INSTALL SUCTION LINE TO PUMP HEAD
1.
Uncoil the suction/discharge line. Use outside of solution tank as a guide to cut
proper length of suction line ensuring it will be 2-3" above the bottom of solution tank.
Allow sufficient slack to avoid kinks and stress cracks. Always make a clean
square cut to assure that the suction line is burr free. Normal maintenance
requires trimming.
Suction lines that extend to the bottom of the tank can result in debris pickup
leading to clogged injectors and possible tube failure.
2.
Make connections by sliding the line(s) through connecting nut and ferrule and finger
tighten to the corresponding tube fittings.
3.
Finger tighten nut to the threaded tube fitting while holding the tube fitting.
Over tightening the ferrule and nut with a wrench may result in damaged fittings,
crushed ferrules, and air pick up.
DO NOT use thread seal tape on pump tube connections or tools to
tighten connections.
DO NOT use thread
seal tape on pump
tube threads.
DO NOT
use pliers.
Suction Line
Finger tighten 1/4" nut
Discharge Line
Connecting Nut
NOTE: Beveled ends of ferrules
face pump. Suction line should
bottom into all fittings.
Ferrule