8 Troubleshooting
Malfunction
Cause
Solution
Pressure gauge has reading
over 1 bar.
Dirty filter bed
Backwash the Filter (Valve Position
Nr. 2)
Pressure is too low
Suction line contaminated with dirt.
Pump gets too little water.
Clean suction line
Air in the pump
Poor seal on the suction side
Tighten hose clamps and connect-
ing fittings.
Water flows into the drainpipe
Dirt around the seal of the Central
Valve
Unscrew the Central Valve from fil-
ter cover and clean the seal
Leaking filter
Seal Defective
Check the seal, replace if needed
Pump does not run
Not plugged in
Check the socket and power cord
G.F.C.I/ or main circuit breaker tripped
Switch on the breaker (if it is imme-
diately tripped again, there is a de-
fect in pump or controls)
Pump motor defective
Replace the entire pump
Filter System is switched-off by a time
switch or a filter control system
Check settings
Sand in Pool
If the sand is newly replaced, the un-
dersized grains are still present.
Backwash several times until the
backwash water is clear. (Valve
Position Nr. 2)
Separation wall in filter is im-properly
installed.
Check the separation wall for prop-
er positioning.
Filter bottom strainer is damaged.
Replace the filter bottom strainer.
Repairs on the pump should only be performed by trained and qualified, professional technicians.
9 Service
Processing
For technical information, missing parts or in the case of a complaint, please contact our customer service:
Important note:
On the pump label of your filter pump is a serial number (B/...) indicated and on the tank cover is a lot
number shown (read from above on handle), please provide this data in the case of a complaint.
Steinbach VertriebsgmbH
Aistingerstrasse 2
4311 Schwertberg
Tel. Austria: (0820) 200 100 100 (0,145€ per minute from all networks)
Tel. Germany: (0180) 5 405 100 100 (0,14€ per minute from landline, mobile radio max. 0,42€ per minute)
e-mail: [email protected]
www.steinbach.at
ADVICE
Содержание Speedclean Eco 30
Страница 17: ......