background image

5.3 DC application

The DC terminals may be used for charging 12 volt automotive-type batteries only. Output voltage
is 15-25v when current terminals are on no load. 
1. Connect the charging cable to the DC terminals of the generator and then to the battery  
terminals.
2. Start the engine and press the DC button and make sure the output indicator light (green) 
comes on.
The DC receptacle may be used while the AC power is in use .
An overloaded DC circuit will melt down the DC circuit fuse. 
If this happens, turn off the DC output and stop the engine. Open the right side cover and 
you will see a fuse then replace the fuse with a new one.

To prevent the possibility of creating spark, make sure to turn off the DC output before
connect or disconnect charging cables.
Before connecting charging cable to a battery that is installed in a vehicle, disconnect 
the vehicle grounded battery cable. Reconnect the vehicle's ground battery cable after the
charging cables are removed. This procedure will prevent the possibility of a short circuit 
and sparks if you make accidental contact between a battery terminal and the vehicle's 
frame or body.

DC botton

Right side cover

Fuse box

Fuse

DISP

ALM

DC

AC

Fig.14

When an electric motor is started, both the overload indicator (yellow) and the operation 
indicator (green) may go on simultaneously. This is normal if the overload indicator (yellow) 
goes off after about 4 seconds.If the overload indicator (yellow) stays on,consult your dealer.

Owner’s Manual

16

Do not attempt to start an automobile engine with the generator still connected to battery. 
The generator may be damaged.
Connect the positive battery terminal to the positive charging cord. Do not reverse the
charging cables, or serious damage to the generator and/or battery may occur.

To stop the engine in an emergency, turn the engine switch OFF.
In normal use:
1. Switch off the connected equipment and pull out the inserted plug.
2. Turn off the engine switch.
3. Turn the fuel valve lever to the OFF position.

6.STOPPING THE ENGINE

3500W Digital Generator

17

7.MAINTENANCE

The purpose of the maintenance and adjustment schedule is to keep the generator 
in the best operating condition.

Shut off the engine before performing any maintenance. If the engine must be run, make 
sure the area is well ventilated. The exhaust contains poisonous gases.

Use our genuine parts or the equivalent. The use of replacement parts which are not of equivalent

quality may damage the generator.

7.1 Maintenance Schedule

"

NOTE:  (1) Long hours of operation to determine proper maintenance.
             (2) Service more frequently when used in dusty areas.
             (3) These items should be serviced by an authorized dealer, unless the owner 

has the proper tools and is mechanically proficient.

ITEM

REGULAR SERVICE PERIOD 

(1)Perform at

every indicated month or operating hour

 interval , whichever moccurs first.

EACH
USE

FIRST
MONTH
OR 20 HRS

EVERY 3
MONTHS OR
50 HRS

EVERY 6
MONTHS OR

100 HRS

EVERY YEAR
OR 300 HRS

Engine oil

Air cleaner

Spark plug

Spark arrester

Fuel sediment
cup

Valve clearance

Fuel tank and
strainer

Fuel line

Check

Change

Check

Clean

Clean-adjust

Clean

Clean

Check-adjust

Clean

Check

(2)

(3)

(3)

Every 2 year (replace if necessary) (3)

Owner’s Manual

18

7.2 Changing oil

Drain the oil while the engine is still warm to assure rapid and complete draining.

1. Open the access door.
2. Take out the oil outlet plug.
3. Remove the drain bolt, and drain the oil. Retighten the bolt securely.
4. Refill with the recommended oil and check the level.
5. Close the access door.

Fig.14

Please dispose of used motor oil in a manner that does not damage the envirnonment. 
We suggest you take it in a sealed container to your local service 
station for proper disposal. Do not throw it in the trash or pour it on the ground.

7.3 Air cleaner servicing

A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor 
malfunction, service the air cleaner regularly. Service more frequently when 
operating the generator in extremely dusty areas.

Do not use gasoline or low flash point solvents for cleaning. 
They are flammable and explosive under certain conditions.

Never run the generator without the air cleaner . Rapid engine wear may result.

Oil dipstick

Oil drain bolt

Upper level

Lower level

3500W Digital Generator

19

Содержание SP-GG350D

Страница 1: ...onsult an authorized dealer 3500W Digital Generator 1 Our generators are designed to give safe and dependable service if operated according to instructions Read and understand the Owner s Manual before operating the generator Failure to do so could result in personal injury or equipment damage CONTENTS 1 SAFETY INSTRUCTIONS 3 2 SAFETY LABEL LOCATIONS 5 3 PRE OPERATION CHECK 8 4 STARTING THE ENGINE...

Страница 2: ...arter grip Control panel Fuel filler cap Air intake hole Front cover LCD screen Operation button Side cover 3500W Digital Generator 5 2 2 Control pannel Fig 2 Control panel ON Engine speed is kept at economical state automatically to minimize the fuel consumption while in operation This position is recommended when the output power is less than 1 kW 2 3 ECON switch When high electrical load applia...

Страница 3: ... refueling tighten the fuel filler cap securely Fig 5 Oil surface E F Loosen Tighten 3500W Digital Generator 9 Gasoline containing alcohol If you decide to use a gasoline containing alcohol gasohol be sure its octance rating is at least as high as being recommended by us There are two types of gasohol one containing ethanol and the other containing methanol Do not use gasohol that contains more th...

Страница 4: ...during a power outage and when utility power is restored the generator may explode burn or cause fires in the building s electrical system Limit operation requiring maximum power to 30 minutes For continuous operation do not exceed the rated power In either case the total wattage of all appliances connected must be considered Do not modify or use the generator for other purposes than it is intende...

Страница 5: ...tal Generator 17 7 MAINTENANCE The purpose of the maintenance and adjustment schedule is to keep the generator in the best operating condition Shut off the engine before performing any maintenance If the engine must be run make sure the area is well ventilated The exhaust contains poisonous gases Use our genuine parts or the equivalent The use of replacement parts which are not of equivalent quali...

Страница 6: ...cover and tighten the cover screw 10 Close the access door Plug gap The spark plug must be securely tightened An improperly tightened spark plug can become very hot and possibly damage the generator Never use a spark plug with an improper heat range 3500W Digital Generator 21 7 5 Spark arrester maintenance If the generator has been running the muffler will be very hot Allow it to cool before proce...

Страница 7: ...cuit Switch on the DC output Replace the DC circuit fuse Take the generator to an authorized dealer NO YES NO Is the operation indicator light ON Is the short circuit indicator light ON Check the electrical appliance or equipment for any defects Take the generator to an authorized dealer Take the generator to an authorized dealer Replace the electrical appliance or equipment Take the electrical ap...

Страница 8: ...r 27 APG3104 28 BOLD Fuel tank 28 APG3104 29 BOLD Bolt 29 APG3104 30 BOLD Handle 30 APG3104 31 BOLD Bolt 31 APG3104 32 BOLD Sealing ring 32 APG3104 33 BOLD Start grip 33 APG3104 34 BOLD Bolt 34 APG3104 35 BOLD Ring cover 35 APG3104 36 BOLD Frame 36 APG3104 37 BOLD Bolt 37 APG3104 38 BOLD Fuel switch 38 APG3104 39 BOLD Oil alert lamp 39 APG3104 40 BOLD Engine switch 40 Owner s Manual 30 APA Part No...

Страница 9: ...t costs if any must be paid by the purchaser If the purchaser does not receive satisfactory results form the Authorized Warranty Service Center the purchaser should contact Steele toll free 888 896 6881 THIS WARRANTY DOES NOT COVER Merchandise sold as reconditioned used as rental equipment or floor or display models Merchandise that has become damaged or inoperative because of ordinary wear misuse...