040D05A_INS1215
12
Factory Reset
The thermostat may be manually reset to its factory state.
When this is performed, all parameters are reset to their default values and the thermostat is
removed (excluded) from the Z-Wave network.
To reset the thermostat to its default state:
- Enter the advanced settings
- Enter the °STELPRO menu (menu 6)
- Navigate to the “def” screen using the UP or DOWN buttons.
- Enter the “def” menu by pressing the UP and DOWN buttons for less than 3 seconds
- Select “yes” and confirm the selection by pressing the UP and DOWN buttons for less than 3 seconds.
If the thermostat was added (included) in a Z-wave network, it will send a ‘’device reset locally’’
notification.
The thermostat will then reset itself.
Please use this procedure only when the network primary controller is missing or otherwise
inoperable.
Outdoor Temperature (
)
When connected to a Z-Wave network, the thermostat may display the outdoor temperature
provided by an external sensor.
When available, the outdoor temperature is displayed instead of the set point, providing that the
outdoor temperature display setting is set to on.
If no temperature is received within a 4 hours timeframe, the outdoor temperature will disappear
and the set point will be displayed.
In order to display the outdoor temperature, an external sensor needs to be part of the Z-Wave
network. It may be a physical sensor or a weather station app.
Refer to your Z-Wave hub controller instructions manual to find how to associate both devices. On
some Z-Wave hub controllers, an app may be used to provide the outdoor temperature.