22
STEIN300_Hubzentriereinrichtung_HZEV_03_GB.DOC_D / 02.2020
7 Clean the surfaces with a soft, lint free cloth, lightly dampened with cleaning fluid.
Environmental protection
Dispose of waste material and used cleaning cloths in an environmentally responsible
way.
9.2
Inspection
Interval
Component
Inspection
criterion
Solution
Annually
Securing screw between
the HZEV and the belt
element
Tightly fastened
Tighten loose screws -
see chapter 5
Inductive proximity
switch
Tightly fastened
Tightly fasten inductive
proximity switches
Compressed air hoses
Stable connections Re-tighten loose con-
nections
Tightly fit push connect-
ors -
see chapter 5
Entire HZEV
Play, functional
accuracy
Re-tighten loose screw
connections
Accurately re-position
inductive proximity
switches
Signs of wear
Replace worn retaining
bolts
9.3
Maintenance
The lift centring devices with extended stroke require no maintenance.