Grills operated with LP (liquid propane) gas must be installed with an LP regulator Not supplied
with the unit and set to 11" water column pressure.
The gas valves used in the grills are preset at the factory for Natural Gas or Liquid Propane
operation. Please contact your dealer and use a licensed contractor or installer to convert your
grill to a different gas type.
The self-contained LP system barbeque grill is design certified to be used with a standard 20 lb,
12 1/4" diameter, 18" high cylinder with right handed connection threads and this is the
maximum size LP tank to be used. The cylinder must be marked in accordance with the latest
U.S. Department of Transportation specifications for LP gas cylinders. (DOT. CFR49 or
National Standards Of Canada CAN/CSA-B359 Cylinders, Spheres and Tubes for the
Transportation of Dangerous Goods) a Propane Tank with an ODP ) Overfill Prevention Device)
must be used at all times.
Natural Gas Requirements
Always check the Rating Plate to make sure the gas supply you are hooking up to is the gas
type the grill is manufactured for.
IMPORTANT: Never connect the grill to an unregulated gas supply.
The installation of this appliance must conform with local codes or in the absence of local codes,
to the national fuel gas code, ANSI Z223.1a-1998. Installation in Canada must be in
accordance with the standard CAN/CGA-B149.2, Propane Installation Code.
A licensed contractor or local gas company representative must perform all natural gas
connections.
Ensure that the service supplying the grill is fitted with a shut off valve conveniently positioned
near the grill and giving ease of access.
The grill must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than 0.5 psi (3.5 kPa).
The grill and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressure in excess of 0.5 psi (3.5 kPa).