fragile! When unscrewing, be extremely gentle, for you could easily break the brass fitting
and have to replace the valve).
8.
Once the orifice is removed, replace it with the new change-out orifice, (repeat for all
burners). When re-installing orifice, do not over tighten or you will strip the brass fitting.
Little pressure is needed!!!
9.
Replace burners and test for proper flame height. Flame should stand between ½” - 1” on
LOW and 1.5” - 2” on HIGH. (To adjust the LOW flame setting simply light the grill on the
LOW setting and adjust the screw which is located under the knob on the front of the valve
as seen in the diagram below.)
10. Replace burner flame tamers and cooking grills
11. If necessary, adjust the LOW flame setting screw located under the knob on the front of the
valve
NOTE: When converting to LP – remove the Natural gas Regulator that is located under the
barbecue and inline with the gas manifold and valves. When converting to Natural Gas add a
Natural gas regulator (4” Water Column Approved Natural Gas Regulator) to the gas grill either
directly on the manifold or placed in line between the Natural gas supply and the barbecue.
On the NG Regulator an arrow shows you the gas flow OR the words “In” – “Out”. If regulator is
placed the wrong way, it will not work. ( Use only a Licensed Professional when converting a
Gas Appliance)
Low flame setting
screw