background image

ENGLISH

ENGLISH-4

MEASURING METHODS
MEASURING DC / AC

1.- Connect the red testing point to the jack signaled “V 

Ω

 mA” 

and the black testing point to the jack signaled “COM”.
2.- Set the dial to the VDC / VAC setting 
3.- When the value to be measured is unknown, set the dial to 
the maximum setting.  Reduce level by level until reaching the 
desired level.
4.- Connect the testing points to the equipment to be measured.
5.- Turn the equipment to be measured on, the voltage will 
appear on the LCD screen.  The polarity will also appear.

MEASURING DC AMPS

1.- Connect the red testing point to the jack signaled “V

Ω

mA”, 

and the black testing point to the jack signaled “COM”. When 
measuring up to 200 mA connect the red testing point to  the jack 
signaled “10ADC” when measuring up to 10A.
2.- Set the dial to the VAC setting
3.- Open the circuit and connect the testing points (in serial) to 
the equipment to be measured.
4.- read the value in the LCD screen.

MEASURING RESISTANCE 

1.- Connect the red testing point to the jack signaled “V

Ω

mA” 

and the black testing point to the jack signaled “COM”.
2.- Set the dial to Ohms (

Ω

) range.

3.  If the measured resistance is connected to a circuit, turn it off 
and discharge the capacitors before to measure.
4.- Connect the testing points to the circuit to be measured.
5.- The resistance value will appear on the LCD screen.

MEASURING DIODES

1.- Connect the red testing point in the jack signaled “V 

Ω

” and 

the black testing point in the jack signaled “COM”.
2.- Set the dial to the          range.
3.- Connect the red testing point to the diode to be measured 
and the black testing point to the cathode.
4.- The voltage will appear on the LCD screen in m Volts.

MEASURING TRANSISTORS –hFE-

1.-  Set the dial to the hFE range.

Содержание MUL-055

Страница 1: ......

Страница 2: ...common for inserting the black testing point negative V mA to insert the red testing point positive to measure voltage resistance and current up to 200mA If you want to measure up to 10A move the tes...

Страница 3: ...st overcharge maximum 15 seconds at 220V rms then the alarm sounds INSTRUCTIONS WARNING 1 Do not introduce DC voltages above 500 V in order to avoid electrical shocks 2 Before to use the meter check t...

Страница 4: ...ring up to 10A 2 Set the dial to the VAC setting 3 Open the circuit and connect the testing points in serial to the equipment to be measured 4 read the value in the LCD screen MEASURING RESISTANCE 1 C...

Страница 5: ...needs to be replaced and when it does it is usually due to an error in operation If BAT appears on your LCD screen the battery needs to be replaced To replace the battery and the fuse 200mA 250 V rem...

Страница 6: ......

Страница 7: ...n zinc 1 x 9 V Bot n para retenci n de datos HOLD Dimensiones 145 x 76 x 40 mm Entradas 3 conectores hembra Jack Com n para insertar la punta de prueba color negro negativa V mA para insertar la punt...

Страница 8: ...V rms en todos los rangos PRUEBA DE CONTINUIDAD AUDIBLE Protecci n contra sobrecarga 15 segundos m ximo a 220 V rms suena la alarma Rango Resoluci n Precisi n 200V 100mV 1 25 de rgd 10d 600V 1V 1 25...

Страница 9: ...medici n 4 Encienda el dispositivo o circuito que va a medir el valor del voltaje aparecer en la pantalla display digital con la polaridad adelante MEDICION DE AMPERAJE DE CD 1 Coloque la punta de pr...

Страница 10: ...LE 1 Coloque las puntas de prueba roja en V mA y negra en COM 2 Coloque el selector en la posici n de 3 Conecte las puntas a los puntos del circuito a ser medido Si la resistencia es menor de 100 Ohms...

Страница 11: ...ual de Operaci n Puntas de Prueba Bater a de Cortes a Las caracter sticas del equipo pueden ser modificadas sin previo aviso ESPA OL ESPA OL 6 Las caracter sticas del equipo pueden ser modificadas sin...

Страница 12: ...es to costumer as well as warranty service at any of the addresses mentioned later THIS WARRANTY IS VOID IN THE NEXT CASES If the product has been damaged by an accident acts of God mishandling leaky...

Страница 13: ...EFECTIVA EN LOS SIGUIENTES CASOS 1 Cuando el producto ha sido utilizado en condiciones distintas a las normales 2 Cuando el producto no ha sido operado de acuerdo con el instructivo de uso 3 Cuando e...

Отзывы: