Press and hold both buttons for 12-14 seconds.

All Left LEDS flash

Press setup to move LED down to custom. Hold both buttons for 2 seconds to confirm. 

Opportunity to adjust Fast Charge voltage

.  

Red 

Custom LED will flash for 3 seconds to confirm. Custom LED will come on constant, 

green Fast charge LED will flash (section 1 on graph).  

Adjust Fast Charge by increasing the 

 on label. Select button will increase 

green voltage

voltage whilst setup will lower. 

Wait 30 seconds or press both buttons to confirm this.

Opportunity to adjust conditioning charge voltage  

Red

 Custom LED will come on constant and Green Conditioning LED will flash (section 3 

on graph).

Adjust Conditioning Charge by increasing the 

 on label. Select button will 

green voltage

increase voltage whilst setup will lower. 

Wait 30 seconds or press both buttons to confirm this.

Red

 Custom LED will come on constant and 

 Float LED will flash (section 4 on 

Blue

graph)

Adjust Float by increasing the 

 on label. Select button will increase voltage 

green voltage

whilst setup will lower. 

Wait 30 seconds or press both buttons to confirm this.

Opportunity to adjust Time factor    

Red

 High Temp LED will come on constant, Green Fast Charge LED will flash and 

 

blue

Float will flash (section 1 and 4 on graph).

Adjust Time Factor by increasing or decreasing the 

 on label. Select 

brown scale (0-960)

button will increase time whilst setup will lower. 

Wait 30 seconds or press both buttons to confirm this.

Opportunity to adjust Minimum absorption time factor  

Red

 High Temp LED will come on constant, 

Absorption LED will flash and 

 

Yellow 

blue

Float will flash (section 2 and 4 on graph).

Adjust Time Factor by increasing or decreasing the 

 on label. Select 

brown scale (0-960)

button will increase time whilst setup will lower. 

Wait 30 seconds or press both buttons to confirm this.

Opportunity to adjust Maximum absorption time factor    

Red

 High Temp LED will come on constant, Green Conditioning LED will flash and 

 

blue

Float will flash (section 3 and 4 on graph).

Adjust Time Factor by increasing or decreasing the 

 on label. Select 

brown scale (0-960)

button will increase time whilst setup will lower. 

Wait 30 seconds or press both buttons to confirm this.

A green LED from the middle of each row will flash for around 8 seconds to confirm the 

setup is completed. The unit will then restart. 

  

A

B

D

E

F

CUSTOM BATTERY TYPE SETTING

 

(for expert 

use only - not required for general operation)

Before  proceeding  with  this,  please  read  and 
understand all instructions as it is quite complex and 
could take more than one attempt. There are timed 
intervals  of  30  seconds  per  setting  so  it  is  very 
important to know exactly what you require before 
starting. If any errors are made simply wait a few 
minutes  and  you  can  start  the  cycle  again.  The 
settings offered for adjustment in sequence:

A)

 Boost / absorption voltage (high voltage charge).          

B)

  Conditioning  voltage  (medium  charge  rate   

normally between boost and float voltage).

C)

  Float  voltage  (no  longer  charging,  this  will 

provide voltage at a reduced level to maintain the 
batteries and provide power for any loads applied).  

D)

 Absorption time factor adjust. The length of time 

spent in absorption can be adjusted by a factor 0-16. 
This  may  be  beneficial  for  different  battery 
chemistries.  Gel,  for  example,  tends  to  absorb 
current at a low rate, thus, increasing the length of 
time  spent  in  absorption  may  be  beneficial  (set 
nearer 16). AGM, the reverse (set nearer 0). If in any 
doubt, ask your battery retailer or simply use one of 
our preset values. To calculate the absorption time 
from  the  time  factor  simply  multiply  the  factor 
number (0-16) by 60 and this give you the time in 
minutes. E.g. set to 0 and the absorption time shall 
be 0 x 60 = 0 minutes. Therefore, the unit shall go 
direct  from  bulk  to  conditioning  (no  absorption). 
Alternatively, set the factor to 10. This equates to 10 
x 60 = 600 minutes etc... The maximum time the unit 
can stay in absorption is 24 hours 1440 minutes.  

E) 

Minimum and maximum absorption times.

Here you can set the maximum and minimum time 
the unit stays in absorption. For example, you may 
have AGM that may need a maximum of one hour, 
or  GEL  which  could  require  a  minimum  of  720 
minutes (12 hours). 

We recommend that you write down your required 
voltages and times in the space below. This is so 
you know what to programme during setup.

Desired custom values - make a note.

Boost / bulk / absorption (V)                    ________
Conditioning (V) 

 

              ________ 

Float (V)                                                 ________
Absorption Time Factor (0-18)                ________
Absorption Minimum (0-960 minutes)     ________
Absorption Maximum (0-960 minutes)    ________
 

 

S

TERLI   G

P

OWER

Operation

Press and hold both buttons for 20+ seconds.

All Left LEDs shall flash

Press the setup button to move LED down to custom. 
Hold both buttons for 2 seconds to confirm.
 

Opportunity  to  adjust  Fast  Charge    /  Bulk  / 
Absorption voltage

.

 

Red Custom LED

 will flash for 3 seconds to confirm. 

Red Custom LED

 will come on constant, 

Green Fast 

Charge  LED

  will  flash  (section  1  on  graph). Adjust 

Fast Charge voltage by using the Select and Setup 
buttons to go up and down the right LED column to 
select the correct Fast Charge voltage. Once content, 
wait 30 seconds, or press both buttons to confirm. The 
unit shall then proceed to Conditioning charge voltage 
(next below).

Opportunity  to  adjust  Conditioning  charge 
voltage 

Red Custom LED

 will come on constant and 

Green 

Conditioning  LED

  will  flash  (section  3  on  graph). 

Likewise, adjust the conditioning voltage by using the 
Select and Setup buttons to go up and down the right 
LED  column  to  select  the  correct  Conditioning 
voltage. Once content, wait 30 seconds, or press both 
buttons to confirm. The unit shall then proceed to float 
voltage set (next below).

Opportunity to adjust float charge voltage

 

Red  Custom  LED

  will  come  on  constant  and

  Blue 

Float  LED

  will  flash  (section  3  on  graph).  Likewise, 

adjust the float voltage by using the Select and Setup 
buttons to go up and down the right LED column to 
select the correct Float voltage. Once content, wait 30 
seconds, or press both buttons to confirm. The unit 
shall then proceed to float voltage set (next below).

Opportunity to adjust absorption time factor 

 

Red  High  Temp  LED

  will  come  on  constant. 

Green 

Fast Charge LED

 will flash and 

 will 

Blue Float LED

flash (section 1 and 4 on graph). This time, adjust the 
time by using the Select and Setup buttons to go up 
and down the right LED column (

refer to the 

 

blue scale

scale 0-18

) to select the correct time. Once content, 

wait 30 seconds, or press both buttons to confirm. The 
unit shall then proceed to minimum absorption time 
factor (next below).

Why use Absorption Time Factor (ATF)? 

ATF  is  simply  a  number  (0-18)  that  can  be  used  to 
multiply  by  the  length  of  time  the  charger  takes  to 
reach the bulk/boost voltage from start. For example, 

if the bulk voltage is reached in 10 minutes with the 
ATF  at  4,  then  10mins  x  (ATF  4)  =  40  mins  of 
absorption. 

  

10

 Custom Settings

Stationary vehicle engage mode.

Unit on at 13.1V input.
When input below 12.9V, a 20 second 
timer starts - if still below 12.9V after the 20 
seconds the unit goes to sleep. Requires 
13.1V to come on again. 

Содержание BB122470

Страница 1: ...than 13 6V input in order to activate Please read about the Stationary vehicle engagement mode later in the manual Code BB1230 12V 12V 30A input BB122440 12V 24V 40A input battery temp sensor USERS M...

Страница 2: ...m Force operation w ithout output voltage Maintenance and Repair Force Float mode Safety and Precautions Force Unit on off Display annotations Page 4 5 Force Unit to half pow er mode Front Label displ...

Страница 3: ...r DC current limiting With fuses protecting the DC cables In a well ventilated dry dust free and condensation free environment When instruction manual has been read through Safety Symbols Example WARN...

Страница 4: ...the top or bottom red LED is on then the voltage is outside the parameters off the voltmeter 16 High voltage if on solid it is high output voltage if flashing it is high input voltage 10 11 13 8 9 7...

Страница 5: ...3m 10 ft 5m 15ft 7m 22ft 8m 25ft 9m 30ft mm2 16 0 16 0 16 0 16 0 16 0 AWG 6 6 6 6 6 60A Distance 3m 10 ft 5m 15ft 7m 22ft 8m 25ft 9m 30ft mm2 16 0 16 0 16 0 16 0 25 0 AWG 6 6 6 6 4 Nominal Fuse size f...

Страница 6: ...nal Modes 1 2 3 1 2 3 Unit will work on default setting if temperature sensor not fitted Quick Guide to the buttons on the front panel Refer to Pages 8 11 for in depth procedure Ignition Feed w o time...

Страница 7: ...want the unit to turn off the second you turn the ignition off yet have the ability to have input voltage flexibility WARNING with this setting flat batteries as the charger works down to 11 5V How to...

Страница 8: ...LED will flash number 23 Similarly if the output voltage is above 15 5V 31 0V at 24V the high voltage LED shall flash number 16 To resurrect these problems bring the voltage above 6V on the output and...

Страница 9: ...en the 1 2 power and night LED flashes 4 times This function will help reduce fan noise in the short term in the evenings for example The unit will revert back to full power after 8 hours automaticall...

Страница 10: ...___ Absorption Minimum 0 960 minutes ________ Absorption Maximum 0 960 minutes ________ STERLI G POWER Operation Press and hold both buttons for 20 seconds All Left LEDs shall flash Press the setup bu...

Страница 11: ...rent accessibility Stage 4 Backlash voltage If charger power exceeded and battery discharge unit resets to stage 1 Stage 5 Time Depending on battery size type state of charge and charger battery ratio...

Страница 12: ...then the display shall read loc on number you have stored To remove loc return to loc and re enter the number Press select button and the display should read loc off green back light Please make a no...

Страница 13: ...arter battery voltage then alternator may have failed Or requires increase rpm of engine possible belt slip Is your output voltage slightly higher or lower than expected even with no loads chargers on...

Отзывы: