background image

10

10

Range 

Resolution 

Accuracy 

200 Ω

0.1 Ω

 

2 kΩ

1 Ω

± (0.5% ± 1 digit)

20 kΩ

10 Ω

± (0.5% ± 1 digit)

200 kΩ

100 Ω

± (0.5% ± 1 digit)

2 MΩ

1 kΩ

± (0.5% ± 1 digit)

20 MΩ

10 kΩ

± (1.0% ± 2 digits)

Protection against overchange: 220VDC or AC rms for all ranges.

Open circuit voltage: 750 mv.

Humidity: 0-75%, 0-35°C en 2 MΩ y 20 MΩ, 0-90%, 0-35°C in any other range.

Testing diodes 

1. Connect the red testing probe to the jack signaled “V/Ω” and the black testing 

probe to the jack signaled “COM”.

2. Select the function 

 and realize the measurements.  

• If one of the testing probes is not connected to the circuit, the LCD screen will 

display “1”, indicating an over range.

•  When  you  use  this  function,  through  the  testing  element  circulates  a  1  mA            

current, approximately.

Содержание MUL-050

Страница 1: ......

Страница 2: ...c mo utilizar apropiadamente el producto Para apoyo compras y todo lo nuevo que tiene Steren visite nuestro sitio web www steren com MULT METRO DIGITAL ECON MICO CON PRUEBA DE TRANSISTORES La informa...

Страница 3: ...n por sobrecarga e indicador audible para mediciones incorrectas IMPORTANTE Nunca conecte el mult metro a m s de 1000 V de CD o 750 Vrms de CA Nunca use un rango inapropiado ya que podr a da ar los c...

Страница 4: ...Entradas V COM 2 A y 10 A E B C E PNPN PN E B C E 200 2K ON OFF h 2M 20M 20K 200K V C E PNPN PN C E 200m 200m 200m 200m 200 200 200 200 200 20 20 20 20 20 20 20m 20m 2 2K OFF hFE 2M 20M 20K 200K 2 2m...

Страница 5: ...1 quiere decir que el voltaje que se est midiendo excede el rango seleccionado por lo tanto elija uno m s alto Si no sabe el valor del voltaje a medir se recomienda usar el rango m s alto No rebase l...

Страница 6: ...si n 200 mV 100 V 0 5 de lectura 1 d gito 2 V 1 mV 0 5 de lectura 1 d gito 20 V 10 mV 0 5 de lectura 1 d gito 200 V 100 mV 0 5 de lectura 1 d gito 1000 V 1 V 0 5 de lectura 1 d gito VOLT METRO CA V Ra...

Страница 7: ...0 V Rango de frecuencia 40 Hz a 1000 Hz Rango m ximo de corriente 20 A m x 15 s Ca da de voltaje 200 mV Medici n de Amperaje Protecci n contra sobrecarga fusible de 2 A 250 V Rango m ximo de corriente...

Страница 8: ...i n est protegida por un fusible de 2 A 250 V sin embargo ponga especial atenci n en el rango de 20 A ya que ste no se encuentra protegido Cuando se usa este rango la lectura m xima debe ser de 20 A p...

Страница 9: ...obrerrango y en la pantalla aparecer 1 por lo tanto debe seleccionar un rango m s alto Para valores de 1 M o m s puede tardarse algunos segundos en estabilizarse lo cual es normal 5 Desconecte los cir...

Страница 10: ...ircuito abierto 750 mv Humedad 0 75 0 35 C en 2 M y 20 M 0 90 0 35 C en cualquier otro rango Medici n de diodos 1 Conecte la punta roja a V mA y la negra a COM La polaridad de la punta roja ser positi...

Страница 11: ...menor a 30 Medici n de continuidad audible 1 Conecte la punta roja a V y la negra a COM 2 Coloque la perilla en la posici n 200 3 El medidor sonar si la resistencia entre las puntas es igual o menor...

Страница 12: ...stor es y localice el emisor la base y el colector El medidor mostrar la lectura aproximada de hFE en una corriente de base lb 10 A y Vce 2 8 V 5 CAMBIO DE BATER A 1 Si en la pantalla aparece LOBAT o...

Страница 13: ...00 A a 20 A Corriente alterna 200 A a 20 A Pantalla de 3 d gitos Precisi n en CD de 0 5 Rango completo ajuste autom tico a cero sobrerrango y bater a baja Resoluci n de 0 1 A para peque as corrientes...

Страница 14: ...la propia casa comercial donde adquiri el producto Si la presente garant a se extraviara el consumidor puede recurrir a su proveedor para que le expida otra p liza previa presentaci n de la nota de co...

Страница 15: ......

Страница 16: ...ease review this manual thoroughly to ensure proper installation and operation of this product For support shopping and everything new at Steren visit our website www steren com DIGITAL MULTIMETER The...

Страница 17: ...ent measures Protection against over charge IMPORTANT Do not introduce DC voltages above 1000 VDC or AC voltage above 750 VAC Never use an inappropriate range it would damage the internal circuits Nev...

Страница 18: ...ks V COM 2 A and 10 A E B C E PNPN PN E B C E 200 2K ON OFF h 2M 20M 20K 200K V C E PNPN PN C E 200m 200m 200m 200m 200 200 200 200 200 20 20 20 20 20 20 20m 20m 2 2K OFF hFE 2M 20M 20K 200K 2 2m 2m 2...

Страница 19: ...reading 1 means that the voltage being measured exceeds the select range therefore choose a higher If you don t know the voltage value to be measured you should use the highest rank Don t exceed while...

Страница 20: ...th a maximum value of 225 Vrms Range Resolution Accuracy 200 mV 100 V 0 5 1 digit 2 V 1 mV 0 5 1 digit 20 V 10 mV 0 5 1 digit 200 V 100 mV 0 5 1 digit 1000 V 1 V 0 5 1 digit AC VOLTAGE V Range Resolut...

Страница 21: ...2A 250 V fuse Frequency range 40 Hz to 1000 Hz Maximum current range 20 A max 15s Voltage loss 200 mV Measuring amperage Protection against overchange 2A 250 V fuse Maximum current range 20 A max 15s...

Страница 22: ...V for readings between 2 A and 20 A maximum 10 seconds with 20 A and the black to the jack signaled COM 2 Turn the knob to the maximum setting and reduce level by level depending on the reading This f...

Страница 23: ...easured exceeds the range selected this will be an overange condition and will read on the dispay 1 therefore select a higher range For values of 1 M or more can take several seconds to stabilize This...

Страница 24: ...0 75 0 35 C en 2 M y 20 M 0 90 0 35 C in any other range Testing diodes 1 Connect the red testing probe to the jack signaled V and the black testing probe to the jack signaled COM 2 Select the functio...

Страница 25: ...8 VDC Audible if the resistance is under 30 Measuring audible continuity 1 Connect the red testing probe in V and the black testing probe in COM 2 Set the knob to 200 3 If the resistance is less than...

Страница 26: ...PNP and localize the emiter base and collector The meter will show the approximate hFE value with base current condition of 10 A and Vce 2 8 V 5 BATTERY CHANGE 1 If one battery have not enough energy...

Страница 27: ...rrent 200 A to 20 A CA current 200 A to 20 A Screen 3 digits Accuracy 0 5 CD Full range automatic zero overrange and low battery Resolution of 0 1 A for small currents Protection against overload and...

Страница 28: ...warranty service at any of the addresses mentioned later THIS WARRANTY IS VOID IN THE NEXT CASES If the product has been damaged by an accident acts of God mishandling leaky batteries failure to foll...

Страница 29: ......

Отзывы: