Page 10
For HELP, call 800.749.8003
Parts with extra low voltage not exceeding 12v must be inaccessible to a person
in the hot tub. Earthed appliances must be permanently connected to fixed
wiring. Parts incorporating electrical components, except remote control devices,
must be located or fixed so that they cannot fall into the hot tub.
Means for disconnection must be used in fixed wiring in accordance with wiring
rules.
Important –
To allow the 240V GFCI to function properly, connect the white
Neutral wire from the hot tub to the Neutral terminal on the GFCI breaker, not the
Neutral bus in the GFCI breaker box. An improperly connected Neutral causes
the GFCI breaker to trip.
Wiring Diagrams
GFCI
G
N
D
N
E
U
T
Correct
To
Spa
To
Main
Hot Tub GFCI Breaker Box Wiring
Incorrect
2 White wires
on Neutral Bus
3 White wires
on Neutral Bus
GFCI
G
N
D
N
E
U
T
To
Main
To
Spa
Figure 3 – 240V GFCI Wiring
Содержание Desire
Страница 34: ...Page 32 For HELP call 800 749 8003 ML700 Programming Summary Figure 24 8 button Programming Summary ...
Страница 38: ...Page 36 For HELP call 800 749 8003 Notes ...
Страница 55: ...Page 53 For HELP call 800 749 8003 Notes ...
Страница 61: ...Page 59 For HELP call 800 749 8003 Passion Callouts Passion Parts ...
Страница 63: ...Page 61 For HELP call 800 749 8003 Essence Callouts Essence Parts ...
Страница 65: ...Page 63 For HELP call 800 749 8003 Desire Callouts Desire Parts ...
Страница 67: ...Page 65 For HELP call 800 749 8003 Pure Callouts Pure Parts ...
Страница 69: ...Page 67 For HELP call 800 749 8003 Pristine Callouts Pristine Parts ...
Страница 72: ...6101 45th St N St Petersburg FL 33714 800 749 8003 www SterlingLeisure com ...