9
USA and Canada 800.683.2378, International 904.641.1666
Econ LD
Item
Number
Pump
Roller
Approximate
Ounces
Pressure
Milliliters Pressure
Prefix
Tube
Assembly
Turndown
Ratio
per Hour
psi
per Hour
bar
E10LHM
M
White
50:1
0.04–2.4
80
1.3–70.0
5.5
E10LHF
F
White
50:1
0.11–8.1
80
3.2–240.0
5.5
Approximate Outputs @ 50/60Hz
FLOW RATE OUTPUTS
The output on the variable speed pump can be adjusted
via the potentiometer on the side of the pump.
Turning the potentiometer fully counterclockwise turns
the pump off.
Turning the potentiometer clockwise gradually increases
the speed to 100% at the full clockwise position.
Graduations are approximate.
DO NOT set
potentiometer in
gray area of scale
NOTICE:
The information within this chart is solely intended for use as a guide. The output data is an approximation based on
pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump
Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
NOTE: Injection check valve included with pumps rated 80 psi (5.5 bar) maximum.