INSTALLATION

Visit 

sterisil.com/sterisil-system-g5 

to view the System installation video. 

719 622 7200

[email protected]

NEED HELP OR HAVE QUESTIONS?

Our technical support staff is available and 

ready to help. Please call, email, or visit us 

online for additional support.

sterisil.com

TABLE OF CONTENTS

Introduction

3

Before you Begin

4

Phase 1: Unpacking and Inventory

6

Phase 2: Mounting and Peripheral Components

7

Phase 3: Cartridges

10

Phase 4: Source Water and Tubing

10

Phase 5: Powering Up, Programming the Touchscreen and Filling the Tanks

11

Operational Test

12

Optional Add-ons

13

Maintenance Manual

15

Sterisil Limited Warranty

17

INTRODUCTION

The Sterisil

®

 System G5 takes the existing 6 stages of water treatment found in our G4 Systems and merges 

them with an on-board Class A ultraviolet disinfectant and integrated smart technology. The result is the most 

advanced dental water treatment system in the world. 

The G5 employs Sterisil’s potent silver based residual disinfectant delivering a class leading EPA claim of 

 

10CFU per ml HPC purity; that’s 50 times lower than the acceptable standard set forth by CDC and ADA. In 

addition, the G5 is the only dental water system in the world to feature Class A ultraviolet (UV) irradiation capable 

of killing 99.99% of bacteria and viruses.

*

 That’s class leading disinfection without tablets or daily additives and 

only 10 minutes of annual maintenance. 

Integrated smart technology allows for live, 24/7 monitoring and alerts accessed anytime via the PC app or 

touchscreen enables the user to see real time data from a network of on-board sensors for convenient system 

health monitoring. In the event of a maintenance alert, users can access built-in troubleshooting guides 

pertaining to their specific error for quick and easy resolution.

835 S Highway 105 Suite D

Palmer Lake, CO 80133

Office:  719 622 7200

Fax: 

866 299 2495

Sterisil offers optional add-ons to the G5 to ensure proper performance. Installation of these items can be found 

on page 14. Optional add-ons are called out in each relevant section by the color purple. Specific requirements 

for add-ons must be understood before starting the installation.

* Chevrefils, G., B.Ing, Caron, E., B.Sc., Wright, H., Sakamoto, G., Payment, P., Barbeau, B., & Cairns, B. (2006). UV Dose Required to 

Achieve Incremental Log Inactivation of Bacteria, Protozoa and Viruses. IUVA News,8, 1st ser., 38-45.

Optional Add-On Components

In-Wall Dispensing Station

(14”L x 4”W x 30”H”) space, within 50’ from the 

System

Sterisil

®

 Wand

Autoclave must be within 10’ from the System

Pre-filter Kit

(5”Dia x 12”H), Suggested use with source water 

quality > 250 PPM TDS

Booster Pump

(4”Dia x 7”H), Suggested use with source water 

pressure < 60 PSI

BOTTLE FILL AND DIRECT FEED COMPARISON 

The G5 can be configured for independent bottle reservoirs or municipal direct feed depending on the office 

configuration. Throughout this manual, designated sections specific to the direct feed configuration will be 

highlighted in blue with the blue triangle icon. Pay specific attention to the plumbing of dental water with direct 

feed systems as they are significantly different from their bottle fill counterparts.

IMPORTANT 

Sections marked with the red triangle icon contain information that must be taken into consideration before 

install.

Содержание System G5

Страница 1: ...INSTALLATION AND MAINTENANCE MANUAL GP9003 A ...

Страница 2: ...the user to see real time data from a network of on board sensors for convenient system health monitoring In the event of a maintenance alert users can access built in troubleshooting guides pertaining to their specific error for quick and easy resolution 835 S Highway 105 Suite D Palmer Lake CO 80133 Office 719 622 7200 Fax 866 299 2495 Sterisil offers optional add ons to the G5 to ensure proper ...

Страница 3: ...r go to the settings tab on the touchscreen Record the installation date on the warranty card Please ensure you send in the warranty card or register online The initial set up can take up to 3 5 hours depending on customer specifications Ensure the lengths of tubing provided will meet the needs of your specific configuration All tubing cuts should be made at a right angle to the tubing itself Be s...

Страница 4: ...of mounting the system Sterisil recommends anchoring the system into a wall stud The EZ toggle anchors should only be used when drilling into drywall STATIC MOUNT BAG B 1 Affixing the Static Plate to the Wall Identify the slotted holes on the plate These slots will be used to mount the plate to the wall The static plate is symmetrical so any side can be up Mock up your static mounting plate in the...

Страница 5: ...ERIPHERAL COMPONENTS Peripheral components No more than 50 feet from the system Depending on the customer s specific configuration you may have optional components such as the Pre filter Kit and Booster Pump plumbed between the municipal source and the red SOURCE port on the system G5 POWER ADAPTER Select location within 6 feet of the outlet Ensure there is no tension on the cable If you choose to...

Страница 6: ... D Tank Port Blue fitting Indicator Run 1 4 tubing from the blue DENTAL port on the system to the 1 4 Tank Ball Valve on the smaller dental water storage tank Autoclave Port Green fitting indicator OPTIONAL ADD ON Sterisil Wand see page 14 Run 1 4 tubing from the green AUTOCLAVE port on the system to the white Autoclave Faucet Drain Port Black fitting indicator Bag D Run a 1 4 line from the black ...

Страница 7: ...DD ONS PRE FILTER KIT OPTIONAL COMPONENT Considerations Account for a minimum of 2 clearance at the bottom for future filter replacements Location of Pre filter and Inline Ball Valve diagram is on page 5 Turn off your source water Find a location where you can drive the screws for the bracket into the wall that will reach both your source water line and your Sterisil System G5 source line If you h...

Страница 8: ...for 60 seconds For change outs on Stages 1 4 close the RO tank and run the autoclave water For Stage 5 change outs close the Dental Storage Tank and run the dental water Stage 5 7 Open all tanks to finish 8 Cartridges can either be discarded in the trash or returned to Sterisil for recycling For more information on our recycling program visit sterisil com recycle Make a clean square cut on the sou...

Страница 9: ...ed Sterisil Cartidges by a click of a button Simply visit sterisil com green or call us directly to request a free shipping label While other companies dispose 100 of their used products to a landfill Sterisil is able to recycle 91 of our Straws and Cartridges In addition to recycling Sterisil contributes to a greener environment by being the only dental waterline company to offer a residual disin...

Отзывы: