This thermostat is designed to control baseboard and convector heaters. It may be added (included)
in a Z-Wave network.
This thermostat is
NOT
compatible with the following installations
• Inductive load
• Central Heating System
• Fan-forced heater (unit containing motor and fan)
• Heating load outside the specified ratings (Refer to section ‘’Technical Specifications’’)
Parts supplied
• one (1) thermostat;
• one (1) wall mounting plate located at the back of the thermostat;
• two (2) mounting screws;
• two (2) solderless connectors suitable for copper wires
Selection of the thermostat location
The thermostat must be mounted to a connection box on a wall facing the heating unit, at around 1.5 m
(5 feet) above the floor level, on a section of the wall exempt from pipes or air ducts.
Do not install the thermostat in a location where temperature measurements could be altered. For
example:
• close to a window, on an external wall, or close to a door leading outside;
• exposed directly to the light or heat of the sun, a lamp, a fireplace or any other heat source;
• close or in front of an air outlet;
• close to concealed ducts or a chimney; and
• in a location with poor air flow (e.g. behind a door), or with frequent air drafts (e.g. head of stairs).