background image

LIMITED WARRANTY

Stenner Pump Company will for a period of one (1) year from the date of purchase (proof
of purchase required) repair or replace – at our option – all defective parts. Stenner is not
responsible for any removal or installation costs. Pump tube assemblies and rubber
components are considered perishable and are not covered in this warranty. Pump tube
will be replaced each time a pump is in for service, unless otherwise specified. The cost of
the pump tube replacement will be the responsibility of the customer. Stenner will incur
shipping costs for warranty products shipped from our factory in Jacksonville, Florida. Any
tampering with major components, chemical damage, faulty wiring, weather conditions,
water damage, power surges, or products not used with reasonable care and maintained in
accordance with the instructions will void the warranty. Stenner limits its liability solely to
the cost of the original product. We make no other warranty expressed or implied. 

RETURNS

Stenner offers a 30-day return policy on factory direct purchases. Except as otherwise
provided, no merchandise will be accepted for return after 30 days from purchase. To
return merchandise at any time, call Stenner at 800.683.2378 for a Return Merchandise
Authorization (RMA) number. A 15% re-stocking fee will be applied. Include a copy of your
invoice or packing slip with your return.

DAMAGED OR LOST SHIPMENTS

Check your order immediately upon arrival. All damage must be noted on the delivery
receipt. Call Stenner Customer Service at 800.683.2378 for all shortages and damages
within seven (7) days of receipt.

SERVICE & REPAIRS

Before returning a pump for warranty or repair, remove chemical from pump tube by
running water through the tube, and then run the pump dry. Following expiration of the
warranty period, Stenner Pump Company will clean and overhaul any Stenner metering
pump for a minimum labor charge plus necessary replacement parts and shipping. All
metering pumps received for overhaul will be restored to their original condition. The
customer will be charged for missing parts unless specific instructions are given. To return
merchandise for repair, call Stenner at 800.683.2378 or 904.641.1666 for a Return
Merchandise Authorization (RMA) number.

DISCLAIMER

The information contained in this manual is not intended for specific application purposes.
Stenner Pump Company reserves the right to make changes to prices, products, and
specifications at any time without prior notice.

TRADEMARKS

Santoprene

®

is a registered trademark of Exxon Mobil Corporation.

AquaShield

is a trademark of Houghton International.

3

USA and Canada 800.683.2378, International 904.641.1666

Econ LD

WARRANTY AND CUSTOMER SERVICE

Содержание ECON LD

Страница 1: ... INSTALLATION AND MAINTENANCE MANUAL PERISTALTIC METERING PUMPS SINCE 1957 TO BE INSTALLED AND MAINTAINED BY PROPERLY TRAINED PROFESSIONAL INSTALLER ONLY READ MANUAL LABELS FOR ALL SAFETY INFORMATION INSTRUCTIONS WARNING ...

Страница 2: ...6 9 12 14 18 20 22 24 Materials of Construction 7 Accessory Checklist 8 Flow Rate Outputs 9 10 Installation 11 17 Troubleshooting 18 20 Tube Replacement 21 23 Cleaning the Point of Injection 24 26 Exploded View and Parts 27 28 Mounting Template 29 IMELD 031017 TABLE OF CONTENTS ...

Страница 3: ...ization RMA number A 15 re stocking fee will be applied Include a copy of your invoice or packing slip with your return DAMAGED OR LOST SHIPMENTS Check your order immediately upon arrival All damage must be noted on the delivery receipt Call Stenner Customer Service at 800 683 2378 for all shortages and damages within seven 7 days of receipt SERVICE REPAIRS Before returning a pump for warranty or ...

Страница 4: ...duce the risk of injury do not permit children to use this product unless they are closely supervised at all times 3 WARNING Risk of Electric Shock Connect only to a branch circuit protected by a ground fault circuit interrupter GFCI Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI 4 WARNING To reduce the risk of electric shock replace damaged cord im...

Страница 5: ...ée par un dispositif à courant différentiel résiduel RCD fonctionnant à 30 mA DO NOT alter the power cord or plug end DO NOT use receptacle adapters DO NOT use pump with a damaged or altered power cord or plug end Contact the factory or an authorized service facility for repair HAZARDOUS VOLTAGE DISCONNECT power cord before removing motor cover for service Electrical service by trained personnel o...

Страница 6: ...nstallation and product must adhere to all regulatory and compliance codes applicable to the area This is the safety alert symbol When displayed in this manual or on the equipment look for one of the following signal words alerting you to the potential for personal injury or property damage Acceptable for indoor and outdoor use Acceptable pour une utilisation aussi bien à l intérieur qu à l extéri...

Страница 7: ...Rollers Polyethylene Check Valve Duckbill Santoprene FDA approved Suction Discharge Tubing Ferrules Polyethylene FDA approved Suction Line Strainer PVC NSF listed with ceramic weight Tube Injection Fittings PVC or Polypropylene NSF listed Connecting Nuts PVC NSF listed All Fasteners Stainless Steel Santoprene is a registered trademark of Exxon Mobil Corporation ...

Страница 8: ...Contents 3 Connecting Nuts 1 4 3 Ferrules 1 4 or 6 mm Europe 1 Injection Check Valve 1 Weighted Suction Line Strainer 1 4 1 20 Roll of Suction Discharge Tubing 1 4 White or UV Black OR 6 mm White Europe 1 Additional Pump Tube 1 Installation Manual ...

Страница 9: ...r fully counterclockwise turns the pump off Turning the potentiometer clockwise gradually increases the speed to 100 at the full clockwise position Graduations are approximate DO NOT set potentiometer in gray area of scale NOTICE The information within this chart is solely intended for use as a guide The output data is an approximation based on pumping water under a controlled testing environment ...

Страница 10: ... on or near a metering pump Install the pump so that it is in compliance with all national and local plumbing and electrical codes Use the proper product to treat potable water systems use only additives listed or approved for use Inspect tube frequently for leakage deterioration or wear Schedule a regular pump tube maintenance change to prevent damage to pump and or spillage Pump is not recommend...

Страница 11: ... NOT mount pump directly over an open solution tank Keep tank covered Avoid flooded suction or pump mounted lower than the solution container Draw solution from the top of the tank Pump can run dry without damage If pump is installed with a flooded suction a shut off valve or other device must be provided to stop flow to pump during service To prevent motor damage verify with a volt meter that the...

Страница 12: ... position verticale selon le dessin 4 Après l installation la prise électrique doit rester accessible pendant l utilisation 5 Cette unité doit être mise au rebut si le cordon électrique est endommagé 6 Observez et adhérez à toutes les Normes Nationales pour Installations Electriques INSTRUCCIONES ADICIONALES PARA INSTALACION 1 Todas las bombas Clase II situadas en la Zona 1 de las áreas de la pisc...

Страница 13: ...uction Discharge Disassembled view of nut and ferrule Suction Line Solution Tank Shut Off Valve Discharge Line Grounded Power Outlet Grounded Fault Circuit Interrupter GFCI Direction of water flow Disassembled View of Injection Check Valve 26 80 psi Flow direction of solution Injection Check Valve ...

Страница 14: ... tank can result in debris pickup leading to clogged injectors and possible tube failure 2 Make connections by sliding the line s through connecting nut and ferrule and finger tighten to the corresponding tube fittings 3 Finger tighten nut to the threaded tube fitting while holding the tube fitting Over tightening the ferrule and nut with a wrench may result in damaged fittings crushed ferrules an...

Страница 15: ...trainer push approximately 3 5 of suction line through the cap on the strainer body Pull tubing to make sure it is secure 3 Suspend slightly above tank bottom to reduce the chance of sediment pickup DO NOT mix additives in the solution container Follow recommended mixing procedures according to the manufacturer DO NOT operate pump unless additive is completely in solution Turn pump off when replen...

Страница 16: ... beyond all pumps and filters or as determined by the application 2 A 1 4 or 1 2 Female NPT FNPT connection is required for installing the injection fitting If there is no FNPT fitting available provide one by either tapping the pipe or installing FNPT pipe tee fitting 3 Wrap the Male NPT MNPT end of injection fitting with 2 or 3 turns of threading tape If necessary trim the injection fitting quil...

Страница 17: ...necting nut to fitting 5 Turn pump on and re pressurize system Observe flow as actuated by system and check all connections for leaks 6 After suitable amount of dosing time perform tests for desired readings e g pH or ppm If necessary fine tune dosing levels by rotating potentiometer or by adjusting solution strength The injection point and fitting require periodic maintenance to clean any deposit...

Страница 18: ...lty Check supply voltage circuit DC motor is damaged Replace drive assembly Power cord is damaged Replace drive assembly Drive assembly runs Worn or damaged gears Replace gears as needed output shaft does not Phenolic gear is stripping Gear posts worn Replace gear posts and phenolic gear Rusted helical gear Buff off helical gear and replace phenolic gear Insufficient lubrication Replace phenolic g...

Страница 19: ... of the weighted strainer bottom of strainer cut bottom of suction tubing at an angle Pump cover not secured properly Ensure that pump cover is properly latched Low pump output Pump tube is worn Replace pump tube pump head rotates Rollers worn or broken Install new roller assembly Injection point is restricted Inspect and clean injection point Incorrect tube size Replace tube with correct size Hig...

Страница 20: ...si 5 5 bar Tube is twisted Replace pump tube and ferrules Tube not centered Replace pump tube and ferrules Tube life is shortened Incompatibility with fluid Check compatibility Mineral deposits at injection point Remove deposits replace pump tube and ferrules Sediment blockage at injection fitting Maintain suction line 2 3 above bottom of tank Seized rollers caused abrasion on tube Clean roller as...

Страница 21: ...ent damage to pump and or spillage PINCH POINT HAZARD Use extreme caution when replacing pump tube Be careful of your fingers and DO NOT place fingers near rollers HAZARDOUS PRESSURE EXPOSURE Use caution and bleed off all resident system pressure prior to attempting service or installation Use caution when disconnecting discharge tubing from pump Discharge may be under pressure Tubing may contain ...

Страница 22: ...e pump 2 Remove the locking screw on the latch CE models only Slide the vertical tab 180 degrees from left to right to unlock the cover latch Illustration A 3 To slide cover off push up on the raised edge Illustration B 4 Release the fittings from the slots to remove the tube Illustration C 5 Remove roller assembly 6 Use non citrus all purpose cleaner to clean residue from pump head housing roller...

Страница 23: ...on D 2 Align tube housing cover with track and slide over tube until fully closed Illustration E 3 Plug the pump in 4 Run the pump at full speed for one minute to relax the tube 5 To lock cover in place press down on the cover while turning the vertical tab 180 degrees from right to left Install the Phillips head locking screw CE models only Illustration F 6 Run pump at full speed for one minute t...

Страница 24: ...nored This is the safety alert symbol When displayed in this manual or on the equipment look for one of the following signal words alerting you to the potential for personal injury or property damage HAZARDOUS PRESSURE CHEMICAL EXPOSURE Use caution and bleed off all resident system pressure prior to attempting service or installation Use caution when disconnecting discharge line from pump Discharg...

Страница 25: ...should remain attached to the pipe Remove duckbill from check valve body and replace if deteriorated or swollen replace duckbill with every tube change If clogged clean or replace yearly replacement recommended Examine O ring in the injection fitting and replace if deteriorated or damaged 4 Insert a 2 Phillips head screwdriver through injection fitting into the pipe to locate or break up accumulat...

Страница 26: ...e injection fitting approximately 3 4 1 until it stops Pump 80 psi maximum includes Injection Check Valve Reassemble the injection check valve in reverse order Replace ferrule and reinstall the discharge line to the injection check valve approximately 3 4 until it stops 6 Tighten the connection nut finger tight 7 Enable the water pump electrical supply and pressurize the water system 8 Put the met...

Страница 27: ...27 USA and Canada 800 683 2378 International 904 641 1666 Econ LD EXPLODED VIEW White Roller Assembly Cover Screw Drive Assembly Drive Assembly Pad Gear Kit Pump Tube Pump Head Cover ...

Страница 28: ...ear Kit EC310 KIT includes spacers screws AquaShield Drive Assembly Pad EC302 EA White Roller Assembly EC350 EA Pump Tube ferrules 1 4 EC30__ 2 2 PK select M or F for __ Pump Head Cover EC355 EA Mounting Kit EC303 KIT for wall mount or Stenner tank Stand EC304 EA for horizontal display or wall mount ...

Страница 29: ...29 USA and Canada 800 683 2378 International 904 641 1666 Econ LD MOUNTING TEMPLATE ...

Страница 30: ...lorida 32246 USA Phone 904 641 1666 US Toll Free 800 683 2378 Fax 904 642 1012 sales stenner com www stenner com Hours of Operation EST Mon Thu 7 30 am 5 30 pm Fri 7 00 am 5 30 pm Assembled in the USA Stenner Pump Company All Rights Reserved IMELD 031017 ...

Страница 31: ...41 1666 Línea gratuita en EE UU 1 800 683 2378 Fax 1 904 642 1012 sales stenner com www stenner com Horario de atención GMT 05 00 Costa este USA Lunes a jueves de 7 30 a m a 5 30 p m Viernes de 7 00 a m a 5 30 p m Ensamblado en EE UU Stenner Pump Company Derechos Reservados IMELD 031017 ...

Отзывы: