5.3 DC application
The DC terminals may be used for charging 12 volt automotive-type batteries only. Output voltage
is 15-25v when current terminals are on no load.
1. Connect the charging cable to the DC terminals of the generator and then to the battery
terminals.
2. Start the engine and press the DC button and make sure the output indicator light (green)
comes on.
The DC receptacle may be used while the AC power is in use .
An overloaded DC circuit will melt down the DC circuit fuse.
If this happens, turn off the DC output and stop the engine. Open the right side cover and
you will see a fuse then replace the fuse with a new one.
To prevent the possibility of creating spark, make sure to turn off the DC output before
connect or disconnect charging cables.
Before connecting charging cable to a battery that is installed in a vehicle, disconnect
the vehicle grounded battery cable. Reconnect the vehicle's ground battery cable after the
charging cables are removed. This procedure will prevent the possibility of a short circuit
and sparks if you make accidental contact between a battery terminal and the vehicle's
frame or body.
DC botton
Right side cover
Fuse box
Fuse
DISP
ALM
DC
AC
Fig.14
When an electric motor is started, both the overload indicator (yellow) and the operation
indicator (green) may go on simultaneously. This is normal if the overload indicator (yellow)
goes off after about 4 seconds.If the overload indicator (yellow) stays on,consult your dealer.
Owner’s Manual
16
Do not attempt to start an automobile engine with the generator still connected to battery.
The generator may be damaged.
Connect the positive battery terminal to the positive charging cord. Do not reverse the
charging cables, or serious damage to the generator and/or battery may occur.
To stop the engine in an emergency, turn the engine switch OFF.
In normal use:
1. Switch off the connected equipment and pull out the inserted plug.
2. Turn off the engine switch.
3. Turn the fuel valve lever to the OFF position.
6.STOPPING THE ENGINE
3500W Digital Generator
17
7.MAINTENANCE
The purpose of the maintenance and adjustment schedule is to keep the generator
in the best operating condition.
Shut off the engine before performing any maintenance. If the engine must be run, make
sure the area is well ventilated. The exhaust contains poisonous gases.
Use our genuine parts or the equivalent. The use of replacement parts which are not of equivalent
quality may damage the generator.
7.1 Maintenance Schedule
"
NOTE: (1) Long hours of operation to determine proper maintenance.
(2) Service more frequently when used in dusty areas.
(3) These items should be serviced by an authorized dealer, unless the owner
has the proper tools and is mechanically proficient.
ITEM
REGULAR SERVICE PERIOD
(1)Perform at
every indicated month or operating hour
interval , whichever moccurs first.
EACH
USE
FIRST
MONTH
OR 20 HRS
EVERY 3
MONTHS OR
50 HRS
EVERY 6
MONTHS OR
100 HRS
EVERY YEAR
OR 300 HRS
Engine oil
Air cleaner
Spark plug
Spark arrester
Fuel sediment
cup
Valve clearance
Fuel tank and
strainer
Fuel line
Check
Change
Check
Clean
Clean-adjust
Clean
Clean
Check-adjust
Clean
Check
(2)
(3)
(3)
Every 2 year (replace if necessary) (3)
Owner’s Manual
18
7.2 Changing oil
Drain the oil while the engine is still warm to assure rapid and complete draining.
1. Open the access door.
2. Take out the oil outlet plug.
3. Remove the drain bolt, and drain the oil. Retighten the bolt securely.
4. Refill with the recommended oil and check the level.
5. Close the access door.
Fig.14
Please dispose of used motor oil in a manner that does not damage the envirnonment.
We suggest you take it in a sealed container to your local service
station for proper disposal. Do not throw it in the trash or pour it on the ground.
7.3 Air cleaner servicing
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor
malfunction, service the air cleaner regularly. Service more frequently when
operating the generator in extremely dusty areas.
Do not use gasoline or low flash point solvents for cleaning.
They are flammable and explosive under certain conditions.
Never run the generator without the air cleaner . Rapid engine wear may result.
Oil dipstick
Oil drain bolt
Upper level
Lower level
3500W Digital Generator