![Stel TIG mP 273H DC Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/stel/tig-mp-273h-dc/tig-mp-273h-dc_instruction-manual_1371523012.webp)
6998400030
12
FRONT PANEL DESCRIPTION
1
Tig spot LED mode
2
MMA LED mode
3
Tig 2T LED mode
4
Tig 4T LED mode
5
Select mode button
6
Dual-Tig™ LED mode
7
TIG HF LED mode
8
TIG HF mode button
9
Pulse Mode LED
10
Pulse Mode button
11
Encoder regulation Current/Functions
12
Tig Function button
13
Select Job button
14
Post Gas LED
15
Base Current LED
16
Slope Down LED
17
Slope Up LED
18
Welding Current LED
19
Base Current LED
20
Pre Gas LED
21
Amps Display
22
Volt Display
23
Over temperature LED
24
Welding enabled LED
25
Machine live LED
SUB MENU
- PULSE DUTY AND PULSE
FREQUENCY ADJUSTMENTS
1) Select the Pulse mode with button
10,
the LED
9
illuminates
.
2) With the encoder
11
adjust the value of Duty
from 10% to 90%.
3) With the encoder
11
adjust the value of
Frequency from 0,4-999Hz.
- PARAMETERS STORING
The operator can store all selected parameters in
the 60 free memory programs available. These
programs can be easily recalled at any time.
PARAMETER STORING
1) Press buttons
12
and
13
together
2) The Display will show the wording "PRG"
3) With the Encoder
11
select a program number
from 0 to 59 (the 60 is a factory default).
4) Press and hold for 5 seconds the button
5
to
store the parameters.
RECALL THE PARAMETER
1) Press buttons
12
and
13
together
2) The Display will show the wording "PRG"
3) With the Encoder
11
select the number of
program stored.
4) Press and hold for 5 seconds the button
8
(Set
Prg) to recall the parameter.
Amps
t
Frequency
Duty
Содержание TIG mP 273H DC
Страница 15: ...6998400030 15 EXPLODED VIEW...
Страница 17: ...6998400030 17 WIRING DIAGRAM...
Страница 19: ...6998400030 19 WELDING TABLE STAINLESS STEEL...
Страница 20: ...6998400030 20 Info www stelgroup it tel 39 0444 639525...