www.stenner.com
6
OUTPUT AND SIZING CHARTS
NOTICE:
The information within these charts is solely intended for use as a guide. The output data is an approximation based
on pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
Approximate Maximum Output @ 50/60Hz
Approximate Maximum Output @ 50/60Hz
ALTERNATIVE SIZING – M07 Model using 1 pulse/gallon meter
Dosage
Dosage Ratio
Max. System Water Flow
Pulse Setting
oz/gal
gal/min
1.0
1:128
3.5
1
0.50
1:256
7.0
2
0.25
1:512
14.0
4
NOTE: 1 oz = 29.57 ml; 1 gallon = 3.78 liters. Contact factory for assistance with sizing.
NOTE: Injection check valve included with pumps rated 100 psi (6.9 bar) maximum.
FLOW RATE OUTPUT CHART – 25 psi (1.7 bar) maximum
Model
Item Number
Pump Tube
Ounces
Gallons
Gallons
Milliliters
Liters
Liters
Prefix
per Minute per Hour per Day
per Minute per Hour per Day
M05
M05
5
8.4
3.9
95
249.7
14.9
359.6
Maximum system water flow for 1:128 dosing is 8.4 gallons/minute or 31.8 liters/minute.
FLOW RATE OUTPUT CHART – 100 psi (6.9 bar) maximum
Model
Item Number
Pump Tube
Ounces
Gallons
Gallons
Milliliters
Liters
Liters
Prefix
per Minute per Hour per Day
per Minute per Hour per Day
M07
M07
7
3.5
1.6
40
105
6.3
151.4
Maximum system water flow for 1:128 dosing is 3.5 gallons/minute or 13.2 liters/minute.