Chapter 5 Ratings
5 - 9
5.4 Recommended Soldering Conditions
(1) Product storage conditions: T
A
= 40
°
C max., RH = 85% for prevention of moisture
absorption
(2) Manual soldering: Temperature of the tip of soldering iron 380
°
C, 5 s max.
(Device lead temperature 260
°
C, 10 s max., package surface temperature 150
°
C)
(3) Reflow: Twice max.
(4) Flux: Non-chlorine flux (should be cleaned sufficiently)
(5) Ultrasonic cleaning: Depending on frequencies and circuit board shapes, ultrasonic
cleaning may cause resonance, affecting lead strength
5.5 Recommended Reflow Conditions
The recommended conditions apply to hot-air reflow or infrared reflow. Temperature indi-
cates resin surface temperature of the package.
Parameter
Symbol
Reflow
Manual soldering iron
Peak temperature (resin surface)
Tp
255
°
C max.
380
°
C max.
Peak temperature holding time
tp
10 s max.
5 s max.
Parameter
Symbol
Value
Pre-heat (time)
t1
60 to 80/s
Pre-heat (temperature)
T1
150 to 190
°
C
Temperature rise rate
a
1 to 4
°
C/s
Peak condition (time)
tp
10 s max.
Peak condition (temperature)
Tp
255
°
C
Cooling rate
b
to 1.5
°
C/s
Cooling rate
c
to 0.5
°
C/s
High temperature area
tw
220
°
C, 60 s max.
Removal temperature
T2
≤
100
°
C
Содержание MKY02
Страница 1: ...HUB IC MKY02 User s Manual for Hi speed Link System STD HLS02 V1 7E...
Страница 8: ...MKY02 User s Manual for Hi speed Link System viii...
Страница 10: ......
Страница 23: ...Chapter 1 Concepts for Using MKY02 HUB 1 15...
Страница 24: ...MKY02 User s Manual for Hi speed Link System 1 16...
Страница 26: ......
Страница 32: ......
Страница 48: ...MKY02 User s Manual for Hi speed Link System 3 18...
Страница 50: ......
Страница 58: ...MKY02 User s Manual for Hi speed Link System 4 10 4 3 Example Circuit for Port added HUB by Cascade Connection...
Страница 60: ...MKY02 User s Manual for Hi speed Link System 4 12...
Страница 62: ...MKY02 User s Manual for Hi speed Link System 4 14...
Страница 64: ......
Страница 70: ...MKY02 User s Manual for Hi speed Link System 5 8 5 3 Package Dimensions...