Operational Test
Uncrating/Installation Instructions
122997-217
5.1
Start-Up Test
Procedures
See Figure 5-1.
1.
Ensure storage hopper is filled with bedding.
2.
Position
Power ON/OFF
selector switch to
ON
.
3.
Pull
Unit STOP
pushbutton (red) to start conveyor.
4.
After pulling
Unit STOP
pushbutton, wait two seconds and push
Dispenser ON/OFF
pushbutton to activate bedding dispenser
system.
5.
Press
Dust Collector ON/OFF
pushbutton to activate dust col-
lection system.
6.
If necessary, adjust amount of bedding desired in cages using
Dispenser Adjustment
knob to increase/decrease bedding flow.
7.
Position a few cages top side up on load-end conveyor.
NOTE: Cages of cage flip-over system are automatically flipped
from inverted position to top side up position when exiting Basil
®
6700 Tunnel Cage Washer.
8.
Let bedding dispenser run for a few minutes.
9.
Verify rotation of conveyor motors. Motors should turn in direc-
tion shown by arrow. If motors are rotating in wrong direction,
disconnect main power, reverse any two three-phase wires and
verify shaft rotation again.
10. Verify rotation of dust collection motor fan. Fan should rotate
clockwise (in same direction as outlet of blower casing). If fan
motor is rotating in wrong direction, disconnect main power,
reverse any two three-phase wires and verify shaft rotation
again.
11. Adjust cage size for cage flip-over system as follows:
a.
Remove two 10-32 screws.
b. Move adjustment rod to one of the four positions available
IMPORTANT:
Adjustment rod must be installed in the same
position on each side of cage flip-over module.
12. Position
Power ON/OFF
selector switch to
OFF
position. Verify
bedding dispenser conveyor operation stops.
IMPORTANT:
A listing of the Safety Precautions to be observed when uncrating/installing and testing this
bedding dispenser can be found in S
ECTION
1 of this manual. Do not begin uncrating/installing the
equipment until you have become familiar with this information.
WARNING – PERSONAL INJURY
AND/OR EQUIPMENT DAMAGE
HAZARD: Fans and motors
have rotating parts and pinch
points. When operating a unit
equipped with dust collection
system, ensure exhaust guard,
elbow and dust bag are
securely in place.
WARNING – ELECTRIC SHOCK
AND/OR BURN HAZARD: Dis-
connect all utilities to dis-
penser before servicing. Do not
service dispenser unless all
utilities have been properly
locked out. Always follow local
lockout-tagout and electrical
safety-related work practice
standards.
CAUTION – POSSIBLE EQUIP-
MENT HAZARD: Once electri-
cal power is connected, verify
each motor for correct rota-
tion. Incorrect motor rotation
may result in equipment dam-
age and improper equipment
operation.
OPERATIONAL TEST