PP500 LED lighting controllers - User Manual
9
Front panel configuration
Using the front panel keypad, you can set the configuration for each
channel and set a keylock code so unauthorised users cannot change any
settings.
9.1
Startup
On power up, the PP500 displays
br
for five seconds followed by
8.8.8.
to
show that the display is working, then
PP5
and
00
or
00F
, followed by the
firmware version (for example
029
). The controller is then ready for
operation. To show the unit is operating normally, the LED display shows a
pattern of alternating lines.
9.2
Setting the light rating
The Autosense feature detects the presence of a light and prompts you to
set the rating as follows:
When the PP500 detects a light connected to
channel 1 for the first time, Sn1 is displayed. (A
light connected to channel 2 will display Sn2).
When the Cu1 prompt is displayed, press the
SEL button to set the current rating of the light.
Use the
p
and
q
buttons to select the rating of
the light in Amps. The current is adjustable in
steps of 10mA. Press the SEL button when you
have set the current.
—
22
—
PP500 LED lighting controllers - User Manual
The PP500 displays a pattern of alternating
horizontal bars when the light is operating
normally. If you power cycle the controller, it will
resume with the same settings.
Other displays are shown for channel 2
connected, and channels 1 and 2 connected.
If an error occurs (if the light is disconnected for
example), the PP500 displays
OP
. Press the
SEL
button to cancel this.
9.3
Setting up continuous output
Press the
SEL
button for 1 second and follow the steps below:
CH1
is displayed. Use the
p
and
q
buttons to
select
CH2
if you wish to set up channel 2.
Press the
SEL
button.
—
23
—