Page
13
Molnar 4 Post Hoist
SM4
X
0
Maintenance
Checks
Check Daily
•
Check
lock assemblies
to see that
they
function properly.
Check Monthly
•
Safety mechanism operation.
•
Condition of
pulleys and
pins.
•
Condition of
cables
.
•
Overall cleanliness.
Check Six Monthly
•
Oil leaks from the cylinder, pipe joints and anchor bolts
•
Cables
•
Cables
must be inspected by a
COMPETENT
person.
(Cables are considered a wear and tear
item and not subject to the regular 3 year warranty)
•
Inspect for wear, rust and broken wires.
Yearly
Service and safety inspection on hoist
shall
be performed by a competent person. This inspection
must be recored. If the 12 monthly service and safety inspection is not performed, the warranty is
null and void.
NOTE:
10
Year service must include removal of pulleys to inspect and clean bushes.
2 Yearly
Hydraulic oil should be replaced (irrespective of the amount of use to which the hoist is subjected).
Fill Hydraulic Tanks to oil level line with ISO 46 Hydraulic oil. (i.e. Castrol Hyspin AWH 46)
Lubrication
Pulleys
All pulleys shall be greased
monthly
. This includes the four transverse beam pulleys as well as the
front and rear pairs of pulleys under the platform. (Pulley pins are supplied with grease nipples
for easy greasing
, i.e. Castrol Spheerol LMM Grease
).
Cables
Cables shall be lubricated
at least every six months
. This extends the life of the cable and helps
protect against rust. (i.e. Lanotec Heavy Duty Lanolin Spray)