If the Comfort Plus Hydronic is installed in an area where radiant heat coming from the system is undesired or
where room temperatures may reach 85

°

 Fahrenheit or greater, it is strongly recommended to install a Static Heat

Recovery unit or Air Handler. Refer to page 2.01 for information on these options.

In addition to the physical space requirements, the weight of the Comfort Plus Hydronic must be taken into consid-
eration when selecting the installation surface.  A level concrete floor is the best installation surface, but most well
supported surfaces are acceptable.  If unsure of floor load capacity, consult a building contractor or architect.

Special  requirements  need  to  be  considered  if  placing  the  system  in  a  garage  or  other  area
where  combustible  vapors  may  be  present.  Consult  local,  state,  and  national  codes  and  regula-
tions  to  ensure  proper  installation.  An  18"  stand  (Order  Item  #1301585)  is  available  to  elevate
the  system.

INITIAL  SET-UP

Step  1

Remove the Information Package from the outside of
the shipping box and unpackage the Comfort Plus
Hydronic heating system.

Step  2

Move the heating system into its installation location.
The Comfort Plus Hydronic is capable of fitting through
a 30" doorway (minimum) without disassembling.  If it
is necessary to disassemble the system, refer to the
disassembly instructions (Page A.11) in this manual.

Step  3

Once in place, adjust the leveling legs on the bottom of
the system as necessary to prevent rocking.  If not
placed properly the system may bend or twist during the
brick loading process, making element and brick core
temperature sensor installation difficult.

Step  4

Remove the painted front panel of the brick storage
cabinet by removing the sheet metal screws along the
top, bottom, and sides of the panel.  Detach by pulling
the bottom of the panel forward and down.

Step  5

Locate the element wiring harnesses and brick core temperature sensor(s) behind the front panel and
disconnect them from their shipping position.  Carefully position them to avoid damage during brick
loading.

Models  5130  and  5140  have  two  brick  core  temperature  sensors.

Step  6

Remove the galvanized front panel and set it aside.

Step  7

Carefully lift the two insulation blankets, one at a time starting at the bottom, and drape them over the
top of the system.

Use  face  mask,  gloves,  and  long  sleeved  garments  when  handling  insulation  materi-
als  in  compliance  with  generally  accepted  safety  practices.

Step  8

Remove the front air channel by pulling out at the top.

Step  9

Remove the heating elements from inside the brick core cavity.

To ensure proper operation, read and
follow installation instructions carefully.

DO NOT install the Comfort Plus
Hydronic system on its shipping
pallet.

DO NOT extend the leveling legs
more than one inch.

DO use and follow generally
accepted safety practices when
handling  insulation  material.

DO have equipment installed by a
qualified technician  in compliance
with all applicable codes and
regulations.

IMPORTANT

In

st

al

la

ti

on

Installation 

 

3.03

Comfort  Plus  Hydronic

Содержание Comfort Plus Hydronic 5120

Страница 1: ...V11 OWNER S AND INSTALLER S MANUAL Manufactured in North America for COMFORT PLUS HYDRONIC 5100 SERIES Models 5120 5130 5140 Applicable to Software Version 140 159 ...

Страница 2: ... Steffes Corporation has used its best judgement based upon information available but disclaims any responsibility or liability for any errors or miscalculations contained herein or any revisions hereof or which result in whole or in part from the use of this manual or any revisions hereof After the heating system is installed Steffes disclaims any responsibility or liability for mold mildew growt...

Страница 3: ...ect the pressure relief valve in a vertical upright position with the supplied fittings DO NOT modify this assembly DO NOT cap plug or otherwise obstruct the outlet of the pres sure relief valve Risk of fire Can cause injury or death Viola tion of the clearance requirements can cause improper operation of the equipment Main tain the placement and clearance require ments specified Risk of personal ...

Страница 4: ...annel Installation 3 04 3 05 Brick Core Temperature Sensor Installation 3 05 LineVoltageElectricalConnections 3 06 3 07 LowVoltageElectricalConnections PeakControl 3 07 3 08 Outdoor Temperature Sensor 3 08 3 09 RoomThermostat 3 09 3 10 Air Conditioner Heat Pump Interface 3 10 Pressure ReliefValve Installation 3 11 Plumbing 3 11 3 13 AuxiliaryLoadControl 3 13 Configuration Menu 3 14 3 15 Installer ...

Страница 5: ...nent heating system during the construction phase may contaminate the duct system and or internal areas of the heating system This may cause poor indoor air quality issues and or improper system operation once the home is completed A suitable alternative heating system must be used during the construction phase SYSTEM START UP On start up of the Comfort Plus Hydronic system odors relating to first...

Страница 6: ...ress and release the up arrow to view this data Outdoor Temperature indicates current outdoor temperature Operating Mode and Outlet Water Temperature indicates the current operating mode followed by the outlet water temperature C Off Peak Charge Time P On Peak Control Time A Anticipated Peak Time Heat Call Status indicates the current heat call status as determined by the room thermostat s The fac...

Страница 7: ...charge level during the next off peak period It continues to charge during off peak hours until the system achieves full maximum core charge or until the override is cancelled Once full charge is achieved or the override is cancelled the system charges according to its standard configuration Initiating the Override Feature Step 1 Press and hold the M the up arrow and the down arrow buttons at the ...

Страница 8: ...peration and draining Incorporates isolation flanges for quick and easy servicing of the primary loop pump circulator Offers troubleshooting isolation between the heating system and secondary zones AIR HANDLER The Steffes air handler allows the 5100 series heating system to provide forced air heating or to be interfaced with other ducted heating and or cooling systems such as a heat pump or air co...

Страница 9: ... 130 CFM NOTE In applications using the Steffes Air Handler the static heat recovery unit would not be used If the area available to install the Comfort Plus Hydronic system is less than 100 square feet Steffes Corpora tion recommends installing a low voltage cooling thermostat connected between R and G on the 12 position terminal block to maintain a temperature less than 85 degrees Fahrenheit COM...

Страница 10: ... to Pages 3 04 3 05 PRESSURE RELIEF VALVE KIT 7 shipped behind the exchanger access panel Refer to Page 3 11 JUNCTION BOX shipped behind the exchanger access panel See Figure 9 Page 3 07 1 INFORMATION PACKAGE includesOwner sManualand WarrantyRegistrationCard adhered to outer side of shipping box shipped inside the brick core Refer to Pages 3 04 3 05 2 MODEL ELEMENTS 5120 8 5130 12 5140 16 HEATING ...

Страница 11: ...in an area with less than 400 square feet ventilation MUST be provided If the area available to install the system is less than 100 square feet consult the factory MINIMUM CLEARANCE REQUIREMENTS Back and Right Side 3 inches from combustible material Bottom 1 inch clearance Top 6 inches from combustible material Front 36 inches for ease in servicing Left Side 36 inches for ease in servicing 5100 SE...

Страница 12: ...tom of the system as necessary to prevent rocking If not placed properly the system may bend or twist during the brick loading process making element and brick core temperaturesensorinstallationdifficult Step 4 Remove the painted front panel of the brick storage cabinet by removing the sheet metal screws along the top bottom and sides of the panel Detach by pulling the bottom of the panel forward ...

Страница 13: ...ce MUST be installed in the front row Risk of fire Can cause personal injury or death DO NOT operate the Comfort Plus Hydronic system if damage to the insulation panels on the inner sides of the brick core occurs WARNING HEATING ELEMENT AND AIR CHANNEL INSTALLATION Step 1 After all brick are loaded insert the heating elements between the brick layers sliding them in until the element ends embed in...

Страница 14: ...Hydronic heating system Read and follow installation instruc tions carefully Step 2 Install the front air channel by placing the bottom in first with the air deflec tors arrow shaped pieces facing inward Refer to the Air Channel Placement Figure 6 and the Parts Diagram Page A 02 for proper placement and installation of the front air channel Step 3 Lower the insulation blankets back into position o...

Страница 15: ...he Comfort Plus Hydronic breakers Refer to the Line Voltage Wiring Diagrams Pages A 05 A 07 for more information on these connections To ensure proper operation and safety all line voltage circuits must be segre gated from low voltage wiring in the ComfortPlus Hydronic To reduce electro magnetic fields associated with electrical circuits and to avoid induced voltage on sensors and electronic devic...

Страница 16: ...ors rated at Wiring Diagram 240 208 Volt 5120 Line Voltage LOW VOLTAGE ELECTRICAL CONNECTIONS PEAK CONTROL Steffes ETS heating equipment may be controlled by the Power Company via a peak control signal This signal can be sent to the equipment using a Steffes Power Line Carrier control system low voltage wiring a Steffes Time Clock Module or linevoltage control In applicationsutilizingautomatic cha...

Страница 17: ... feature Refer to the instructions provided with the Time Clock Module for more informa tion on the installation and operation of this device LINE VOLTAGE PEAK CONTROL Line voltage control is also an option but is not the preferred method of control as it is usually more complex and expensive If line voltage control is utilized the controls circuit must be powered with an uninterrupted circuit An ...

Страница 18: ...utdoor sensor ONLY This low voltage cable MUST not enter any line voltage enclosure Unshielded Class II thermostat wire can be used as extension wire provided it is segre gated from any line voltage cabling LOW VOLTAGE ELECTRICAL CONNECTIONS ROOM THERMOSTAT A low voltage 24VAC room thermostat is required for room temperature control with the Comfort Plus Hy dronic system Steffes recommends using a...

Страница 19: ...c Heat Thermostat Zone Valve End Switch or Pump Control R W AIR CONDITIONER HEAT PUMP INTERFACE The Comfort Plus Hydronic system can be used in conjunction with an air conditioner or a heat pump Refer to the optional Air Handler Page 2 01 and the Low Voltage Connections for Heat Pump Application Diagram Figure 11 for more information on interfacing these systems with the Comfort Plus Hydronic If m...

Страница 20: ...his discharge line MUST be connected from the valve outlet with no intervening valve and directed downward to a safe point of discharge allow complete drainage of both the valve and the discharge line be independently supported and securely anchored to avoid applied stress on the valve be as short and straight as possible terminate freely to atmosphere where any discharge is clearly visible and is...

Страница 21: ...ommends a Grundfos UP15 42F single speed 115VAC pump for the primary pump Air Handler pump should NOT be a split phase pump Air Handler pump should NOT have any type of auxiliary control built into or onto the pump White Red Primary Loop Secondary Loop Primary Loop Pump Comfort Hydronic Exchanger This Valve Must Be Open During Normal Operation White Red FREEZE PROTECTION Risk of frozen pipes Can c...

Страница 22: ...sformer NOTE During off peak charge periods the contact is closed between COM and NC TYPICAL AUXILIARY LOAD CONTROL FIGURE 17 RP Y C R O G Y2 OS H W O2 SC DS Auxiliary Control Relay RELAY Peak Control Internal Output Relay COM AP P NO NC TYPICAL SYSTEM PLUMBING SHOWN WITH STEFFES AIR HANDLER FIGURE 16 It is the responsibility of the installer to prevent involuntary flow of water to the air handler...

Страница 23: ...ted to the desired values Step 7 Once configured use the down arrow to leave the Configuration Menu In most applications only a few if any configuration changes will be necessary Following is a description of the configurationsettingsandtheirfunction C000 Off Peak Method of Charge Control Sets the method of brick core charging to be used during off peak charge periods System is configured for auto...

Страница 24: ...nimum discharge air temperature the system targets during a Stage 1 heat call C011 and C012 configurations must be set for the hottest temperature zone in the installation C011 is the highest tempera ture the system will target and C012 is the lowest temperature the system will target during a heat call Outdoor reset is done using these two temperatures See graph C011 Maximum Outlet Water Temperat...

Страница 25: ...Air Handler and or heat pump operates appropriately Step 6 If utilizing the Air Handler initiate a cooling call from the room thermostat and verify that the Comfort Plus Hydronic system recognizes the COOL call Verify that the Air Handler heat pump and or air conditioner operates appropriately Step 7 Press the up arrow until the targeted brick core charge level is displayed on the control panel Wi...

Страница 26: ...40 BTU 426 500 614 160 818 880 System Dimensions W x D x H in inches 29 x 46 5 x 46 29 x 46 5 x 57 29 x 46 5 x 68 Pipe Size Water Inlet Water Outlet 1 Maximum Outlet Water Temperature 250 o F Outlet Water Temperature Selection Range 50 o F 185 o F Maximum Working Pressure PSIG 20 Minimum Flow Rate primary loop 1 GPM per 10 000 BTU of required output at 20 o F temperature rise 10 GPM maximum Approx...

Страница 27: ...c Appendix A 02 70 1B 73 22 Brick Side View 17 71 72 69 1A 2 10 3 4 5 6 8 11 12 9 7 18 19 13 16 14 15 30 31 29 28 27 26 25 33 53 52 51 50 49 48 47 45 34 35 32 46 44 43 36 37 38 42 24 23 40 39 54 55 57 60 59 20 21 41 61 64 65 63 62 56 58 66 67 68 ...

Страница 28: ...o Element Red 1041701 1041713 1041700 17 Front Air Channel 5940820 5940822 5940824 18 FrontStandoff 5940513 5940513 5940513 19 FrontGalvanized Panel 5940579 5940524 5940578 20 Upper Brick Core Temperature Sensor N A 1041725 1041725 Lower Brick Core Temperature Sensor 1041725 1041725 1041725 21 Core Blower Assembly 1041730 1041730 1041730 22 Pressure Relief Valve 1100104 1100104 1100104 23 Faceplat...

Страница 29: ... 250D Manual Reset upper 1041758 1041758 1041758 56 Left Side Exchanger Panel Inner 5940814 5940814 5940814 57 Exchanger Access Tube Cover 5940858 5940858 5940858 58 Exchanger Access Painted Panel 5940880 5940880 5940880 59 Core Blower Capacitor 1018007 1018007 1018007 60 Low Voltage Panel Assembly 1041721 1041721 1041721 61 TerminalBlock6Position 1016041 1016041 1016041 62 Electrical Panel Main B...

Страница 30: ...CK CORE L2 240 EXPANSION BOARD 1 COM COM NO RELAY 7 RELAY 8 NO L2 120 RED RELAY 5 RELAY 6 COM COM BLACK BLACK YELLOW CORE LIMIT To Optional Static Heat Recovery System COM 1 4 Amp L1 COM NO COM COM NO NO NO RELAY 2 RELAY 1 RED RELAY 3 RELAY 4 BLUE WHITE BLUE BLACK BLUE RED ORANGE To Optional Air Handler ORANGE DAMPER RESISTER RESISTOR FAN ON RELAY RELAY HEAT CALL Relays To To To 2 4 6 Relays 1 8 R...

Страница 31: ...Black White To Air Handler Pump Max 1 2 AMPS ORANGE BLUE BLACK BLUE WHITE BLUE RED RED BLACK To Optional Air Handler WHITE L2 240 RESISTER DAMPER BLOWER RESISTOR COM NO FAN ON RELAY COM NO RELAY HEAT CALL BASE IO BOARD BLACK YELLOW 5 Amp BLUE L1 L2 120 1 4 Amp NO COM NO COM 4uf EXCHANGER LIMITS WHITE MANUAL N C 225 RESET AUTO RESET N C 250 COM Cap BLACK CORE BLOWER HIGH CIRCUIT 3 CHARGE CIRCUIT 4 ...

Страница 32: ...5 RELAY 10 NO RELAY 12 COM NO COM NO COM COM RELAY 4 NO NO RED BLACK Relays 1 5 9 13 To To MANUAL Red White To Primary Loop Pump Max 1 2 AMPS Black White To Air Handler Pump Max 1 2 AMPS BLUE BLACK YELLOW EXCHANGER LIMITS 225 N C RESET AUTO RESET 250 N C 4uf HIGH BASE IO BOARD BASE IO BOARD 5 Amp 5 Amp L1 L2 120 1 4 Amp 1 4 Amp WHITE COM COM COM NO NO COM COM NO NO Cap CORE BLOWER BLACK NEUTRAL LU...

Страница 33: ...R CORE THERMOCOUPLE YELLOW RED UPPER CORE THERMOCOUPLE RED INTERNAL SYSTEM WIRING DIAGRAM LOW VOLTAGE The outdoor temperature sensor room thermostat and peak control device are connected via low voltage wiring System Low Voltage Wiring Diagram The R and C positions in the low voltage terminal strip may be used as a source of 24 VAC for powering external low voltage devices 60 VA maximum Appendix C...

Страница 34: ...k periods C1_x Specialty Timer 1 Charge Mode Specialty Applications Only C2_x Specialty Timer 2 Charge Mode Specialty Applications Only ERROR CODES The Comfort Plus Hydronic system has an on board diagnostic system to monitor various operating conditions If operating conditions move outside the normal operating range an error code is displayed on the faceplate If there are multiple errors simultan...

Страница 35: ...ors is shorted to ground the processor control board is out of calibration or the blower control circuit is connected to an improper input voltage 25 Power line carrier system is active however no good data has been received 26 Insufficient main control board memory Contact a qualified service technician 27 Insufficient permanent memory Contact a qualified service technician 28 Permanent memory ch...

Страница 36: ...id damaging them Step 7 Carefully rock the brick core Figure B to one side and lift top portion up and off the base Figure C Step 8 Move the Comfort Plus Hydronic heating system into the desired location reassemble and continue withtheinstallationinstructionsinthismanual Appendix Appendix A 11 Comfort Plus Hydronic FIGURE A FIGURE B FIGURE C Plus front saddles and back Z Bracket Limits and Right S...

Страница 37: ... L on the faceplate when in the edit mode Location Value The specific information set and stored in a location on the system s microprocessor which defines system operation A value for a spe cific location is accessed through the control panel Manual Charge Control Method of brick core charge regulation where the owner must periodically adjust the brick core temperature setting in relation to the ...

Страница 38: ...ceorpart s toSteffesCorporation ThisWarrantyisvoidiftheheatingapplianceismovedfromthepremisesinwhichitwasoriginallyinstalled This Warrantyshallnotapplytoanapplianceorpartwhichhasbeenalteredinanyrespect orimproperlyinstalled serviced orused orhasbeensubjecttoaccident negligence abuseormisuse THEABOVEWARRANTYBYSTEFFESISEXCLUSIVEANDINLIEUOFALLOTHERWARRAN TIES WHETHERWRITTENORORAL EXPRESSEDORIMPLIED I...

Отзывы: