© Guldmann GB/US-1412/01/18 • # 30901020

Heating cable .

 Lifting platforms installed outdoors are normally fitted with a 

heating cable of 220 Watt. This should be left on whenever there is a danger 

of frost.

The following points must be adhered to:

 

•  There is a risk of getting jammed at the moving parts of the platform, for 

instance the automatic doors.

•  Fingers must not be placed in the gaps in the lifting platform’s columns/tower 

as this can lead to them being crushed.

•  Parts and components must not be removed from the lifting platform.

•  Contact the supplier in the event of faults or defective components. Use only 

original spare parts.

•  The control panel must not be covered.

•  Signs must not be removed or covered.

•  Great care must be taken in the winter because of the risk of slipping on the 

lifting platforms floor and access ramp.

•  Great care must be taken when using the emergency lowering device.

6 .00  

Maintenance

Exercise caution while working beneath the platform, as a crush hazard may 

arise between the platform’s moving parts. 

Important!

 A blocking beam must always be used while working beneath the 

platform.

The following safety advice must be adhered to:

•  Run the platform all the way to the upper level. 

•  Next, disconnect the platform’s power source in 

order to prevent the risk of electrical shock and 

crushing.

•  Insert the blocking beam beneath the platform 

beside the left post, as shown in the drawing. It 

is now safe to work beneath the platform. 

•  The lifting platform may NOT be raised/lowered 

while work is being performed beneath the 

platform. This rule applies even if the blocking 

beam or other safety devices are in place.

•  Only one person is allowed to work on the lifting platform once it has been 

installed, connected and can be raised/lowered. 

 

Содержание LP8

Страница 1: ...GB US LP8 Lifting platform Vers 4 00...

Страница 2: ...2 02 Operating Instructions 6 2 03 Markings and symbols on the product 8 3 00 Connections 9 3 01 Electrical connections 9 4 00 Installation of accessories 10 5 00 Safety measures 10 6 00 Maintenance 1...

Страница 3: ...form is designed and produced in accordance with current standards for negotiating height differences of up to 3 metres Great importance is attached to the design and implementation to achieve attract...

Страница 4: ...s electronic parts that must also be disposed of in accord ance with applicable regulations 1 03 Important warnings Read the instructions carefully before using the product The LP8 must be assembled b...

Страница 5: ...20 1 04 Components 1 Lower door 2 Upper door 3 Access ramp 4 Control panel 5 Emergency lowering valve behind cover adjusting screw for emergency lowering 6 Production sign 7 Tower 8 Lift basket 9 Base...

Страница 6: ...at the lower level after use Operating instructions 1 Ensure that no one is situated at the doors as the doors open and close automatically 2 UP Press and hold the Up button in until the lifting platf...

Страница 7: ...red button until the platform reaches the lower level 3 The lower door can be opened when the lifting platform is in the lower posi tion 4 If the emergency lowering device has been used the cause must...

Страница 8: ...and inside the lift basket Emergency lowering instructions On the motor housing 1 The emergency lowering device is available behind the hatch 2 Ensure that no one is under the platform as the safety...

Страница 9: ...ly must be con nected to the terminal block located in a switch box in the motor housing The heating cable if mounted is also connected to the terminal block The heating cable can with advantage be eq...

Страница 10: ...tric cable of 3 metres Perforated steel Side plates of lift basket and doors are available in perfo rated steel instead of glass Remote control As an option the lifting platform can be supplied with i...

Страница 11: ...The emergency lowering device is locked in and is placed in the motor housing which is either behind the lifting platform or at the side depending on the cus tomer s requirements and available space...

Страница 12: ...ping on the lifting platforms floor and access ramp Great care must be taken when using the emergency lowering device 6 00 Maintenance Exercise caution while working beneath the platform as a crush ha...

Страница 13: ...and thereby preventing the lifting platform from going all the way down Cleaning The lifting platform can be cleaned with soap and water NB High pressure washers and scourers cannot be used Service in...

Страница 14: ...The emergency lowering device has been used Turn the adjusting screw for emergency lowering to its original position The lifting platform shows overload Remove some of the load from the lifting platfo...

Страница 15: ...parts Frequency 50Hz Phases 1 phase Circuit 10A fuses Voltage 230 Volt Control power 24 Volt Heating cable 220 Watt Doors Door motor 24 Volt DC Motor unit AC motor 1 1kW 230 Volts 1400 r min Operating...

Страница 16: ...the equipment which has been sub ject to damage or abuse by the user or others The warranty does not cover any part of the equipment which has been altered or changed in any way by the user or others...

Страница 17: ...17 Guldmann GB US 1412 01 18 30901020...

Страница 18: ...18 Guldmann GB US 1412 01 18 30901020...

Страница 19: ...19 Guldmann GB US 1412 01 18 30901020...

Страница 20: ...V Guldmann A S Tlf 45 8741 3100 Fax 45 8741 3131 E mail info guldmann com www stepless com Guldmann GB US 1412 01 18 30901020...

Отзывы: