INS_CUST UL REV E
Page 18
IMPORTANT FRAMING NOTES:
THE FIREPLACE IS NOT LOAD-BEARING
FRAMING SHOULD BE BUILT AFTER THE FIREPLACE IS INSTALLED OR EXTRA CLEARANCE MUST BE PLANNED FOR AT THE INTAKE
COLLAR AND FOR THE THICKNESS OF MATERIALS USED.
FRAMING DIMENSIONS ASSUMING 1/2" [13] DRYWALL AND NON-COMBUSTIBLE BOARD USED.
THESE DIMENSIONS REPRESENT THE FRAMING DIMENSIONS FOR COMBUSTIBLE MATERIAL.
NON-COMBUSTIBLE FRAMING AND FINISHING MATERIALS MAY BE USED WITHIN THESE DIMENSIONS RIGHT UP TO THE UNIT.
NO COMBUSTIBLE MATERIAL WITHIN 6" [152] OF THE TOP OF THE FIREPLACE.
NO COMBUSTIBLE MATERIAL WITHIN 1" [25] OF THE SIDES, BACK AND FRONT OF THE FIREPLACE.
COMBUSTIBLE MATERIAL SHALL NOT BE PLACED DIRECTLY ON THE FACE OF THE FIREPLACE, TOP AND SIDES.
SEE SECTION 5 (NON-COMBUSTIBLE ZONE) AND SECTION 10 (FINISHING) FOR DETAILS REGARDING 1/2" [25] STANDOFFS.
STEEL SURFACE MAY BE COVERED WITH NON-COMBUSTIBLE FINISHING MATERIAL.
1" CLEARANCE TO THE B-VENT MUST BE MAINTAINED.
5 - FRAMING
NOTE: Framing dimensions should allow for wall covering thickness and fireplace facing materials. When using a hearth,
adjust rough opening size as necessary to maintain at least minimum clearance requirements.
If masonry is to be used (optional), prepare the necessary foundation for the masonry load. When masonry construction is being used, a lintel must be
used over top of fireplace to support the added weight. Build hearth to desired size and height. If a hearth extension is desired, combustible material
may be used.
CAUTION: Install fireplace on metal, concrete or hard wood surface extending the full width and depth of fireplace.
CAUTION: Vent cap location must be in compliance with guidelines in
Section 8 (Venting)
of this manual.
NOTE:
DO NOT
FOUR SIDEDCE ANY OF THE BLACK PAINTED SURFACES WITH SCREWS, RIVETS, ETC.
THIS INCLUDES THE 3" [76] BLACK TOP AND BOTTOM GLASS TRIM AND ANY PAINTED SIDES ADJACENT TO THE GLASS.
NOTE: REFER TO DIMENSIONS SECTION FOR ALLOWABLE FINISHING DIMENSIONS REQUIRED TO FIT THE GLASS
PANELS INTO THE FIREPLACE. FINISHING MATERIALS MUST NOT OVERLAP THE DIMENSIONS HIGHLIGHTED IN GREEN IN
SECTION 2 (DIMENSIONS)
. NEVER COVER THE GLASS WITH FINISHING MATERIALS.