Dimensions:
(H x W x D) 113 x 78 x 73 mm
Output:
600 watts max. (resistive load, e.g. filament bulb)
500 watts max. (uncorrected, inductive,
cos ö = 0.5, e.g. fluorescent tubes)
500 watts max. (series corrected)
500 watts max. (shunt corrected,
at C = 45.6 µF)
500 watts max. (electronic ballasts, capacitive e.g.
low-energy lamps, 8 each max.)
Connection:
230 – 240 V, 50 Hz
terminal block suitable for following supply leads:
3-core Ø 1.5 or 2.5 mm
2
or 5-core Ø 1.5 mm
2
Angle of coverage:
160° with sneak-by guard
Pivoting range:
40° horizontal, 70° vertical
Reach:
12 m max.
Light threshold:
2 – 2000 lux
Time setting:
8 sec. – 35 min. (factory setting: 10 sec.)
Light threshold:
2 – 2000 lux (factory setting: 2000 lux)
Enclosure:
IP 54
Technical specifications
without power
W
Fuse blown, not
switched ‘ON’
W
Short circuit
W
Renew fuse, switch on
mains power switch,
check wiring with
voltage tester
W
Check connections
does not switch ‘ON’
W
T wilight setting in
nighttime mode during
daytime operation
W
Bulb blown
W
Mains switch ‘OFF’
W
Fuse blown
W
Detection zone not
properly targeted
W
Readjust
W
Replace bulb
W
Switch ‘ON’
W
Renew fuse, check
connection if
necessary
W
Re-adjust
Troubleshooting
Malfunction
Cause
Remedy
16
17
Remedy
Does not switch ‘OFF’
W
Continued movement
in detection zone
W
Light is in detection
zone and keeps switch-
ing on as a result of
temperature change
W
Set to continuous
operation by indoor
series switch
W
Check detection zone
and re-adjust if neces-
sary or fit shrouds
W
Readjust zone
W
Set series switch to
automatic mode
Keeps switching ‘ON’/’OFF’
W
Light is in detection
zone
W
Animals moving in
detection zone
W
Change zone,
increase distance,
reduce output
W
Tilt sensor higher or
apply specific shrouds,
adjust detection zone
or fit shrouds
Switches ‘ON’ when it
should not
W
Wind is moving trees
and bushes in the de-
tection zone
W
Cars in the street are
being detected
W
Sudden temperature
changes due to wea-
ther (wind, rain, snow)
or air expelled from
fans or open windows
W
Adjust detection zone
or fit shrouds
W
Change detection
zone, tilt sensor down
W
Adjust detection zone
or change site of in-
stallation
Reach modification
W
Change in ambient
temperatures
W
When it is cold,
shorten reach by
tilting sensor down
W
When it is hot, tilt
sensor up
Cause
Malfunction
Содержание StudioLine IS 2160