3-5
Installation Instructions
Uncrating/Installation Instructions
122997-217
3.5 Connect Utilities
See Figure 3-4.
1.
Connect conveyor motor as per Figure 3-4.
2.
Connect dust collection system electrical supply line from unit to
dust collection motor, securing connections with wire nuts:
•
Red wire with T1
•
Black wire with T2
•
Blue wire with T3
3.
If bedding dispenser is to be used with a Basil
®
6700 Tunnel
Cage Washer
, make following wire connections:
a.
Secure wire conduit located at unload end of Basil 6700
Tunnel Cage Washer in bedding dispenser electrical box.
b. Connect wires to their corresponding (numbered) terminal in
bedding dispenser electrical box.
4.
Knocked-down shipment and photoelectric conveyor stop:
a.
Secure wire conduit of photoelectric sensor in bedding
dispenser electrical box.
b. Connect wires to their corresponding (numbered) terminals
in bedding dispenser electrical box.
WARNING – PERSONAL INJURY
AND/OR EQUIPMENT DAMAGE
HAZARD: Repairs and adjust-
ments to this equipment must be
made only by STERIS or
STERIS-trained service person-
nel. Non-routine maintenance
performed by unqualified per-
sonnel or installation of unau-
thorized parts could cause
personal injury, result in
improper equipment perfor-
mance, void the warranty or
result in costly damage. Contact
STERIS regarding service
options.
WARNING – ELECTRIC SHOCK
AND/OR BURN HAZARD: Fas-
teners and star washers are
used to ensure protective bond-
ing continuity. Always reinstall
any star washer which may have
been removed during installa-
tion or servicing.
Figure 3-4. Conveyor Motor Wiring