Operating Modes
The Stentorfield Revive has three modes of operation, indicated by the LED located
on the front panel of the machine.The operating modes are:
1.
Standby Mode: When in standby mode the machine is idle, ready to make a
vend.This indicated by the LED showing green.
2.
Boiler Filling/Heating Mode: The boiler/filling mode is indicated by the LED
flashing red and green.
3.
Low Water Mode: The low water mode (indicated by the LED glowing red)
occurs when the boiler fill routine has timed out due to insufficient mains water
supply.
Accessing the Audit Display
Access to the audit display is gained by pressing the green and red push buttons located
on the LCD board.The board is mounted on the rear of the door and covered with a
panel which allows access to the programming buttons and messages on the LCD to
be viewed.
Caution: Do not remove this panel.
Referring to the illustration, proceed as follows:-
Ensure machine is connected to the mains electricity supply and on/off switch located
on the rear of the machine is switched on.
1. Press the red button (1) to access the audit program.
2. Press the green button (2) to enter the audit sub-program.
3. Press the green button to view drink 1 audit, displayed in the LCD display (3).
4. Use the red button to step through the program. When the required drink is
displayed, press the green button to view audit data.
Operator’s Manual
10
1
2
3