3.2. Connecting to welding circuits
The carriage can control two torches by using the arc ignition cable plugged into the
arc ignition
socket.
To
do
this,
according to the diagram shown in Fig. 2 connect
any blue-jacketed
wire
to
any
terminal
of
the
welding circuit. Then, connect the second
blue-jacketed wire to the second terminal of the same circuit. To control the second
torch, connect the green-jacketed wires to the terminals of the second welding circuit.
Fig. 2.
Connecting the arc ignition cable to welding circuits
To make sure that
the
arc
ignition
cable
is
connected
correctly, turn on the power of
the carriage, and then set
the arc ignition
switch
to the position TEST. This should
enable the arc for a while.
blue
blue
Welding circuit 1
g
re
e
n
g
re
e
n
Welding circuit 2