Technical Specifications

Electrical installation/Automatic mode

In selecting the wiring leads, it is 
important to meet the wiring 
regulations laid down in VDE 0100 
(see Safety warnings on page 19). 
The following applies to wiring 
presence detectors: According to 

section 6 of VDE 0100 520, a multi-
ple-core lead containing both the 
mains voltage leads and the con-
trol leads (e.g. NYM 5 x 1.52) may 
be used for wiring between the 
sensor and electronic ballast. The 

mains connection lead must be no 
greater than 10 mm in diameter. 
The clamping range of the mains 
terminal is designed for a maxi-
mum of 2 x 1.5 mm

2

 or 1 x 2.5 mm

2

.

P S N

L L'

L

N

P

L

N

COM1

P S N

L L'

L

N

L

N

1-10V

1-10V

+ –

max. 100 mA

DIM

DIM

COM 1

COM 2

COM 1 AP

GB

Dimensions
(w x h x d)

HF 360

 

 

120 x 120 x 56 mm 

Dual HF

120 x 120 x 76 mm

Supply voltage

230 – 240 V, 50 Hz / 60 Hz

Capacity, 

switching output 1

(COM 1/COM 2)

Relay 230 V
Resistive load 2000 W max. (cos 

ϕ

 = 1)

1000 VA max. (cos 

ϕ 

= 0,5)

Electronic ballast:
(COM 1/COM 1 AP/
COM 2/DIM)

Max. 'ON' current 800 A/200 μs
30 x (1 x 18 W), 25 x (2 x 18 W)
25 x (1 x 36 W), 15 x (2 x 36 W)
20 x (1 x 58 W), 10 x (2 x 58 W)
Pay attention to specific 'ON' currents of electronic ballasts! 
A relay or contactor must be provided on line side for higher switching 
capacities.

Capacity, 

switching output 2

(COM 2 only) (HF 360 only)

Presence

230 W max. / 230 V
1A max. (cos 

ϕ

 = 1) for HVAC (heating/ventilation/air-conditioning)

Application

indoors

Mounting height
(mounted to ceiling)

2.5 m – 3.5 m ceiling height

Detection angle

HF 360

 

 

360° with 140° aperture angle  
also through glass, wood and 
stud walls. 1 or 2 detection direc-
tions can be masked out for ad-
justment to the room situation.

Dual HF

see diagrams on p. 21
also through glass, wood and stud 
walls

Reach

HF 360

8 m max. all round, 
electronically and infinitely 
variable

Dual HF

10 x 3 m max. in each direction, 
electronically and infinitely 
adjustable

Switching output 1

 

Time setting

30 sec. – 30 min., pulse mode (approx. 2 sec.)
IQ mode (automatic adjustment to use profile)

Switching output 2

 

Time setting

(HF 360 only)

COM2 only for HVAC

0 sec. – 10 min. switch-'ON' delay
1 min. – 2 h stay-'ON' time
Automatic room surveillance

DIM:

Time setting

30 sec. - 30 min.
IQ mode (automatic adjustment to use profile)

Control output

1 – 10 V / max. of 50 electronic ballasts, max. of 100 mA

Sensor system

High-frequency 5.8 GHz, transmission power < 1mW

Function setting by 
DIP switches

DIP 1 Normal / test mode
DIP 2 Semi- / fully automatic mode
DIP 3 Button / switch mode
DIP 4 'ON' button / 'ON'-'OFF' button
DIP 5 Constant-lighting control 'ON'-'OFF' (DIM)

Parallel connections

Master/slave
Master/master

User-friendly setting capability Teach-in (with optional remote control RC3)
Light-level setting

10 – 1000 lux, ∞ / daylight
DIM 100 – 1000 lux

IP rating

IP 20 (IP 54 with surface-mounted box)

Safety class

II

Temperature range

0° to +40° C

Housing

UV-resistant, paintable

PC PRO HF360_DualHF_Osteuropa.indd   22-23

PC PRO HF360_DualHF_Osteuropa.indd   22-23

11.09.13   10:36

11.09.13   10:36

Содержание DUAL HF COM 1

Страница 1: ...47 22725001 post vilan no GR PANOS Lingonis Sons O E Aristofanous 8 Str GR 10554 Athens Tel 30 210 3212021 Fax 30 210 3218630 lygonis otenet gr PL L Sp ka z ograniczon odpowiedzialno ci sp k Byk w ul...

Страница 2: ...MAN ON ON OFF 4 NORM TEST AUTO MAN ON ON OFF LUX 1 6 5 3 2 4 min 30 sec 30 IQ 1 min 15 5 2 9 min 30 sec 30 IQ 1 min 15 5 2 6 5 LUX 1 6 5 3 2 4 min max min max HF 360 COM 1 COM 1 AP DUAL HF COM 1 COM 1...

Страница 3: ...2 30 sec min t off min t on 5 10 30 30 sec 30 IQ 1 min 15 5 2 min max min max min max 9 6 5 0 sec 30 ON 1 min 15 5 2 15 LUX 1 6 5 3 2 4 30 sec 30 IQ 1 min 15 5 2 NORM TEST AUTO MAN ON ON OFF LUX 1 6...

Страница 4: ...ter L N OUT IN Treppen haus automat P S N L L P S N L L N L Master Slave P S N L L Slave 14 1 14 1 14 2 14 3 14 4 cable length 50 m PC PRO HF360_DualHF_Osteuropa indd 6 7 PC PRO HF360_DualHF_Osteuropa...

Страница 5: ...1 10V L N L Master Slave N L 1 10V 1 10V P S N L 1 10V L P S N L 1 10V L 14 5 HF 360 cable length 50 m PC PRO HF360_DualHF_Osteuropa indd 8 9 PC PRO HF360_DualHF_Osteuropa indd 8 9 11 09 13 10 36 11...

Страница 6: ...ster to make sure the wiring is off circuit Installing the sensor involves work on the mains power supply This work must there fore be carried out profes sionally in accordance with the applicable nat...

Страница 7: ...air conditioning Application indoors Mounting height mounted to ceiling 2 5 m 3 5 m ceiling height Detection angle HF 360 360 with 140 aperture angle also through glass wood and stud walls 1 or 2 dete...

Страница 8: ...s priority over all other settings on the presence detector and serves the purpose of checking for proper working order as well for testing the de tection zone Irrespective of am bient light level the...

Страница 9: ...clockwise Room surveillance Turned fully anti clockwise 0 sec OFF Turning the potentiometer to the Surveillance setting reduces the sensitivity of the Presence switching output The contact only closes...

Страница 10: ...ts not covered by the warranty or occurring after the warranty expires Troubleshooting Light does not switch ON Light does not switch OFF Sensor switches OFF in spite of persons being present Sensor d...

Отзывы: