SLIDE MOUNT - (BAG B.3)

The Sterisil

®

 System G5 will come with the slides affixed in the 

correct direction for proper maintenance. Please consider the 

orientation of the slides and affixing the slide mount to the wall 

mounting plate before you start.

Affixing the Slide Mount to the Wall

• Mark the holes on the slide mounting plate.

• Screw the mounting plate to the wall and ensure it is level. 

Securing the G5 to the Slide Mount

• Take the system and line up the rails on the back of the waffle 

plate to the slides on the mounting plate. Slide the unit until 

you hear the rails snap into place.

• Verify it is level.

ARTICULATING MOUNT - (BAG B.2) 

Affixing the Articulating Mount to the Wall

• Use articulating mount hardware (included in package).

• Place the mount against the wall with the “up” arrow facing 

the ceiling. Ensure the mount is level and mark your holes.

• Pilot holes are either 3/8” or 9/64”.

• Affix the mount to the wall with the appropriate combination 

of hardware for your mounting surface. 

• Confirm it is level. 

Securing the G5 to the Articulating Mount

• The system will come with the waffle plate attached. Tack 

the X-plate to the back of the waffle plate. You may need to 

place the unit on the front face to accomplish this. Please 

be mindful of the touchscreen if you do so. Use the packing 

foam to avoid damage to the touchscreen.

• Mount the X-plate to the waffle plate using the bolts and 

washers. Make sure the “up” arrow is facing the top of the 

system.

• You will notice a notch in the upper middle portion of the 

X-plate. Tighten a screw nut to this notch. 

• Mount the system to the articulating mount by hanging the 

top screw nut affixed to the X-plate in the notch on the arm 

mount. 

• Fasten the entire assembly to the wall mount with the two 

remaining nuts. Be sure the unit is level and tighten with 1/2” 

wrench.

• Properly orient the unit and tighten the forward tilt nuts once 

system is completely level.

PERIPHERAL COMPONENTS

Peripheral components – No more than 50 feet from the system.

Depending on the customer’s specific configuration you may have optional components such as the Pre-filter 

Kit and Booster Pump plumbed between the municipal source and the red “SOURCE” port on the system.

G5 POWER ADAPTER

• Select location within 6 feet of the outlet. Ensure there is no tension on the cable.

• If you choose to mount the power adapter on the wall, use hardware straps provided.

WATER STORAGE TANKS - (BAG C)

Storage tank sizes may differ with customer specifications and needs. Note: tank sizes will vary depending on 

Stage 5 selection or pre-install requirements. As a default, the RO tank will be the larger of the two. Storage 

tanks must be mounted within 50 feet of the system to maintain optimal water pressure. Set storage tanks in 

desired locations. A common location is under a sterilization center sink.

• Wrap the threads with Teflon tape (included) on each bladder tank. Install the 3/8” valve and hand tighten it to 

the larger RO tank. Do not over tighten this valve.

• Repeat this process with the 1/4” valve for the Dental Water Tank.

• Ensure the pressure of the tanks is between 8–10 psi Schrader valved pressure gauge.

FAUCET(S) INSTALLATION

The bottle fill configuration includes a white Autoclave Faucet and a chrome Dental Water Faucet. Dental water 

is always plumbed to the chrome faucet. Typical mounting location is on a counter-top extended over a sink.

Direct feed systems only use the white Autoclave Faucet. Dental water is fed directly to the dental unit hand 

pieces.

COUNTER-TOP MOUNT

Faucet assembly instructions are located on the back of the faucet box.

• Do not use the compression fittings provided. Instead use the provided push-fit connect.

• Drill 5/8” hole at the desired location.

• Place the faucet through the hole and mount using the hardware (included).

• Wrap the thread with thread tape prior to install.

• Place the under-sink mounting washer, and install the nut (included in box) and hand tighten.

 

 

 

 

Washer

Lock Washer

Quick Connect 

Fitting

Plastic Gasket

Nut

Slide mount

Notch

Articulating mount

X-plate

Содержание System G5

Страница 1: ...INSTALLATION AND MAINTENANCE MANUAL GP9003 A ...

Страница 2: ...the user to see real time data from a network of on board sensors for convenient system health monitoring In the event of a maintenance alert users can access built in troubleshooting guides pertaining to their specific error for quick and easy resolution 835 S Highway 105 Suite D Palmer Lake CO 80133 Office 719 622 7200 Fax 866 299 2495 Sterisil offers optional add ons to the G5 to ensure proper ...

Страница 3: ...r go to the settings tab on the touchscreen Record the installation date on the warranty card Please ensure you send in the warranty card or register online The initial set up can take up to 3 5 hours depending on customer specifications Ensure the lengths of tubing provided will meet the needs of your specific configuration All tubing cuts should be made at a right angle to the tubing itself Be s...

Страница 4: ...of mounting the system Sterisil recommends anchoring the system into a wall stud The EZ toggle anchors should only be used when drilling into drywall STATIC MOUNT BAG B 1 Affixing the Static Plate to the Wall Identify the slotted holes on the plate These slots will be used to mount the plate to the wall The static plate is symmetrical so any side can be up Mock up your static mounting plate in the...

Страница 5: ...ERIPHERAL COMPONENTS Peripheral components No more than 50 feet from the system Depending on the customer s specific configuration you may have optional components such as the Pre filter Kit and Booster Pump plumbed between the municipal source and the red SOURCE port on the system G5 POWER ADAPTER Select location within 6 feet of the outlet Ensure there is no tension on the cable If you choose to...

Страница 6: ... D Tank Port Blue fitting Indicator Run 1 4 tubing from the blue DENTAL port on the system to the 1 4 Tank Ball Valve on the smaller dental water storage tank Autoclave Port Green fitting indicator OPTIONAL ADD ON Sterisil Wand see page 14 Run 1 4 tubing from the green AUTOCLAVE port on the system to the white Autoclave Faucet Drain Port Black fitting indicator Bag D Run a 1 4 line from the black ...

Страница 7: ...DD ONS PRE FILTER KIT OPTIONAL COMPONENT Considerations Account for a minimum of 2 clearance at the bottom for future filter replacements Location of Pre filter and Inline Ball Valve diagram is on page 5 Turn off your source water Find a location where you can drive the screws for the bracket into the wall that will reach both your source water line and your Sterisil System G5 source line If you h...

Страница 8: ...for 60 seconds For change outs on Stages 1 4 close the RO tank and run the autoclave water For Stage 5 change outs close the Dental Storage Tank and run the dental water Stage 5 7 Open all tanks to finish 8 Cartridges can either be discarded in the trash or returned to Sterisil for recycling For more information on our recycling program visit sterisil com recycle Make a clean square cut on the sou...

Страница 9: ...ed Sterisil Cartidges by a click of a button Simply visit sterisil com green or call us directly to request a free shipping label While other companies dispose 100 of their used products to a landfill Sterisil is able to recycle 91 of our Straws and Cartridges In addition to recycling Sterisil contributes to a greener environment by being the only dental waterline company to offer a residual disin...