Sterling Power Products BB122470 Скачать руководство пользователя страница 5

5

SELECT

Specification:
12V-12V 60A
Current limiting
Thermostatic control fan
Auto or ignition feed 

SETUP

ENTER

Background

light

on

unit 

active

www.sterling-power-usa.com

www.sterling-power.com

Designed and 

developed 
in England 

Made in Taiwan

technology

4

L : DUR

A

A

IT

B

L

IG

E

D

 

 

:

:

 

 

D

C

E

I

M

S

A

G I

N

N

Y

D

ProDigital 

To remove lid gently press the sides in no more 

than about 4 mm and slide out the lid.

1

2

3

4

5

7

10

11

8

9

14

+
+
+
+

+
+

Remote control

Battery 

temperature 

sensor

Rem V sense
see side
info
label

SETUP
ENTER

SELECT

Reverse 

polarity

tell

Enter/Select

buttons under cover

f
u
s
e

Reverse 

polarity

tell

f
u
s
e

f u e s 

regen

braking

Bat

in +

Bat

out +

Neg

-

12

13

6

The mm2 figures have been rounded up to suit European cable availability.  

20A    

   

Distance  

   3m (10 ft)       5m (15ft)      7m (22ft)     8m (25ft)      9m (30ft) 

mm2 / 

 

 2.5 / 

          2.5 / 

         4.0 / 

       4.0 / 

         6.0 / 

AWG

14

14

12

12

10

30A   

    

Distance  

   3m (10 ft)       5m (15ft)      7m (22ft)     8m (25ft)      9m (30ft) 

mm2 / 

 

 6.0 / 

         6.0 / 

         6.0 / 

        6.0 /

      10.0 /

AWG

10 

10

10

 10 

 8

40A 

      

Distance  

   3m (10 ft)       5m (15ft)      7m (22ft)     8m (25ft)      9m (30ft) 

mm2 / 

 10.0 /           10.0 /           10.0 /          10.0 /        

 

16.0 /

AWG

 8

8

8

 8

 6

50A  

     

Distance  

   3m (10 ft)       5m (15ft)      7m (22ft)     8m (25ft)      9m (30ft) 

mm2 / 

  16.0 /            16.0 /         16.0 /          16.0 /         16.0 / 

AWG

6

6

 6

6

60A 

      

Distance  

   3m (10 ft)       5m (15ft)      7m (22ft)     8m (25ft)      9m (30ft) 

mm2 / 

  16.0 /            16.0 /

      16.0 /          16.0 /         25.0 / 

AWG

 6 

6

 6

4

Nominal 

Fuse size for 

input & output

30A

40A

50A

70A

 

80A

Recommended cable size for current required 

Under the lid

1) DC output fuse
2) Negative fuse (position, model dependent)
3) DC output to aux battery
4) Common negative
5) DC input from start battery (green connector or  
brass nut/bolt - model dependent). 
6) DC input fuse
7) Remote control socket
8) Low Voltage (regenerative braking)
9) Ignition feed connector
10) Auto regen. mode (default w/ ign feed)

11) Remote battery sense wire to compensate for 
voltage drop in cable (optional, does not need to 
be used). 
12) Battery temperature sensor, optional fit, if not 
used  product  will  work  on  default  of  20  deg  C 
setting. 
13) Other wire associated with the temp sensor as 
per 12.
14) Reverse polarity tell tale diodes. If damaged, 
will show if unit has been reverse polarity and not 
under  warranty.  Position  of  diodes  are  model 
dependent.

Models:
BB1260  / BB122470 / BB123670 / BB124870 / 
BB242435 / BB241235   
   

S

TERLI   G

P

OWER

Models:
BB1230
BB122440

 Front Panel II

+

+

+

+
+

+
+

+
+

8

1

2

3

4

6

7

10

11

12

13

9

5

14

+
+

+
+

+
+

+ +

5

3

4

1

6

BB122470
BB123670
BB124870

BB1260
BB242435
BB241235

einfache

Entfernung 

1m

2m

3m

4m

5m

Empf.

Sicherung

30A Gerät

6mm²

10mm²

16mm²

16mm²

25mm²

50A

60A Gerät

16mm²

25mm²

25mm²

35mm²

35mm²

100A

Stationary vehicle engage mode.

Unit on at 13.1V input.
When input below 12.9V, a 20 second 
timer starts - if still below 12.9V after the 20 
seconds the unit goes to sleep. Requires 
13.1V to come on again. 

Содержание BB122470

Страница 1: ...than 13 6V input in order to activate Please read about the Stationary vehicle engagement mode later in the manual Code BB1230 12V 12V 30A input BB122440 12V 24V 40A input battery temp sensor USERS M...

Страница 2: ...m Force operation w ithout output voltage Maintenance and Repair Force Float mode Safety and Precautions Force Unit on off Display annotations Page 4 5 Force Unit to half pow er mode Front Label displ...

Страница 3: ...r DC current limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARN...

Страница 4: ...the top or bottom red LED is on then the voltage is outside the parameters off the voltmeter 16 High voltage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7...

Страница 5: ...3m 10 ft 5m 15ft 7m 22ft 8m 25ft 9m 30ft mm2 16 0 16 0 16 0 16 0 16 0 AWG 6 6 6 6 6 60A Distance 3m 10 ft 5m 15ft 7m 22ft 8m 25ft 9m 30ft mm2 16 0 16 0 16 0 16 0 25 0 AWG 6 6 6 6 4 Nominal Fuse size f...

Страница 6: ...nal Modes 1 2 3 1 2 3 Unit will work on default setting if temperature sensor not fitted Quick Guide to the buttons on the front panel Refer to Pages 8 11 for in depth procedure Ignition Feed w o time...

Страница 7: ...want the unit to turn off the second you turn the ignition off yet have the ability to have input voltage flexibility WARNING with this setting flat batteries as the charger works down to 11 5V How to...

Страница 8: ...LED will flash number 23 Similarly if the output voltage is above 15 5V 31 0V at 24V the high voltage LED shall flash number 16 To resurrect these problems bring the voltage above 6V on the output and...

Страница 9: ...en the 1 2 power and night LED flashes 4 times This function will help reduce fan noise in the short term in the evenings for example The unit will revert back to full power after 8 hours automaticall...

Страница 10: ...___ Absorption Minimum 0 960 minutes ________ Absorption Maximum 0 960 minutes ________ STERLI G POWER Operation Press and hold both buttons for 20 seconds All Left LEDs shall flash Press the setup bu...

Страница 11: ...rent accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of charge and charger battery ratio...

Страница 12: ...then the display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a no...

Страница 13: ...arter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no loads chargers on...

Отзывы: