. 

If you do not touch any buttons for 30 seconds the 
default voltage of 13.0V shall be restored and saved.

To confirm your custom voltage you must press 
both  buttons  (SETUP/ENTER)  and  (SELECT) 
simultanously for 2 seconds.

The chosen voltage will be saved and the unit will 
restart. If you feel unsure do not touch any buttons. 
The default value will be restored automatically. 
  

10

If voltage drops

due to heavy 

load  in excess

 off unit  current

 ability to support

Charging profile Information displayed on top 4 LEDs on main unit 

Fast charge

 constant current

mode 

Stage 1

High absorption 

charge rate constant 

voltage mode 

Stage 2

Lower conditioning 

charge rate constant 

voltage mode 

Stage 3

Float / Power pack

mode, constant

voltage, full current

accessibility

Stage 4 

Backlash voltage. If

 charger power exceeded 

 and battery discharge 

 unit resets to stage 1

Stage 5 

Time 

(Depending on battery size, type, state of charge and charger battery ratio - Digitally processed)

v
o
l
t
s

Flash

Charging voltage   

                

13.2V

  

 

                  13.0V

Cutoff voltage      

Lower voltage trip 

                

12.0V

Volt. trip w/ ign (Mode 3)

      

10.0V

Adjustment of operational voltages.

The 4 main control voltages below are inextricably linked. 
The  voltages  can  only  be  adjusted  as  a  block  (not 
individually). For example, if you wish to reduce the 

Cutoff 

voltage

 by 0.2V then all other voltages in the block shall 

reduce by 0.2V. 

Opportunity  to  adjust  maximum  absorption 
time factor 

Red High Temp LED

 will come on constant. 

Green 

Conditioning LED

 will flash and 

 will flash 

blue Float

(section 3 and 4 on graph). This time, adjust the time 
by using the Select and Setup buttons to go up and 
down the right LED column (

refer to the brown scale 

0-960

) to select the correct time. Once content, wait 

30 seconds, or press both buttons to confirm.

 from the middle of each row will flash 

green LED

for  around  8  seconds  to  confirm  the  setup  is 
completed. The unit will then restart. 

regen braking timer

All  4  voltages  are  always 
linked.  This  block  can  be 
adjusted  by  changing  the 

Cutoff voltage

 value up and 

down.  This  subsequently 
changes  the  other  three 
voltages by the same value. 

Charging voltage (default 13.2V) (always 0.2V above 

Cutoff  voltage)

:

  At  this  voltage  the  charger  starts 

charging. After 5 seconds above 13.2V the regen braking 
timer is set. If the input voltage drops to 11.9V - 13.0V this 
timer begins. Timer reset when input voltage is 13.2V+.

Cutoff  voltage  (default  13.0V):

  This  voltage  is  only 

relevant after the 

charging voltage

 has been met and the 

charger is charging. When the input voltage drops below 
this  cutoff  voltage  the  charger  stops  charging  and  shall 
eventually  go  to  sleep.  If  the  input  voltage  remains 
between 13.0V-13.2V the charger shall continue charging.  
The 

Cutoff  voltage  is  the  parameter  that  the  user 

changes. 

Cutoff voltage

As noted, by adjusting the 

 you 

change the other three voltages mentioned by the same 
amount.  

Lower voltage trip (default 11.9V) (always 1.1V below 

Cutoff voltage)

When the input voltage drops below the 

Lower  voltage  trip

  the  charger  turns  off.  The  11.9V 

threshold  is  only  relevant  if  the 

  is 

regen  braking  timer

activated.  If  not,  then  the  low  voltage  trip  is  13.0V.  If  in 
mode 3, the low voltage trip is 10.0V.

Low voltage trip (default 10.0V) (Mode 3) (always 3.0V 
below 

:

 Only when in operation mode 3 

Cutoff voltage)

does the Pro Batt Ultra work down as low at this voltage.     

Input voltage

12

Содержание BB1230

Страница 1: ...e Float In Unit Out Rem Batt V 12 2 Temp Menu Change Volts Select Audible alarm on off hold 3 sec On Off hold 3 sec Fault Absorption Cond Optional Remote Instructions inside technology 4 DU L R A A T...

Страница 2: ...ustomise Operational Voltages Detailed Installation guide Page 8 Remote Control Operations Page 13 Operational m odes 1 2 3 Comprehensive breakdow n of remote functions Installation diagram Fault Find...

Страница 3: ...rrent limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARNING Nev...

Страница 4: ...tage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7 6 5 4 3 12 14 15 16 17 18 23 24 19 21 17 High temp trip if flashing then high unit temperature trip 18 No...

Страница 5: ...required Models BB1260 BB122470 BB123670 BB124870 BB242435 BB241235 Models BB1230 Front Panel II 8 2 3 4 7 10 11 12 13 9 5 14 5 3 4 BB122470 BB123670 BB124870 BB1260 BB242435 BB241235 4 60 73 00 4 60...

Страница 6: ...signal the BBC shall start charging again Use BMS 2 if your BMS trips to a ve voltage 2V 17V then use BMS 2 This shall result in the BBC turning off when this voltage is received Once the BMS removes...

Страница 7: ...2 seconds to confirm 2 x 3 sets of green LEDs shall flash to confirm Press Length s Action 0 1 Change to status fault display back to Voltage display mode 5 10 Toggles between 1 2 and 1 1 full power...

Страница 8: ...24V then the unit will simply start charging If the voltage drops below 13 0V the unit shall turn off With a caveat read on However if the input voltage has exceeded 13 2V 2x for 24V for 5 seconds the...

Страница 9: ...old both buttons for 30 seconds and let go The LED columns shall alternatively flash To confirm factory default press BOTH buttons again for 2 seconds Once confirmed 3 green LEDs on both columns shall...

Страница 10: ...auto regen timer starts to count If the voltage does not rise above 13 2V the timer will not reset and the unit will switch off however as soon as the voltage rises above 13 2V the auto regen timer w...

Страница 11: ...red custom values make a note Boost bulk absorption V ________ Conditioning V ________ Float V ________ AbsorptionTime Factor 0 18 ________ Absorption Minimum 0 960 minutes ________ Absorption Maximum...

Страница 12: ...ck mode constant voltage full current accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of...

Страница 13: ...e display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a note of th...

Страница 14: ...ltage is 0 13V starter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no...

Страница 15: ...does not apply for shipping organised by yourself Please do not throw out any shipping or packaging materials All returns for any reason will require a proof of purchase with the purchase date The pr...

Отзывы: