– 13 –
Important:
Incorrectly wired connections will produce a short
circuit later on in the product or your fuse box. In
this case, you must identify the individual conduc-
tors once again and re-connect them. A mains
power switch for turning the unit ON and OFF may
of course be installed in the mains supply lead.
Note:
The light source in this light must only replaced by
the manufacturer or a service engineer authorised
by the manufacturer or by a similarly qualified
person.
Connecting the mains power supply lead
(Fig. 5.6)
L 240 S, L 220 S wiring diagram
(Fig. 4.2)
L 240 S, L 220 S wiring diagram
(Fig. 4.3)
5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, giving
consideration to sensor reach and mounting
height
(Fig. 5.1)
.
Mounting procedure
(Based on the example of L 220)
• Switch OFF power supply
(Fig. 4.1)
.
• Detach light housing from the wall mount, paying
attention to the position of the sensor
.
• Mark drill holes
.
• Drill holes and insert wall plugs (concealed power
supply cable
(Fig. 5.4)
.
• Drill holes and insert wall plugs (with spacers for
surface power supply cable
(Fig. 5.5)
.
• Connect conductors
.
• Connect plug-in connectors
.
• Fit light enclosure
(A)
onto wall mount
(C)
. Pay
attention to plug-in connections as well as the
position of the sensor
.
• Screw light enclosure into place
.
• Switch ON power supply
.
• Make settings (S only)
➔
"6. Functions"
.
6. Functions
The sensor-switched light can be put into service
after mounting the light enclosure and connecting
to the mains power supply.
Factory settings
(S only)
Twilight setting: daylight operation 2000 lux
Time setting: 8 s
Twilight setting / response threshold
(S only)
–
The sensor's response threshold can be infinitely
varied from 2–2000 lux.
–
Control dial set to = daylight operation,
approx. 2000 lux.
–
Control dial set to = night-time operation,
approx. 2 lux.
Time setting
(S only)
(Fig. 6.1)
–
Light ON duration can be infinitely varied from
8 s - 35 min
–
It is recommended that the shortest time be
selected for setting the detection zone.
–
Control dial, shortest time = approx. 8 s
–
Control dial, longest time = approx. 35 min
Adjusting the detection zone / reach setting
(S only)
–
Depending on the mounting height, the detection
zone setting can be optimised to suit require-
ments. The shroud foil can be used for masking
out any number of lens segments to limit reach
as required, e.g. to mask out paths or neigh-
bouring property
(Fig. 6.2)
.
–
Reach can be adjusted from 2-10 m by tilting
the sensor
(D)
through 90°
(Fig. 6.3).
House numbers
• Affix the house street number using the stickers
provided
(Fig. 6.4)
.
7. Maintenance / care
Warning of hazards from electricity!
Contact between water and live parts can result in
an electric shock, burns or death.
• Only clean device in a dry state.
Risk of damage to property!
Using the wrong cleaning product can damage the
light.
GB
Содержание 010454
Страница 3: ...3 3 5 L 220 S 185 5 153 32 5 57 246 3 6 L 220 185 5 153 32 5 57 246 3 7 L 240 S 3 8 L 220 S 3 9 L 220...
Страница 5: ...5 5 4 5 5 5 6 5 7 5 8 5 9...
Страница 6: ...6 5 10 6 I O 6 1 L 240 S L 220 S 6 2 L 240 S L 220 S 6 3 L 240 S L 220 S 6 4 L 240 S L 220 S...
Страница 64: ...64 7 8 9 STEINEL STEINEL 36 1 3 5 GR...
Страница 66: ...66 11 S S S S S...
Страница 124: ...124 S 6 2 D 90 2 10 6 3 6 4 7 8 9 Steinel STEINEL 36 1 3 RU 5...
Страница 126: ...126 11 S S S S S...
Страница 129: ...129 7 8 9 Steinel STEINEL 36 1 3 BG 5 BG...
Страница 131: ...131 11 S S S S S BG...
Страница 135: ...135 11 S S S S S S 2 2000 Lux IP 44 II IK 07 20 50 C www steinel de D CN...